1 From the Department of Radiology, Vancouver General Hospital and University of British Columbia, Canada (N.T.); and the Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, 565-0871, Japan (N.T., N.M., M.M., T.J., T.K., O.H., S.H., S.Y., H.N.). Received November 3, 1999; revision requested December 10; final revision received March 31, 2000; accepted April 4. Address correspondence to N.T. (e-mail: tomiyama@radiol.med.osaka-u.ac.jp).
A respiratory gating technique was developed to allow computed tomographyguided needle biopsy of small pulmonary nodules. Twenty-three pulmonary nodules less than 15 mm in diameter underwent biopsy with the use of this technique. There were 14 true-positive, eight true-negative, and one false-negative result (diagnostic accuracy, 96%). The diagnostic accuracy for small nodules without this technique in a historical control was 69% (P < .05).
Index terms: Biopsies, technology, 60.126 Computed tomography (CT), guidance, 60.12111, 60.12118 Interventional procedures, technology Lung, biopsy, 60.126 Lung, nodule, 60.314, 60.321 Lung neoplasms, 60.314, 60.321
This article has been cited by other articles:
![]() |
H. Matsuguma, R. Nakahara, T. Kondo, Y. Kamiyama, K. Mori, and K. Yokoi Risk of Pleural Recurrence After Needle Biopsy in Patients With Resected Early Stage Lung Cancer Ann. Thorac. Surg., December 1, 2005; 80(6): 2026 - 2031. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. K. Carlson, J. P. Felmlee, C. E. Bender, R. L. Ehman, K. L. Classic, T. L. Hoskin, W. S. Harmsen, and H. H. Hu CT Fluoroscopy-guided Biopsy of the Lung or Upper Abdomen with a Breath-hold Monitoring and Feedback System: A Prospective Randomized Controlled Clinical Trial Radiology, November 1, 2005; 237(2): 701 - 708. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. K. Carlson, J. P. Felmlee, C. E. Bender, R. L. Ehman, K. L. Classic, H. H. Hu, and T. L. Hoskin Intermittent-Mode CT Fluoroscopy-guided Biopsy of the Lung or Upper Abdomen with Breath-hold Monitoring and Feedback: System Development and Feasibility Radiology, December 1, 2003; 229(3): 906 - 912. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Wallace, S. Krishnamurthy, L. D. Broemeling, S. Gupta, K. Ahrar, F. A. Morello Jr, and M. E. Hicks CT-guided Percutaneous Fine-Needle Aspiration Biopsy of Small (<=1-cm) Pulmonary Lesions Radiology, December 1, 2002; 225(3): 823 - 828. [Abstract] [Full Text] [PDF] |
||||
![]() |
R.J. van Klaveren, J.D.F. Habbema, J.H. Pedersen, H.J. de Koning, M. Oudkerk, and H.C. Hoogsteden Lung cancer screening by low-dose spiral computed tomography Eur. Respir. J., November 1, 2001; 18(5): 857 - 866. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |