Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hidajat, N.
Right arrow Articles by Felix, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hidajat, N.
Right arrow Articles by Felix, R.
(Radiology. 2001;218:395-401.)
© RSNA, 2001


Medical Physics

Survey of Conventional and Spiral CT Doses1

Nico Hidajat, MD, Martin Wolf, PhD, Albert Nunnemann, PhD, Peggy Liersch, MD, Bernhard Gebauer, MD, Ulf Teichgräber, MD, Ralf J. Schröder, MD and Roland Felix, MD

1 From the Department of Radiology (Strahlenklinik und Poliklinik), Charité, Virchow-Clinic of the Humboldt-University, Augustenburger Platz 1, 13353 Berlin, Germany (N.H., M.W., P.L., B.G., U.T., R.J.S., R.F.); and the Technical Supervisory Authority, Berlin, Germany (A.N.). Received November 24, 1999; revision requested January 21, 2000; final revision received June 16; accepted June 28. Address correspondence to N.H. (e-mail: hidajat@telda.net).

PURPOSE: To investigate the radiation dose for conventional computed tomography (CT) and spiral CT during different CT examinations at various hospitals and practices.

MATERIALS AND METHODS: CT dose index with an active length of 15 cm was measured in 16 different types of CT scanners by using ionization chamber dosimetry. Twenty-six holders (one who has legal responsibility under national law for a radiologic installation) operating a total of seven conventional and 20 spiral CT scanners were asked for their standard parameters for various CT examinations. Weighted CT dose index and dose-length product were determined for each examination.

RESULTS: For most examinations, the tube current time product was significantly higher for conventional CT than for spiral CT (.002 <= P <= .05). The ratio of section distance to section thickness for conventional CT was significantly lower than the pitch for spiral CT (.001 <= P <= .05). The weighted CT dose index and dose-length product for spiral CT were about half of those for conventional CT. The third quartiles for weighted CT dose index and dose-length product for spiral CT were much lower than those recommended as reference doses.

CONCLUSION: CT examinations with conventional CT scanners are often performed with unnecessarily high radiation dose. For the establishment of reference doses, the radiation dose with spiral CT scanners should be taken into account.

Index terms: Computed tomography (CT), radiation exposure, **.121112, **.12112, **.12115 • Dosimetry, **.12111, **.12112, **.12115 • Radiations, exposure to patients and personnel, **.12111, **.12112, **.12115 • Radiations, measurement, **.12111, **.12112, **.12115




This article has been cited by other articles:


Home page
RadiologyHome page
V. Tsapaki, J. E. Aldrich, R. Sharma, M. A. Staniszewska, A. Krisanachinda, M. Rehani, A. Hufton, C. Triantopoulou, P. N. Maniatis, J. Papailiou, et al.
Dose Reduction in CT while Maintaining Diagnostic Confidence: Diagnostic Reference Levels at Routine Head, Chest, and Abdominal CT--IAEA-coordinated Research Project
Radiology, September 1, 2006; 240(3): 828 - 834.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Das, A. H. Mahnken, G. Muhlenbruch, A. Stargardt, C. Weiss, D.-A. Sennst, T. G. Flohr, R. W. Gunther, and J. E. Wildberger
Individually Adapted Examination Protocols for Reduction of Radiation Exposure for 16-MDCT Chest Examinations
Am. J. Roentgenol., May 1, 2005; 184(5): 1437 - 1443.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Mahesh, J. C. Scatarige, J. Cooper, and E. K. Fishman
Dose and Pitch Relationship for a Particular Multislice CT Scanner
Am. J. Roentgenol., December 1, 2001; 177(6): 1273 - 1275.
[Abstract] [Full Text] [PDF]