Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hennemeyer, C. T.
Right arrow Articles by Derdeyn, C. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hennemeyer, C. T.
Right arrow Articles by Derdeyn, C. P.
(Radiology. 2001;219:732-737.)
© RSNA, 2001


Experimental Studies

In Vitro Evaluation of Platinum Guglielmi Detachable Coils at 3 T with a Porcine Model: Safety Issues and Artifacts1

Charles T. Hennemeyer, BS, Karsten Wicklow, PhD, David A. Feinberg, MD, PhD and Colin P. Derdeyn, MD

1 From the Neuroradiology Section (D.A.F., C.P.D.) and Neuroimaging Laboratory (C.T.H., C.P.D.), Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110; and Research and Development Division, Siemens Medical Systems, Iselin, NJ (K.W.). Received August 10, 2000; revision requested October 3; revision received November 16; accepted December 11. Address correspondence to C.P.D. (e-mail: derdeync@mir.wustl.edu).

PURPOSE: To evaluate safety-related issues and imaging artifacts of Guglielmi detachable coils in vitro with 3-T magnetic resonance (MR) imaging.

MATERIALS AND METHODS: Two aneurysm models were constructed: one from porcine carotid artery and the other from a pharmaceutical capsule. Both were filled with Guglielmi detachable coils. The models were tested with a 3-T MR imager for heating, deflection, and imaging artifact. Testing for heating and deflection was performed (a) at static points both inside and outside the bore, (b) during movement into the imager, and (c) during clinical imaging sequences.

RESULTS: No change in temperature was measured during movement into the imager bore or at different points within the bore. No differences in heating from radio-frequency energy were found between aneurysm models and controls. Similarly, no evidence of deflection of the coil mass (capsule model) was found. Minor susceptibility artifacts were found in the readout direction during gradient-echo sequences. Magnetic field mapping showed no induced field inhomogeneity.

CONCLUSION: MR imaging at field strengths of 3 T in patients with aneurysms treated with Guglielmi detachable coils is safe. Imaging artifacts are likely to be minimal.

Index terms: Aneurysm, cerebral, 17.73 • Head, MR, 10.121411, 10.121412, 10.12142 • Magnetic resonance (MR), safety, 10.121411, 10.121412, 10.12142 • Radiology and radiologists, iatrogenic injury




This article has been cited by other articles:


Home page
CirculationHome page
G. N. Levine, A. S. Gomes, A. E. Arai, D. A. Bluemke, S. D. Flamm, E. Kanal, W. J. Manning, E. T. Martin, J. M. Smith, N. Wilke, et al.
Safety of Magnetic Resonance Imaging in Patients With Cardiovascular Devices: An American Heart Association Scientific Statement From the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: Endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance
Circulation, December 11, 2007; 116(24): 2878 - 2891.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
V. Costalat, E. Lebars, L. Sarry, A. Defasque, E. Barbotte, H. Brunel, G. Bourbotte, and A. Bonafe
In Vitro Evaluation of 2D-Digital Subtraction Angiography versus 3D-Time-of-Flight in Assessment of Intracranial Cerebral Aneurysm Filling after Endovascular Therapy
AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 177 - 184.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C. B. L. M. Majoie, M. E. Sprengers, W. J. J. van Rooij, C. Lavini, M. Sluzewski, J. C. van Rijn, and G. J. den Heeten
MR Angiography at 3T versus Digital Subtraction Angiography in the Follow-up of Intracranial Aneurysms Treated with Detachable Coils
AJNR Am. J. Neuroradiol., June 1, 2005; 26(6): 1349 - 1356.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
F. G. Shellock, M. Gounis, and A. Wakhloo
Detachable Coil for Cerebral Aneurysms: In Vitro Evaluation of Magnetic Field Interactions, Heating, and Artifacts at 3T
AJNR Am. J. Neuroradiol., February 1, 2005; 26(2): 363 - 366.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. Nehra, C. J. Moran, D. T. Cross III, and C. P. Derdeyn
MR Safety and Imaging of Neuroform Stents at 3T
AJNR Am. J. Neuroradiol., October 1, 2004; 25(9): 1476 - 1478.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. G. Shellock and J. V. Crues
MR Procedures: Biologic Effects, Safety, and Patient Care
Radiology, September 1, 2004; 232(3): 635 - 652.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
F. G. Shellock, J. A. Tkach, P. M. Ruggieri, T. J. Masaryk, and P. A. Rasmussen
Aneurysm Clips: Evaluation of Magnetic Field Interactions and Translational Attraction by Use of "Long-Bore" and "Short-Bore" 3.0-T MR Imaging Systems
AJNR Am. J. Neuroradiol., March 1, 2003; 24(3): 463 - 471.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2001 by the Radiological Society of North America.