Technical Developments |
1 From the Department of Radiology, Northwestern University Medical School, 448 E Ontario St, Suite 700, Chicago, IL 60611 (J.C.C., D.L., S.P., J.P.F.), and Siemens Medical Systems, Iselin, NJ (O.S., J.B.). From the 1999 RSNA scientific assembly. Received July 17, 2000; revision requested August 21; revision received November 7; accepted November 20. Address correspondence to J.C.C. (e-mail: jcarr@radiology.nwu.edu).
In five healthy subjects and 18 patients, cine magnetic resonance (MR) imaging of the heart was performed with a true fast imaging with steady-state precession (FISP) sequence. Results were compared both quantitatively and qualitatively with those at cine fast low-angle shot (FLASH) MR imaging. The blood-myocardial contrast-to-noise ratio (CNR) was 2.0 times higher and the normalized (for measurement time and pixel size) blood-myocardial CNR was 4.0 times higher for true FISP compared with FLASH MR imaging. Qualitative scores for image quality were significantly higher with true FISP MR imaging. Segmented cine true FISP MR imaging generated high-contrast MR images of the heart in healthy subjects and in patients with heart disease and produced image quality superior to that with cine FLASH MR imaging.
Index terms: Heart, MR, 51.121412 Magnetic resonance (MR), cine study Magnetic resonance (MR), image processing Magnetic resonance (MR), technology, 51.121412
This article has been cited by other articles:
![]() |
H. V. Dinh, J. Alvergue, J. Sayre, J. S. Child, V. S. Deshpande, G. Laub, and J. P. Finn Isovolumic Cardiac Contraction on High-Temporal-Resolution Cine MR Images: Study in Heart Failure Patients and Healthy Volunteers Radiology, August 1, 2008; 248(2): 458 - 465. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Carlsson, N. F. Osman, P. C. Ursell, A. J. Martin, and M. Saeed Quantitative MR measurements of regional and global left ventricular function and strain after intramyocardial transfer of VM202 into infarcted swine myocardium Am J Physiol Heart Circ Physiol, August 1, 2008; 295(2): H522 - H532. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Saremi, J. D. Grizzard, and R. J. Kim Optimizing Cardiac MR Imaging: Practical Remedies for Artifacts RadioGraphics, July 1, 2008; 28(4): 1161 - 1187. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Francois, D. Tuite, V. Deshpande, R. Jerecic, P. Weale, and J. C. Carr Unenhanced MR Angiography of the Thoracic Aorta: Initial Clinical Evaluation Am. J. Roentgenol., April 1, 2008; 190(4): 902 - 906. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. W. Goldfarb, S. Arnold, and J. Han Recent Myocardial Infarction: Assessment with Unenhanced T1-weighted MR Imaging Radiology, October 1, 2007; 245(1): 245 - 250. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Marui, K. Tambara, E. Tadamura, Y. Saji, N. Sasahashi, T. Ikeda, T. Nishina, and M. Komeda A novel approach to restore atrial function after the maze procedure in patients with an enlarged left atrium Eur. J. Cardiothorac. Surg., August 1, 2007; 32(2): 308 - 312. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Fenchel, R. Saleh, H. Dinh, M. H. Lee, K. Nael, M. Krishnam, S. G. Ruehm, S. Miller, J. Child, and J. P. Finn Juvenile and Adult Congenital Heart Disease: Time-resolved 3D Contrast-enhanced MR Angiography Radiology, August 1, 2007; 244(2): 399 - 410. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Groves, W. Bireley, K. Dill, T. J. Carroll, and J. C. Carr Quantitative Analysis of ECG-Gated High-Resolution Contrast-Enhanced MR Angiography of the Thoracic Aorta Am. J. Roentgenol., February 1, 2007; 188(2): 522 - 528. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Maceira, S. K. Prasad, M. Khan, and D. J. Pennell Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance Eur. Heart J., December 1, 2006; 27(23): 2879 - 2888. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Finn, K. Nael, V. Deshpande, O. Ratib, and G. Laub Cardiac MR Imaging: State of the Technology. Radiology, November 1, 2006; 241(2): 338 - 354. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Finn, R. Saleh, S. Thesen, S. G. Ruehm, M. H. Lee, J. Grinstead, J. S. Child, and G. Laub MR Imaging with Remote Control: Feasibility Study in Cardiovascular Disease Radiology, November 1, 2006; 241(2): 528 - 537. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Mutlu, C. Basekim, E. Silit, Z. Pekkafali, E. Ozturk, B. Karaman, M. Kantarci, E. Kizilkaya, and F. Karsli Gadolinium-enhanced 3D MR angiography of pulmonary hypoplasia and aplasia. Am. J. Roentgenol., August 1, 2006; 187(2): 398 - 403. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. L. Raff, W. W. O'Neill, R. E. Gentry, A. Dulli, K. G. Bis, A. N. Shetty, and J. A. Goldstein Microvascular Obstruction and Myocardial Function after Acute Myocardial Infarction: Assessment by Using Contrast-enhanced Cine MR Imaging. Radiology, August 1, 2006; 240(2): 529 - 536. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Jackson, S Stivaros, and E A Moore Advances in magnetic resonance imaging Imaging, June 1, 2006; 18(2): 97 - 109. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Pedrosa, M. Morrin, L. Oleaga, J. Baptista, and N. M. Rofsky Is True FISP Imaging Reliable in the Evaluation of Venous Thrombosis? Am. J. Roentgenol., December 1, 2005; 185(6): 1632 - 1640. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Amano, S. Kumita, M. Takayama, and T. Kumazaki Comparison of Contrast-Enhanced MRI with Iodine-123 BMIPP for Detection of Myocardial Damage in Hypertrophic Cardiomyopathy Am. J. Roentgenol., August 1, 2005; 185(2): 312 - 318. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. Shea, D. S. Fieno, B. E. Schirf, X. Bi, J. Huang, R. A. Omary, and D. Li T2-prepared Steady-State Free Precession Blood Oxygen Level-Dependent MR Imaging of Myocardial Perfusion in a Dog Stenosis Model Radiology, August 1, 2005; 236(2): 503 - 509. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Tadamura, M. Yamamuro, S. Kubo, S. Kanao, T. Saga, M. Harada, M. Ohba, R. Hosokawa, T. Kimura, T. Kita, et al. Effectiveness of Delayed Enhanced MRI for Identification of Cardiac Sarcoidosis: Comparison with Radionuclide Imaging Am. J. Roentgenol., July 1, 2005; 185(1): 110 - 115. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Kacere, M. Pereyra, M. A. Nemeth, R. Muthupillai, and S. D. Flamm Quantitative Assessment of Left Ventricular Function: Steady-State Free Precession MR Imaging with or without Sensitivity Encoding Radiology, June 1, 2005; 235(3): 1031 - 1035. [Abstract] [Full Text] [PDF] |
||||
![]() |
N I Stauder, A M Scheule, U Hahn, M Fenchel, F S Eckstein, U Kramer, C D Claussen, and S Miller Perioperative monitoring of flow and patency in native and grafted internal mammary arteries using a combined MR protocol Br. J. Radiol., April 1, 2005; 78(928): 292 - 298. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Berg, V. L. Sorrell, K. B. Kern, R. W. Hilwig, M. I. Altbach, M. M. Hayes, K. A. Bates, and G. A. Ewy Magnetic Resonance Imaging During Untreated Ventricular Fibrillation Reveals Prompt Right Ventricular Overdistention Without Left Ventricular Volume Loss Circulation, March 8, 2005; 111(9): 1136 - 1140. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Yamamuro, E. Tadamura, S. Kubo, H. Toyoda, T. Nishina, M. Ohba, R. Hosokawa, T. Kimura, N. Tamaki, M. Komeda, et al. Cardiac Functional Analysis with Multi-Detector Row CT and Segmental Reconstruction Algorithm: Comparison with Echocardiography, SPECT, and MR Imaging Radiology, February 1, 2005; 234(2): 381 - 390. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Kramer The comprehensive approach to ischemic heart disease by cardiovascular magnetic resonance imaging: Are we there yet? J. Am. Coll. Cardiol., December 7, 2004; 44(11): 2182 - 2184. [Full Text] [PDF] |
||||
![]() |
A. Gupta, V. S. Lee, Y.-C. Chung, J. S. Babb, and O. P. Simonetti Myocardial Infarction: Optimization of Inversion Times at Delayed Contrast-enhanced MR Imaging Radiology, December 1, 2004; 233(3): 921 - 926. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Fieno, S. M. Shea, Y. Li, K. R. Harris, J. P. Finn, and D. Li Myocardial Perfusion Imaging Based on the Blood Oxygen Level-Dependent Effect Using T2-Prepared Steady-State Free-Precession Magnetic Resonance Imaging Circulation, September 7, 2004; 110(10): 1284 - 1290. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. R. Edelman Contrast-enhanced MR Imaging of the Heart: Overview of the Literature Radiology, September 1, 2004; 232(3): 653 - 668. [Abstract] [Full Text] [PDF] |
||||
![]() |
C Kupfahl, M Honold, G Meinhardt, H Vogelsberg, A Wagner, H Mahrholdt, and U Sechtem Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques Heart, August 1, 2004; 90(8): 893 - 901. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. W. Bowman and S. J. Kovacs Left atrial conduit volume is generated by deviation from the constant-volume state of the left heart: a combined MRI-echocardiographic study Am J Physiol Heart Circ Physiol, June 1, 2004; 286(6): H2416 - H2424. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Kim, W. D. Gilson, C. M. Kramer, and F. H. Epstein Myocardial Tissue Tracking with Two-dimensional Cine Displacement-encoded MR Imaging: Development and Initial Evaluation Radiology, March 1, 2004; 230(3): 862 - 871. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Amano, M. Takayama, M. Amano, and T. Kumazaki MRI of Cardiac Morphology and Function After Percutaneous Transluminal Septal Myocardial Ablation for Hypertrophic Obstructive Cardiomyopathy Am. J. Roentgenol., February 1, 2004; 182(2): 523 - 527. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Li, P. Storey, Q. Chen, B. S. Y. Li, P. V. Prasad, and R. R. Edelman Dark Flow Artifacts with Steady-State Free Precession Cine MR Technique: Causes and Implications for Cardiac MR Imaging Radiology, February 1, 2004; 230(2): 569 - 575. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. Shors, C. W. Fung, C. J. Francois, J. P. Finn, and D. S. Fieno Accurate Quantification of Right Ventricular Mass at MR Imaging by Using Cine True Fast Imaging with Steady-State Precession: Study in Dogs Radiology, February 1, 2004; 230(2): 383 - 388. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Francois, D. S. Fieno, S. M. Shors, and J. P. Finn Left Ventricular Mass: Manual and Automatic Segmentation of True FISP and FLASH Cine MR Images in Dogs and Pigs Radiology, February 1, 2004; 230(2): 389 - 395. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, D. Resnick, S. S. Tiu, J. J. Sanger, C. A. Nazzaro, G. M. Israel, and O. P. Simonetti MR Imaging Evaluation of Myocardial Viability in the Setting of Equivocal SPECT Results with 99mTc Sestamibi Radiology, January 1, 2004; 230(1): 191 - 197. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. Shors, W. G. Cotts, B. Pavlovic-Surjancev, C. J. Francois, M. Gheorghiade, and J. P. Finn Heart Failure: Evaluation of Cardiopulmonary Transit Times with Time-resolved MR Angiography Radiology, December 1, 2003; 229(3): 743 - 748. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. W. Bowman and S. J. Kovacs Assessment and consequences of the constant-volume attribute of the four-chambered heart Am J Physiol Heart Circ Physiol, November 1, 2003; 285(5): H2027 - H2033. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Spuentrup, J. Schroeder, A. H. Mahnken, T. Schaeffter, R. M. Botnar, H. P. Kuhl, P. Hanrath, R. W. Gunther, and A. Buecker Quantitative Assessment of Left Ventricular Function with Interactive Real-Time Spiral and Radial MR Imaging Radiology, June 1, 2003; 227(3): 870 - 876. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Baskaran, F. S. Pereles, E. J. Russell, S. A. Georganos, A. Shaibani, K. A. Spero, E. A. Krupinski, A. Zhang, and J. P. Finn Myelographic MR Imaging of the Cervical Spine with a 3D True Fast Imaging with Steady-State Precession Technique: Initial Experience Radiology, May 1, 2003; 227(2): 585 - 592. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. McCarthy, S. M. Shea, V. S. Deshpande, J. D. Green, F. S. Pereles, J. C. Carr, J. P. Finn, and D. Li Coronary MR Angiography: True FISP Imaging Improved by Prolonging Breath Holds with Preoxygenation in Healthy Volunteers Radiology, April 1, 2003; 227(1): 283 - 288. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Plein, T. R. Jones, J. P. Ridgway, and M. U. Sivananthan Three-Dimensional Coronary MR Angiography Performed with Subject-Specific Cardiac Acquisition Windows and Motion-Adapted Respiratory Gating Am. J. Roentgenol., February 1, 2003; 180(2): 505 - 512. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Choudhury, H. Mahrholdt, A. Wagner, K. M. Choi, M. D. Elliott, F. J. Klocke, R. O. Bonow, R. M. Judd, and R. J. Kim Myocardial scarring in asymptomatic or mildly symptomatic patients with hypertrophic cardiomyopathy J. Am. Coll. Cardiol., December 18, 2002; 40(12): 2156 - 2164. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Gaba, R. C. Carlos, W. J. Weadock, G. P. Reddy, M. B. Sneider, and P. N. Cascade Cardiovascular MR Imaging: Technique Optimization and Detection of Disease in Clinical Practice RadioGraphics, November 1, 2002; 22(6): e6 - e6. [Abstract] [Full Text] |
||||
![]() |
S. Plein, J. P. Ridgway, T. R. Jones, T. N. Bloomer, and M. U. Sivananthan Coronary Artery Disease: Assessment with a Comprehensive MR Imaging Protocol—Initial Results Radiology, October 1, 2002; 225(1): 300 - 307. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. G. Rehwald, R. J. Kim, O. P. Simonetti, G. Laub, and R. M. Judd Theory of High-Speed MR Imaging of the Human Heart with the Selective Line Acquisition Mode Radiology, August 1, 2001; 220(2): 540 - 547. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Shankaranarayanan, O. P. Simonetti, G. Laub, J. S. Lewin, and J. L. Duerk Segmented k-Space and Real-Time Cardiac Cine MR Imaging with Radial Trajectories Radiology, December 1, 2001; 221(3): 827 - 836. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, D. Resnick, J. M. Bundy, O. P. Simonetti, P. Lee, and J. C. Weinreb Cardiac Function: MR Evaluation in One Breath Hold with Real-time True Fast Imaging with Steady-State Precession Radiology, March 1, 2002; 222(3): 835 - 842. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Miller, O. P. Simonetti, J. Carr, U. Kramer, and J. P. Finn MR Imaging of the Heart with Cine True Fast Imaging with Steady-State Precession: Influence of Spatial and Temporal Resolutions on Left Ventricular Functional Parameters Radiology, April 1, 2002; 223(1): 263 - 269. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. S. Pereles, R. M. McCarthy, V. Baskaran, J. C. Carr, V. Kapoor, E. A. Krupinski, and J. P. Finn Thoracic Aortic Dissection and Aneurysm: Evaluation with Nonenhanced True FISP MR Angiography in Less than 4 Minutes Radiology, April 1, 2002; 223(1): 270 - 274. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |