Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tillich, M.
Right arrow Articles by Rubin, G. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tillich, M.
Right arrow Articles by Rubin, G. D.
(Radiology. 2001;220:475-483.)
© RSNA, 2001


Vascular and Interventional Radiology

Prediction of Aortoiliac Stent-Graft Length: Comparison of Measurement Methods1

Manfred Tillich, MD, Bradley B. Hill, MD, David S. Paik, MS, Kerstin Petz, RT, Sandy Napel, PhD, Christopher K. Zarins, MD and Geoffrey D. Rubin, MD

1 From the Departments of Radiology (M.T., D.S.P., K.P., S.N., G.D.R.) and Vascular Surgery (B.B.H., C.K.Z.), Stanford University School of Medicine, S-072B, 300 Pasteur Dr, Stanford, CA 94305-5105. Received November 21, 2000; revision requested January 4, 2001; final revision received February 9; accepted February 26. Address correspondence to G.D.R. (e-mail: grubin@stanford.edu).

PURPOSE: To determine the accuracy of helical computed tomography (CT), projectional angiography derived from CT angiography, and intravascular ultrasonographic withdrawal (IUW) length measurements for predicting appropriate aortoiliac stent-graft length.

MATERIALS AND METHODS: Helical CT data from 33 patients were analyzed before and after endovascular repair of abdominal aortic aneurysm (Aneuryx graft, n = 31; Excluder graft, n = 2). The aortoiliac length of the median luminal centerline (MLC) and the shortest path (SP) that remained at least one common iliac arterial radius away from the vessel wall were calculated. Conventional angiographic measurements were simulated from CT data as the length of the three-dimensional MLC projected onto four standard viewing planes. These predeployment lengths and IUW length, available in 24 patients, were compared with the aortoiliac arterial length after stent-graft deployment.

RESULTS: The mean error values of SP, MLC, the maximum projected MLC, and IUW were -2.1 mm ± 4.6 (SD) (P = .013), 9.8 mm ± 6.8 (P < .001), -5.2 mm ± 7.8 (P < .001), and -14.1 mm ± 9.3 (P < .001), respectively. The preprocedural prediction of the postprocedural aortoiliac length with the SP was significantly more accurate than that with the MLC (P < .001), maximum projected MLC (P < .001), and IUW (P < .001).

CONCLUSION: The shortest aortoiliac path length maintaining at least one radius distance from the vessel wall most accurately enabled stent-graft length prediction for 31 AneuRx and two Excluder stent-grafts.

Index terms: Aneurysm, aortic, 89.73, 98.73 • Aorta, CT, 89.12912, 89.12915 • Aorta, grafts and prostheses, 89.1268, 98.1268 • Aorta, interventional procedures, 89.1268







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2001 by the Radiological Society of North America.