Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2203001129
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mao, S.
Right arrow Articles by Budoff, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mao, S.
Right arrow Articles by Budoff, M. J.
(Radiology. 2001;220:707-711.)
© RSNA, 2001


Cardiac Imaging

Effect of Electrocardiogram Triggering on Reproducibility of Coronary Artery Calcium Scoring1

Songshou Mao, MD, Hamid Bakhsheshi, RT, Bin Lu, MD, Steve C. K. Liu, MD, Ronald J. Oudiz, MD and Matthew J. Budoff, MD

1 From the Harbor-UCLA Research and Education Institute, 1124 W Carson St, RB-2, Torrance, CA 90502. Received June 20, 2000; revision requested August 18; final revision received March 8, 2001; accepted March 16. Address correspondence to M.J.B. (e-mail: mbudoff@rei.edu).

PURPOSE: To test the hypothesis that computed tomographic (CT) scanning during early rather than middle diastole can significantly reduce the interscan variability of coronary artery calcium (CAC) scores.

MATERIALS AND METHODS: Five hundred thirty-eight patients were initially enrolled; 282 of them were found to have CAC at electron-beam CT and underwent repeat scanning to measure interscan variability with different electrocardiogram (ECG) triggers. Eight patients were excluded owing to respiratory motion; thus, 274 asymptomatic patients were examined. Patients were randomly assigned to different ECG trigger interval groups: 40% (group 1), 50% (group 2), 60% (group 3), and 80% (group 4). Patients in whom more than one-third of sections had greater than 10% ECG trigger variability were classified in the untriggered group (group 5). Interscan variation was compared among all five groups.

RESULTS: Interscan variabilities in CAC groups 1–5 were 11.5%, 15.3%, 20.3%, 17.4%, and 33.1%, respectively, for total calcium area, and 15.0%, 23.3%, 25.6%, 24.0%, and 42.4%, respectively, for total calcium score. CAC score variability was reduced by 34%; and calcium area variability, by 38% in group 1, as compared with the reduced variabilities in group 4 (P < .01 for both measures). Breath holding was adequate in 812 cases, and ECG triggering was correct in 790 of cases.

CONCLUSION: Study results strongly support the use of an ECG trigger of 40% rather than 80% of the R-R interval in electron-beam CT calcium studies.

Index terms: Computed tomography (CT), electron beam, 548.12111, 548.12116, 548.12119 • Coronary vessels, calcification, 54.812 • Coronary vessels, CT, 548.12111, 548.12116, 548.12119 • Coronary vessels, stenosis or obstruction, 548.76, 548.812




This article has been cited by other articles:


Home page
RadiologyHome page
A. Rutten, I. Isgum, and M. Prokop
Coronary Calcification: Effect of Small Variation of Scan Starting Position on Agatston, Volume, and Mass Scores
Radiology, December 1, 2007; 246(1): 90 - 98.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
O. Leontiev and T. J. Dubinsky
CT-Based Calcium Scoring to Screen for Coronary Artery Disease: Why Aren't We There Yet?
Am. J. Roentgenol., November 1, 2007; 189(5): 1061 - 1063.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Greenland, R. O. Bonow, B. H. Brundage, M. J. Budoff, M. J. Eisenberg, S. M. Grundy, M. S. Lauer, W. S. Post, P. Raggi, R. F. Redberg, et al.
ACCF/AHA 2007 Clinical Expert Consensus Document on Coronary Artery Calcium Scoring By Computed Tomography in Global Cardiovascular Risk Assessment and in Evaluation of Patients With Chest Pain: A Report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) Developed in Collaboration With the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography
J. Am. Coll. Cardiol., January 23, 2007; 49(3): 378 - 402.
[Full Text] [PDF]


Home page
CirculationHome page
M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A.C. Lima, D. J. Rader, G. D. Rubin, et al.
Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology
Circulation, October 17, 2006; 114(16): 1761 - 1791.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Horiguchi, H. Yamamoto, N. Hirai, Y. Akiyama, C. Fujioka, K. Marukawa, H. Fukuda, and K. Ito
Variability of repeated coronary artery calcium measurements on low-dose ECG-gated 16-MDCT.
Am. J. Roentgenol., July 1, 2006; 187(1): W1 - W6.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
M. Budoff
Aged Garlic Extract Retards Progression of Coronary Artery Calcification,
J. Nutr., March 1, 2006; 136(3): 741S - 744S.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. E. Clouse, J. Chen, H. M. Krumholz, M. E. Clouse, J. Chen, and H. M. Krumholz
Noninvasive Screening for Coronary Artery Disease With Computed Tomography Is Useful
Circulation, January 3, 2006; 113(1): 125 - 146.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. J. W. Sandstede, J. Stoffels, F. Wendel, C. Ritter, M. Beer, and D. Hahn
Different Reconstruction Intervals for Exclusion of Coronary Artery Calcifications by Retrospectively Gated MDCT
Am. J. Roentgenol., January 1, 2006; 186(1): 193 - 197.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. B. Sevrukov, J. M. Bland, and G. T. Kondos
Serial Electron Beam CT Measurements of Coronary Artery Calcium: Has Your Patient's Calcium Score Actually Changed?
Am. J. Roentgenol., December 1, 2005; 185(6): 1546 - 1553.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Horiguchi, Y. Shen, Y. Akiyama, N. Hirai, K. Sasaki, M. Ishifuro, T. Nakanishi, and K. Ito
Electron Beam CT Versus 16-MDCT on the Variability of Repeated Coronary Artery Calcium Measurements in a Variable Heart Rate Phantom
Am. J. Roentgenol., October 1, 2005; 185(4): 995 - 1000.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. C. Detrano, M. Anderson, J. Nelson, N. D. Wong, J. J. Carr, M. McNitt-Gray, and D. E. Bild
Coronary Calcium Measurements: Effect of CT Scanner Type and Calcium Measure on Rescan Reproducibility--MESA Study
Radiology, August 1, 2005; 236(2): 477 - 484.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Horiguchi, H. Yamamoto, Y. Akiyama, N. Hirai, K. Marukawa, H. Fukuda, and K. Ito
Variability of Repeated Coronary Artery Calcium Measurements by 16-MDCT with Retrospective Reconstruction
Am. J. Roentgenol., June 1, 2005; 184(6): 1917 - 1923.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Schlosser, P. Hunold, A. Schmermund, H. Kuhl, K.-U. Waltering, J. F. Debatin, and J. Barkhausen
Coronary Artery Calcium Score: Influence of Reconstruction Interval at 16-Detector Row CT with Retrospective Electrocardiographic Gating
Radiology, November 1, 2004; 233(2): 586 - 589.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Lu, N. Zhuang, S.-S. Mao, J. Child, S. Carson, and M. J. Budoff
Baseline Heart Rate-adjusted Electrocardiographic Triggering for Coronary Artery Electron-Beam CT Angiography
Radiology, November 1, 2004; 233(2): 590 - 595.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Hong, T. K. Pilgram, F. Zhu, and K. T. Bae
Coronary Artery Calcification: Effect of Size of Field of View on Multi-Detector Row CT Measurements
Radiology, October 1, 2004; 233(1): 281 - 285.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
U. J. Schoepf, C. R. Becker, B. M. Ohnesorge, and E. K. Yucel
CT of Coronary Artery Disease
Radiology, July 1, 2004; 232(1): 18 - 37.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Horiguchi, H. Yamamoto, Y. Akiyama, K. Marukawa, N. Hirai, and K. Ito
Coronary Artery Calcium Scoring Using 16-MDCT and a Retrospective ECG-Gating Reconstruction Algorithm
Am. J. Roentgenol., July 1, 2004; 183(1): 103 - 108.
[Abstract] [Full Text] [PDF]


Home page
J CARDIOVASC PHARMACOL THERHome page
M. J. Budoff
Tracking Progression of Heart Disease with Cardiac Computed Tomography
Journal of Cardiovascular Pharmacology and Therapeutics, April 1, 2004; 9(2): 75 - 82.
[Abstract] [PDF]


Home page
RadiologyHome page
W. Stanford, B. H. Thompson, T. L. Burns, S. D. Heery, and M. C. Burr
Coronary Artery Calcium Quantification at Multi-Detector Row Helical CT versus Electron-Beam CT
Radiology, February 1, 2004; 230(2): 397 - 402.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. A. Rumberger and L. Kaufman
A Rosetta Stone for Coronary Calcium Risk Stratification: Agatston, Volume, and Mass Scores in 11,490 Individuals
Am. J. Roentgenol., September 1, 2003; 181(3): 743 - 748.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Hong, K. T. Bae, T. K. Pilgram, and F. Zhu
Coronary Artery Calcium Quantification at Multi-Detector Row CT: Influence of Heart Rate and Measurement Methods on Interacquisition Variability—Initial Experience
Radiology, July 1, 2003; 228(1): 95 - 100.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Lu, N. Zhuang, S.-S. Mao, J. Child, S. Carson, H. Bakhsheshi, and M. J. Budoff
EKG-triggered CT Data Acquisition to Reduce Variability in Coronary Arterial Calcium Score
Radiology, September 1, 2002; 224(3): 838 - 844.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2001 by the Radiological Society of North America.