Breast Imaging |
1 From the Department of Radiology, University of California School of Medicine, San Francisco, CA. Received March 7, 2001; revision requested April 19; revision received May 25; accepted June 7. Address correspondence to E.S.B., Department of Radiology, University of Wisconsin Medical School, E3/311 Clinical Science Center, 600 Highland Avenue, Madison, WI 53792-3252 (e-mail: bburnside@mail.radiology.wisc.edu).
A 51-year-old woman underwent stereotactic core biopsy of suspicious microcalcifications in the upper outer left breast with subsequent metallic clip deployment. Postprocedure mammograms demonstrated accurate placement of the clip. However, mammography 10 months later revealed movement of the clip 4 cm medially in the breast.
Index terms: Breast, biopsy, 00.1261 Breast neoplasms, localization, 00.125
This article has been cited by other articles:
![]() |
K. Calhoun, A. Giuliano, and R. J. Brenner Intraoperative Loss of Core Biopsy Clips: Clinical Implications Am. J. Roentgenol., March 1, 2008; 190(3): W196 - W200. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Parikh Delayed Migration of Gel Mark Ultra Clip Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy Am. J. Roentgenol., July 1, 2005; 185(1): 203 - 206. [Full Text] [PDF] |
||||
![]() |
J. Parikh Clip Migration Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy Am. J. Roentgenol., March 1, 2005; 184(3_supp): S43 - S46. [Full Text] [PDF] |
||||
![]() |
D. M. Lanners, K. K. Amrami, R. S. Jonsgaard, J. J. Gisvold, and J. P. Felmlee Safety and MRI Artifact Evaluation at 1.5 T of Metallic Mounting Sheath of a Marking Clip Inadvertently Deployed at Stereotactic Biopsy Am. J. Roentgenol., September 1, 2004; 183(3): 825 - 829. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Esserman, M. A. Cura, and D. DaCosta Recognizing Pitfalls in Early and Late Migration of Clip Markers after Imaging-guided Directional Vacuum-assisted Biopsy RadioGraphics, January 1, 2004; 24(1): 147 - 156. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Margolin, L. Kaufman, S. R. Denny, R. P. Jacobs, and J. D. Schrumpf Metallic Marker Placement After Stereotactic Core Biopsy of Breast Calcifications: Comparison of Two Clips and Deployment Techniques Am. J. Roentgenol., December 1, 2003; 181(6): 1685 - 1690. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Birdwell and R. J. Jackman Clip or Marker Migration 5-10 Weeks after Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Report of Two Cases Radiology, November 1, 2003; 229(2): 541 - 544. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. T. Harris Clip Migration within 8 Days of 11-gauge Vacuum-assisted Stereotactic Breast Biopsy: Case Report Radiology, August 1, 2003; 228(2): 552 - 554. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |