Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print October 1, 2001, 10.1148/radiol.2212010565
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2212010565v1
221/2/504    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burnside, E. S.
Right arrow Articles by Sickles, E. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burnside, E. S.
Right arrow Articles by Sickles, E. A.
(Radiology. 2001;221:504-507.)
© RSNA, 2001


Breast Imaging

Movement of a Biopsy-Site Marker Clip after Completion of Stereotactic Directional Vacuum-assisted Breast Biopsy: Case Report1

Elizabeth S. Burnside, MD, MPH, Rita E. Sohlich, MD and Edward A. Sickles, MD

1 From the Department of Radiology, University of California School of Medicine, San Francisco, CA. Received March 7, 2001; revision requested April 19; revision received May 25; accepted June 7. Address correspondence to E.S.B., Department of Radiology, University of Wisconsin Medical School, E3/311 Clinical Science Center, 600 Highland Avenue, Madison, WI 53792-3252 (e-mail: bburnside@mail.radiology.wisc.edu).

A 51-year-old woman underwent stereotactic core biopsy of suspicious microcalcifications in the upper outer left breast with subsequent metallic clip deployment. Postprocedure mammograms demonstrated accurate placement of the clip. However, mammography 10 months later revealed movement of the clip 4 cm medially in the breast.

Index terms: Breast, biopsy, 00.1261 • Breast neoplasms, localization, 00.125




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. Calhoun, A. Giuliano, and R. J. Brenner
Intraoperative Loss of Core Biopsy Clips: Clinical Implications
Am. J. Roentgenol., March 1, 2008; 190(3): W196 - W200.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. R. Parikh
Delayed Migration of Gel Mark Ultra Clip Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy
Am. J. Roentgenol., July 1, 2005; 185(1): 203 - 206.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Parikh
Clip Migration Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy
Am. J. Roentgenol., March 1, 2005; 184(3_supp): S43 - S46.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. M. Lanners, K. K. Amrami, R. S. Jonsgaard, J. J. Gisvold, and J. P. Felmlee
Safety and MRI Artifact Evaluation at 1.5 T of Metallic Mounting Sheath of a Marking Clip Inadvertently Deployed at Stereotactic Biopsy
Am. J. Roentgenol., September 1, 2004; 183(3): 825 - 829.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
L. E. Esserman, M. A. Cura, and D. DaCosta
Recognizing Pitfalls in Early and Late Migration of Clip Markers after Imaging-guided Directional Vacuum-assisted Biopsy
RadioGraphics, January 1, 2004; 24(1): 147 - 156.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. R. Margolin, L. Kaufman, S. R. Denny, R. P. Jacobs, and J. D. Schrumpf
Metallic Marker Placement After Stereotactic Core Biopsy of Breast Calcifications: Comparison of Two Clips and Deployment Techniques
Am. J. Roentgenol., December 1, 2003; 181(6): 1685 - 1690.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. L. Birdwell and R. J. Jackman
Clip or Marker Migration 5-10 Weeks after Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Report of Two Cases
Radiology, November 1, 2003; 229(2): 541 - 544.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. T. Harris
Clip Migration within 8 Days of 11-gauge Vacuum-assisted Stereotactic Breast Biopsy: Case Report
Radiology, August 1, 2003; 228(2): 552 - 554.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2001 by the Radiological Society of North America.