Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print January 18, 2002, 10.1148/radiol.2223011263
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2223011263v1
222/3/794    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Philpotts, L. E.
Right arrow Articles by Lee, C. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Philpotts, L. E.
Right arrow Articles by Lee, C. H.
(Radiology 2002;222:794-796.)
© RSNA, 2002


Breast Imaging

Clip Migration after 11-gauge Vacuum-assisted Stereotactic Biopsy: Case Report1

Liane E. Philpotts, MD and Carol H. Lee, MD

1 From the Department of Radiology, Yale University School of Medicine, 333 Cedar St, PO Box 208042, New Haven, CT 06520. Received July 23, 2001; revision requested August 23; revision received September 14; accepted September 20. Address correspondence to L.E.P. (e-mail: philpotts@biomed.med.yale.edu).

A 68-year-old woman underwent stereotactic biopsy of a small cluster of calcifications. The postbiopsy mammograms showed the biopsy-marking clip to be located correctly at the biopsy site. Follow-up mammograms 1 year later showed that the clip migrated to another quadrant of the breast. Findings in this case demonstrate that at long-term follow-up a biopsy-marking clip may not be accurately marking the biopsy site.

© RSNA, 2002

Index terms: Breast, biopsy, 00.1267 • Breast radiography, 00.11 • Foreign bodies, 00.93




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. Calhoun, A. Giuliano, and R. J. Brenner
Intraoperative Loss of Core Biopsy Clips: Clinical Implications
Am. J. Roentgenol., March 1, 2008; 190(3): W196 - W200.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. C. Genson, C. E. Blane, M. A. Helvie, S. A. Waits, and T. L. Chenevert
Effects on Breast MRI of Artifacts Caused by Metallic Tissue Marker Clips
Am. J. Roentgenol., February 1, 2007; 188(2): 372 - 376.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. R. Parikh
Delayed Migration of Gel Mark Ultra Clip Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy
Am. J. Roentgenol., July 1, 2005; 185(1): 203 - 206.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Parikh
Clip Migration Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy
Am. J. Roentgenol., March 1, 2005; 184(3_supp): S43 - S46.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. M. Lanners, K. K. Amrami, R. S. Jonsgaard, J. J. Gisvold, and J. P. Felmlee
Safety and MRI Artifact Evaluation at 1.5 T of Metallic Mounting Sheath of a Marking Clip Inadvertently Deployed at Stereotactic Biopsy
Am. J. Roentgenol., September 1, 2004; 183(3): 825 - 829.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
L. E. Esserman, M. A. Cura, and D. DaCosta
Recognizing Pitfalls in Early and Late Migration of Clip Markers after Imaging-guided Directional Vacuum-assisted Biopsy
RadioGraphics, January 1, 2004; 24(1): 147 - 156.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. L. Birdwell and R. J. Jackman
Clip or Marker Migration 5-10 Weeks after Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Report of Two Cases
Radiology, November 1, 2003; 229(2): 541 - 544.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. T. Harris
Clip Migration within 8 Days of 11-gauge Vacuum-assisted Stereotactic Breast Biopsy: Case Report
Radiology, August 1, 2003; 228(2): 552 - 554.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. L. Smathers
Marking the Cavity Site After Stereotactic Core Needle Breast Biopsy
Am. J. Roentgenol., February 1, 2003; 180(2): 355 - 356.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE