Breast Imaging |
1 From the Department of Radiology, Yale University School of Medicine, 333 Cedar St, PO Box 208042, New Haven, CT 06520. Received July 23, 2001; revision requested August 23; revision received September 14; accepted September 20. Address correspondence to L.E.P. (e-mail: philpotts@biomed.med.yale.edu).
A 68-year-old woman underwent stereotactic biopsy of a small cluster of calcifications. The postbiopsy mammograms showed the biopsy-marking clip to be located correctly at the biopsy site. Follow-up mammograms 1 year later showed that the clip migrated to another quadrant of the breast. Findings in this case demonstrate that at long-term follow-up a biopsy-marking clip may not be accurately marking the biopsy site.
© RSNA, 2002
Index terms: Breast, biopsy, 00.1267 Breast radiography, 00.11 Foreign bodies, 00.93
This article has been cited by other articles:
![]() |
K. Calhoun, A. Giuliano, and R. J. Brenner Intraoperative Loss of Core Biopsy Clips: Clinical Implications Am. J. Roentgenol., March 1, 2008; 190(3): W196 - W200. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. C. Genson, C. E. Blane, M. A. Helvie, S. A. Waits, and T. L. Chenevert Effects on Breast MRI of Artifacts Caused by Metallic Tissue Marker Clips Am. J. Roentgenol., February 1, 2007; 188(2): 372 - 376. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Parikh Delayed Migration of Gel Mark Ultra Clip Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy Am. J. Roentgenol., July 1, 2005; 185(1): 203 - 206. [Full Text] [PDF] |
||||
![]() |
J. Parikh Clip Migration Within 15 Days of 11-Gauge Vacuum-Assisted Stereotactic Breast Biopsy Am. J. Roentgenol., March 1, 2005; 184(3_supp): S43 - S46. [Full Text] [PDF] |
||||
![]() |
D. M. Lanners, K. K. Amrami, R. S. Jonsgaard, J. J. Gisvold, and J. P. Felmlee Safety and MRI Artifact Evaluation at 1.5 T of Metallic Mounting Sheath of a Marking Clip Inadvertently Deployed at Stereotactic Biopsy Am. J. Roentgenol., September 1, 2004; 183(3): 825 - 829. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Esserman, M. A. Cura, and D. DaCosta Recognizing Pitfalls in Early and Late Migration of Clip Markers after Imaging-guided Directional Vacuum-assisted Biopsy RadioGraphics, January 1, 2004; 24(1): 147 - 156. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Birdwell and R. J. Jackman Clip or Marker Migration 5-10 Weeks after Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Report of Two Cases Radiology, November 1, 2003; 229(2): 541 - 544. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. T. Harris Clip Migration within 8 Days of 11-gauge Vacuum-assisted Stereotactic Breast Biopsy: Case Report Radiology, August 1, 2003; 228(2): 552 - 554. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Smathers Marking the Cavity Site After Stereotactic Core Needle Breast Biopsy Am. J. Roentgenol., February 1, 2003; 180(2): 355 - 356. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |