Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2231011125
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baker, J. A.
Right arrow Articles by Soo, M. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baker, J. A.
Right arrow Articles by Soo, M. S.
(Radiology 2002;223:229-238.)
© RSNA, 2002


Breast Imaging

Breast US: Assessment of Technical Quality and Image Interpretation1

Jay A. Baker, MD and Mary Scott Soo, MD

1 From the Division of Breast Imaging, Duke University Medical Center, Erwin Rd, Box 3808, Durham, NC 27710. Received June 28, 2001; revision requested July 23; revision received October 2; accepted October 10. Address correspondence to J.A.B. (e-mail: baker013@mc.duke.edu).

PURPOSE: To determine whether ultrasonography (US) of the breast performed at a wide range of clinical practices conforms to the American College of Radiology (ACR) standards for quality and to assess the interpretations of breast sonograms.

MATERIALS AND METHODS: Static images from 152 breast US examinations performed at 86 institutions were evaluated for compliance with ACR guidelines for breast US hardware, technical factors, imaging protocol, and image annotation. Official interpretations submitted by the referring facilities were compared with static images submitted by the facility. Discrepancies were confirmed by two dedicated breast radiologists after repeat imaging, short-interval follow-up imaging, or biopsy.

RESULTS: A total of 60.5% of cases did not comply with at least one ACR guideline on breast US and included 9.2% of cases with inadequate equipment, 14.7% of cases with inappropriate focal zone placement, at least 14% of cases with static images in only one imaging plane, and 25% of cases with incomplete patient identifiers. Clinically relevant interpretation errors and interpretation discrepancies were confirmed in 23 (15.1%) of 152 cases.

CONCLUSION: The majority of breast US examinations did not comply with at least some of the standards for quality set forth by the ACR. Attention to these basic standards could substantially improve image quality.

© RSNA, 2002

Index terms: Breast, ACR reporting and data system • Breast, US, 00.1298, 00.92, 00.94 • Images, interpretation, 00.1298 • Quality assurance, 00.1298




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
E.-K. Kim, K. H. Ko, K. K. Oh, J. Y. Kwak, J. K. You, M. J. Kim, and B.-W. Park
Clinical Application of the BI-RADS Final Assessment to Breast Sonography in Conjunction with Mammography
Am. J. Roentgenol., May 1, 2008; 190(5): 1209 - 1215.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. J. Kim, E.-K. Kim, J. Y. Kwak, B.-W. Park, S.-I. Kim, J. Sohn, and K. K. Oh
Role of Sonography in the Detection of Contralateral Metachronous Breast Cancer in an Asian Population
Am. J. Roentgenol., February 1, 2008; 190(2): 476 - 480.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
B. Mesurolle, T. Helou, M. El-Khoury, M. Edwardes, E. J. Sutton, and E. Kao
Tissue Harmonic Imaging, Frequency Compound Imaging, and Conventional Imaging: Use and Benefit in Breast Sonography
J. Ultrasound Med., August 1, 2007; 26(8): 1041 - 1051.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
T. G. ODLE
Breast Ultrasound
Radiol. Technol., January 1, 2007; 78(3): 222M - 242M.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. A. Berg, J. D. Blume, J. B. Cormack, and E. B. Mendelson
Operator Dependence of Physician-performed Whole-Breast US: Lesion Detection and Characterization.
Radiology, November 1, 2006; 241(2): 355 - 365.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
M. Costantini, P. Belli, R. Lombardi, G. Franceschini, A. Mule, and L. Bonomo
Characterization of solid breast masses: use of the sonographic breast imaging reporting and data system lexicon.
J. Ultrasound Med., May 1, 2006; 25(5): 649 - 659.
[Abstract] [Full Text] [PDF]