Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print February 21, 2002, 10.1148/radiol.2231010235
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2231010235v1
223/1/263    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, S.
Right arrow Articles by Finn, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, S.
Right arrow Articles by Finn, J. P.
(Radiology 2002;223:263-269.)
© RSNA, 2002


Technical Developments

MR Imaging of the Heart with Cine True Fast Imaging with Steady-State Precession: Influence of Spatial and Temporal Resolutions on Left Ventricular Functional Parameters1

Stephan Miller, MD, Orlando P. Simonetti, PhD, James Carr, MD, Ulrich Kramer, MD and J. Paul Finn, MD

1 From the Department of Diagnostic Radiology, Eberhard-Karls-University, Tübingen, Hoppe-Seyler-Strasse 3, 72076 Tübingen, Germany (S.M., U.K.); Department of MR Research and Development, Siemens Medical Systems, Chicago, Ill (O.P.S.); and Department of MR Research, Northwestern University, Chicago, Ill (J.C., J.P.F.). Received January 4, 2001; revision requested February 26; final revision received August 10; accepted October 10. Address correspondence to S.M. (e-mail: stephan.miller@uni-tuebingen.de).

The influence of changes in spatial and temporal resolutions on functional parameters in the left ventricle (LV) were investigated with magnetic resonance (MR) imaging with a modified true fast imaging with steady-state precession, or FISP, two-dimensional sequence that provided temporal resolution of 21–90 msec and spatial resolution of 1–3 mm. MR imaging in the heart was performed in 15 healthy volunteers. A decrease in LV functional parameters was observed with reduced spatial and temporal resolutions. The influence of temporal resolution was more relevant.

© RSNA, 2002

Index terms: Heart, MR, 51.121412 • Magnetic resonance (MR), cine study • Magnetic resonance (MR), image processing • Magnetic resonance (MR), technology, 51.121412




This article has been cited by other articles:


Home page
RadioGraphicsHome page
F. Saremi, J. D. Grizzard, and R. J. Kim
Optimizing Cardiac MR Imaging: Practical Remedies for Artifacts
RadioGraphics, July 1, 2008; 28(4): 1161 - 1187.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Plumhans, G. Muhlenbruch, A. Rapaee, K.-H. Sim, T. Seyfarth, R. W. Gunther, and A. H. Mahnken
Assessment of Global Right Ventricular Function on 64-MDCT Compared with MRI
Am. J. Roentgenol., May 1, 2008; 190(5): 1358 - 1361.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. U. Juergens, H. Seifarth, F. Range, S. Wienbeck, M. Wenker, W. Heindel, and R. Fischbach
Automated Threshold-Based 3D Segmentation Versus Short-Axis Planimetry for Assessment of Global Left Ventricular Function with Dual-Source MDCT
Am. J. Roentgenol., February 1, 2008; 190(2): 308 - 314.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Brodoefel, U. Kramer, A. Reimann, C. Burgstahler, S. Schroeder, A. Kopp, and M. Heuschmid
Dual-Source CT with Improved Temporal Resolution in Assessment of Left Ventricular Function: A Pilot Study
Am. J. Roentgenol., November 1, 2007; 189(5): 1064 - 1070.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. Marui, K. Tambara, E. Tadamura, Y. Saji, N. Sasahashi, T. Ikeda, T. Nishina, and M. Komeda
A novel approach to restore atrial function after the maze procedure in patients with an enlarged left atrium
Eur. J. Cardiothorac. Surg., August 1, 2007; 32(2): 308 - 312.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Sen-Chowdhry, S. K. Prasad, P. Syrris, R. Wage, D. Ward, R. Merrifield, G. C. Smith, D. N. Firmin, D. J. Pennell, and W. J. McKenna
Cardiovascular Magnetic Resonance in Arrhythmogenic Right Ventricular Cardiomyopathy Revisited: Comparison With Task Force Criteria and Genotype
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2132 - 2140.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Dewey, M. Muller, S. Eddicks, D. Schnapauff, F. Teige, W. Rutsch, A. C. Borges, and B. Hamm
Evaluation of Global and Regional Left Ventricular Function With 16-Slice Computed Tomography, Biplane Cineventriculography, and Two-Dimensional Transthoracic Echocardiography: Comparison With Magnetic Resonance Imaging
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2034 - 2044.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Finn, R. Saleh, S. Thesen, S. G. Ruehm, M. H. Lee, J. Grinstead, J. S. Child, and G. Laub
MR Imaging with Remote Control: Feasibility Study in Cardiovascular Disease
Radiology, November 1, 2006; 241(2): 528 - 537.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. T. Boll, A. S. Bossert, A. J. Aschoff, M. H. Hoffmann, and R. C. Gilkeson
Synergy of MDCT and Cine MRI for the Evaluation of Cardiac Motility
Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S379 - S386.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Lembcke, A. C. Borges, S. Dushe, P. M. Dohmen, T. H. Wiese, P. Rogalla, K.-G. A. Hermann, B. Hamm, and C. N. H. Enzweiler
Assessment of Mitral Valve Regurgitation at Electron-Beam CT: Comparison with Doppler Echocardiography
Radiology, July 1, 2005; 236(1): 47 - 55.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. H. Mahnken, M. Katoh, P. Bruners, E. Spuentrup, J. E. Wildberger, R. W. Gunther, and A. Buecker
Acute Myocardial Infarction: Assessment of Left Ventricular Function with 16-Detector Row Spiral CT versus MR Imaging--Study in Pigs
Radiology, July 1, 2005; 236(1): 112 - 117.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Yamamuro, E. Tadamura, S. Kubo, H. Toyoda, T. Nishina, M. Ohba, R. Hosokawa, T. Kimura, N. Tamaki, M. Komeda, et al.
Cardiac Functional Analysis with Multi-Detector Row CT and Segmental Reconstruction Algorithm: Comparison with Echocardiography, SPECT, and MR Imaging
Radiology, February 1, 2005; 234(2): 381 - 390.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K.-F. J. Kreitner, S. Ley, H.-U. Kauczor, E. Mayer, T. Kramm, M. B. Pitton, F. Krummenauer, and M. Thelen
Chronic Thromboembolic Pulmonary Hypertension: Pre- and Postoperative Assessment with Breath-hold MR Imaging Techniques
Radiology, August 1, 2004; 232(2): 535 - 543.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. Li, P. Storey, Q. Chen, B. S. Y. Li, P. V. Prasad, and R. R. Edelman
Dark Flow Artifacts with Steady-State Free Precession Cine MR Technique: Causes and Implications for Cardiac MR Imaging
Radiology, February 1, 2004; 230(2): 569 - 575.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. U. Juergens, M. Grude, D. Maintz, E. M. Fallenberg, T. Wichter, W. Heindel, and R. Fischbach
Multi-Detector Row CT of Left Ventricular Function with Dedicated Analysis Software versus MR Imaging: Initial Experience
Radiology, February 1, 2004; 230(2): 403 - 410.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2002 by the Radiological Society of North America.