Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2232010221
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nyman, U.
Right arrow Articles by Almén, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nyman, U.
Right arrow Articles by Almén, T.
Related Collections
Right arrowRelated Articles
(Radiology 2002;223:311-318.)
© RSNA, 2002


Viewpoint

Are Gadolinium-based Contrast Media Really Safer than Iodinated Media for Digital Subtraction Angiography in Patients with Azotemia?1

Ulf Nyman, MD, PhD, Barbara Elmståhl, MD, Peter Leander, MD, PhD, Mats Nilsson, PhD, Klaes Golman, PhD and Torsten Almén, MD, PhD

1 From the Departments of Radiology (U.N., B.E., P.L., T.A.) and Radiation Physics (M.N.), University of Lund, Malmö University Hospital, Sweden, and Nycomed Innovation, Medeon, Malmö, Sweden (K.G.). Received December 28, 2000; revision requested March 2, 2001; revision received June 18; accepted July 12. Address correspondence to U.N., Röntgenavdelningen, Lasarettet, SE-231 85 Trelleborg, Sweden (e-mail: ulf.nyman@skane.se).

Gadolinium chelates, intended as intravenous contrast media for magnetic resonance imaging, have been regarded as nonnephrotoxic and recommended to replace iodinated contrast media in patients with azotemia who are undergoing digital subtraction angiography (DSA). High intraarterial doses (up to 220 mmol of gadodiamide) have been used, with a 40% incidence of nephropathy. The authors discourage the use of gadolinium for DSA for several reasons. (a) There exist no randomized studies comparing the nephrotoxic effects of gadolinium-based and iodinated media at equal-attenuating concentrations and doses. (b) Gadolinium-based media are hypertonic, a pathogenetic factor in contrast medium–induced nephropathy after renal angiography, with an osmolality two to seven times that of plasma. Iodinated media in concentrations that are equally attenuating with gadolinium-based media can be made isotonic. (c) In vitro measurements indicate that 0.5 mol/L gadolinium chelates are equally attenuating with 60–80 mg iodine per milliliter at the commonly used 70–90-kV range used for DSA. Thus, 50 mL of 0.5 mol/L gadolinium chelate ({approx}0.3 mmol/kg in an 80-kg person) would be equally attenuating with a dose of 3–4 g of iodine in an iodinated medium (eg, 50 mL iohexol at 60–80 mg I/mL or 10–13 mL at 300 mg I/mL). (d) By combining these data on attenuation and results of toxicity studies in mice, the general toxicity of gadolinium chelates may be six to 25 times higher than that of equal-attenuating doses of iodinated media at 70-kV DSA. Thus, the authors believe that at equal-attenuating doses for DSA, modern iodinated contrast media should result in a lower toxic load on the body than with presently available gadolinium chelates.

© RSNA, 2002

Index terms: Angiography, contrast media, 9*.12112 • Contrast media, complications • Contrast media, effects • Contrast media, toxicity • Iodine and iodine compounds • Gadolinium • Uremia


Related Articles

Gadolinium Chelates in Angiography and Interventional Radiology: A Useful Alternative to Iodinated Contrast Media for Angiography
David J. Spinosa, John A. Kaufmann, and Gary D. Hartwell
Radiology 2002 223: 319-325. [Abstract] [Full Text] [PDF]

Commentary on the Viewpoint of Spinosa et al
Ulf Nyman, Barbara Elmståhl, Peter Leander, Mats Nilsson, Klaes Golman, and Torsten Almén
Radiology 2002 223: 326-327. [Full Text] [PDF]

Commentary on the Viewpoint of Nyman et al
David J. Spinosa, John A. Kaufmann, and Gary D. Hartwell
Radiology 2002 223: 328-329. [Full Text] [PDF]



This article has been cited by other articles:


Home page
RadiologyHome page
J. C. Weinreb
Which Study When? Is Gadolinium-enhanced MR Imaging Safer than Iodine-enhanced CT?
Radiology, October 1, 2008; 249(1): 3 - 8.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
L. E. M. Duijm, E. H. Overbosch, Y. S. Liem, R. N. Planken, J. H. M. Tordoir, P. W. M. Cuypers, P. Douwes-Draaijer, and M. W. de Haan
Retrograde catheterization of haemodialysis fistulae and grafts: angiographic depiction of the entire vascular access tree and stenosis treatment
Nephrol. Dial. Transplant., September 18, 2008; (2008) gfn526v1.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Elmstahl, U. Nyman, P. Leander, K. Golman, C.-M. Chai, D. Grant, R. Doughty, R. Pehrson, J. Bjork, and T. Almen
Iodixanol 320 Results in Better Renal Tolerance and Radiodensity than Do Gadolinium-based Contrast Media: Arteriography in Ischemic Porcine Kidneys
Radiology, April 1, 2008; 247(1): 88 - 97.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
U. Nyman, B. Elmstahl, and P. Leander
Suggesting Gadolinium-based Contrast Media for CT in Azotemic Patients Is Not Based on Historical, Clinical, and Experimental Data
Radiology, August 1, 2007; 244(2): 622 - 623.
[Full Text] [PDF]


Home page
RadiologyHome page
M. Kalinowski, K. Goldmann, M. Gotthardt, M. Rossler, A. Pfestroff, K. J. Klose, and H.-J. Wagner
Effectiveness and Renal Tolerance of Multidetector Helical CT with Gadobutrol: Results of a Comparative Porcine Study
Radiology, August 1, 2007; 244(2): 457 - 463.
[Abstract] [Full Text] [PDF]


Home page
CJASNHome page
A. Deo, M. Fogel, and S. E. Cowper
Nephrogenic Systemic Fibrosis: A Population Study Examining the Relationship of Disease Development to Gadolinium Exposure
Clin. J. Am. Soc. Nephrol., March 1, 2007; 2(2): 264 - 267.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. C. Heinrich, M. K. Kuhlmann, S. Kohlbacher, M. Scheer, A. Grgic, M. B. Heckmann, and M. Uder
Cytotoxicity of Iodinated and Gadolinium-based Contrast Agents in Renal Tubular Cells at Angiographic Concentrations: In Vitro Study
Radiology, December 19, 2006; (2006) 2422060245.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
S. N. Gandhi, M. A. Brown, J. G. Wong, D. A. Aguirre, and C. B. Sirlin
MR Contrast Agents for Liver Imaging: What, When, How
RadioGraphics, November 1, 2006; 26(6): 1621 - 1636.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Becker, H. Thompson, M. Remy-Jardin, J. Remy, and P. Dequiedt
Renal Safety of Gadolinium-based Contrast Agent for Ionizing Radiation Imaging.
Radiology, July 1, 2006; 240(1): 301 - 302.
[Full Text] [PDF]


Home page
RadiologyHome page
S. K. Morcos and M. Remy-Jardin
Gadolinium-based Contrast Media for Multi-Detector Row Spiral CT Pulmonary Angiography in Patients with Renal Insufficiency
Radiology, March 1, 2006; 238(3): 1077 - 1078.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. Zorger, M. Volk, O. W. Hamer, M. Lenhart, J. Seitz, B. Butz, and C. Paetzel
Intraarterial Gadolinium-Enhanced MR Angiography in Humans for the Detection of Infrainguinal Arterial Stenoses Before and After Percutaneous Angioplasty
Am. J. Roentgenol., October 1, 2005; 185(4): 867 - 872.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Saini
Multi-Detector Row CT: Principles and Practice for Abdominal Applications
Radiology, November 1, 2004; 233(2): 323 - 327.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
C. M. Erley, B. D. Bader, E. D. Berger, N. Tuncel, S. Winkler, G. Tepe, T. Risler, and S. Duda
Gadolinium-based contrast media compared with iodinated media for digital subtraction angiography in azotaemic patients
Nephrol. Dial. Transplant., October 1, 2004; 19(10): 2526 - 2531.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. W. Henson, R. G. Nogueira, D. J. Covarrubias, R. G. Gonzalez, and M. H. Lev
Gadolinium-Enhanced CT Angiography of the Circle of Willis and Neck
AJNR Am. J. Neuroradiol., June 1, 2004; 25(6): 969 - 972.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. Nicolini, M. Ferraresso, A. Lovaria, P. Biondetti, M. Raiteri, and L. Berardinelli
Carbon dioxide as a valuable contrast agent for identifying iatrogenic arteriovenous fistulas in transplanted kidneys
Nephrol. Dial. Transplant., October 1, 2003; 18(10): 2189 - 2192.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. K. Wacker, R. M. Maes, J. A. Jesberger, S. G. Nour, J. L. Duerk, and J. S. Lewin
MR Imaging-Guided Vascular Procedures Using CO2 as a Contrast Agent
Am. J. Roentgenol., August 1, 2003; 181(2): 485 - 489.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. A. Turmel-Rodrigues, P. Bourquelot, J. Pengloan, M. L. Robbin, M. E. Lockhart, and M. Allon
Hemodialysis Arteriovenous Fistula Maturity: US Evaluation [letter] * Dr Robbin and colleagues respond:
Radiology, June 1, 2003; 227(3): 906 - 907.
[Full Text] [PDF]


Home page
RadiologyHome page
D. J. Spinosa, J. A. Kaufmann, and G. D. Hartwell
Commentary on the Viewpoint of Nyman et al
Radiology, May 1, 2002; 223(2): 328 - 329.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2002 by the Radiological Society of North America.