Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print March 29, 2002, 10.1148/radiol.2232010665
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2232010665v1
223/2/501    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bertschinger, K. M.
Right arrow Articles by Hilfiker, P. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bertschinger, K. M.
Right arrow Articles by Hilfiker, P. R.
(Radiology 2002;223:501-508.)
© RSNA, 2002


Genitourinary Imaging

Dynamic MR Imaging of the Pelvic Floor Performed with Patient Sitting in an Open-Magnet Unit versus with Patient Supine in a Closed-Magnet Unit1

Katharina M. Bertschinger, MD, Frank H. Hetzer, MD, Justus E. Roos, MD, Karl Treiber, RT, Borut Marincek, MD and Paul R. Hilfiker, MD

1 From the Institute of Diagnostic Radiology (K.M.B., J.E.R., K.T., B.M., P.R.H.) and Department of Visceral and Transplant Surgery (F.H.H.), University Hospital Zurich, Rämistrasse 100, CH-8091 Zurich, Switzerland. Received March 26, 2001; revision requested April 25; revision received August 1; accepted September 17. Address correspondence to P.R.H. (e-mail: paul.hilfiker@mri-roentgen.ch).

PURPOSE: To compare open-magnet magnetic resonance (MR) imaging performed with the patient sitting with dynamic closed-magnet MR imaging of the pelvic floor performed with the patient supine.

MATERIALS AND METHODS: Thirty-eight patients underwent dynamic 1.5-T closed-magnet pelvic floor MR imaging while in the supine position. Midsagittal T2-weighted single-shot fast spin-echo and T1-weighted multiphase spoiled gradient-recalled-echo (SPGR) MR images were obtained before and after rectal contrast agent administration, respectively, with the patient at rest, straining, and maximally contracting the sphincter. Subsequently, the patient was transferred to an open 0.5-T system. Midsagittal multiphase T1-weighted SPGR MR images were then obtained every 2 seconds with the patient sitting while at rest, maximally contracting the sphincter, straining, and defecating. Images were analyzed with regard to presence of enteroceles, anterior rectoceles, intussusceptions, rectal descents, bladder descents, and vaginal vault descents.

RESULTS: All intussusceptions were missed at supine MR imaging. With sitting MR imaging as the reference standard, the sensitivity of supine MR imaging was 79% for depiction of bladder descents. When MR findings were graded and clinically irrelevant MR findings were excluded, sensitivity increased to 100% for depiction of bladder descents and anterior rectoceles and to 96% for depiction of rectal descents.

CONCLUSION: Dynamic supine MR imaging performed with a closed-configuration unit before and after rectal contrast agent administration appears to be an alternative to sitting MR defecography performed with an open-configuration unit for diagnosis of clinically relevant pelvic floor abnormalities.

© RSNA, 2002

Index terms: Pelvic organs, MR, 757.121411, 757.121412, 757.121416, 757.12143 • Pelvic organs, prolapse, 757.159, 80.1499 • Rectum, abnormalities, 757.159, 757.73




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
E. M. Hecht, V. S. Lee, T. P. Tanpitukpongse, J. S. Babb, B. Taouli, S. Wong, N. Rosenblum, J. A. Kanofsky, and G. L. Bennett
MRI of Pelvic Floor Dysfunction: Dynamic True Fast Imaging with Steady-State Precession Versus HASTE
Am. J. Roentgenol., August 1, 2008; 191(2): 352 - 358.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
L. Boyadzhyan, S. S. Raman, and S. Raz
Role of Static and Dynamic MR Imaging in Surgical Pelvic Floor Dysfunction
RadioGraphics, July 1, 2008; 28(4): 949 - 967.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. E. Solopova, F. H. Hetzer, B. Marincek, and D. Weishaupt
MR Defecography: Prospective Comparison of Two Rectal Enema Compositions
Am. J. Roentgenol., February 1, 2008; 190(2): W118 - W124.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
E M ANDERSON, C G FERRETT, and I LINDSEY
Imaging of the pelvic floor
Imaging, December 1, 2006; 18(4): 218 - 227.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. E. Roos, D. Weishaupt, S. Wildermuth, J. K. Willmann, B. Marincek, and P. R. Hilfiker
Experience of 4 Years with Open MR Defecography: Pictorial Review of Anorectal Anatomy and Disease
RadioGraphics, July 1, 2002; 22(4): 817 - 832.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2002 by the Radiological Society of North America.