Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print April 25, 2002, 10.1148/radiol.2233011157
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2233011157v1
223/3/689    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maris, T. G.
Right arrow Articles by Gourtsoyiannis, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maris, T. G.
Right arrow Articles by Gourtsoyiannis, N.
(Radiology 2002;223:689-694.)
© RSNA, 2002


Experimental Studies

Transtympanic Iontophoresis with a Biocompatible Paramagnetic Solution at MR Imaging: Experimental Feasibility Study in Rabbits1

Thomas G. Maris, PhD, Panos Prassopoulos, MD, Nikos Papanikolaou, BSc, Panagiotis Christodoulou, MD, Panagiotis G. Doxas, MD, Emmanuel S. Helidonis, MD and Nikos Gourtsoyiannis, MD

1 From the Department of Medical Physics, University Hospital of Heraklion, Crete, Greece (T.G.M.); and the Departments of Radiology (P.P., N.P., N.G.) and Otolaryngology (P.C., P.G.D., E.S.H.), Medical School of Crete, PO Box 1393, 71500 Stavrakia, Heraklion, Crete, Greece. Received July 6, 2001; revision requested August 20; revision received October 24; accepted November 12. Address correspondence to P.P. (e-mail: tmaris@med.uoc.gr).

PURPOSE: To determine the feasibility of transtympanic iontophoresis in experimental animals with a paramagnetic contrast agent at magnetic resonance (MR) imaging.

MATERIALS AND METHODS: Optimal MR sequence parameters and appropriate paramagnetic ion concentrations of a water and gadopentetate dimeglumine solution were initially assessed with phantoms. Iontophoresis was performed in left ears of five rabbits after the external auditory canals were filled with a solution of water and gadopentetate dimeglumine of optimal concentration, and right ears were used as controls. Signal-to-structural noise ratio (SSNR) and contrast-to-structural noise ratio (CSNR) were measured by using regions of interest, and the overall image quality was assessed subjectively.

RESULTS: Spin-echo (SE) MR sequences were superior to gradient-echo (GRE) MR sequences in terms of SSNR, CSNR, and overall image quality. Highest SSNR and CSNR values were achieved with 2 mmol/L (2 mM) of gadopentetate dimeglumine solution with both SE (repetition time msec/echo time msec, 500/12; flip angle, 90°) and GRE (300/10; flip angle, 90°) sequences in both phantoms and animals. The high signal intensity of gadopentetate dimeglumine solution was recognized in middle ears, vestibules, and semicircular canals of all rabbit ears that had undergone iontophoresis and in none of the control ears.

CONCLUSION: With the solution of water and gadopentetate dimeglumine, the maximum SSNR and CSNR with both SE and GRE MR imaging sequences were achieved. The solution can be transferred to the middle and inner ear cavities across an intact tympanic membrane by using transtympanic iontophoresis.

© RSNA, 2002

Index terms: Animals • Ear, inflammation and infection • Ear, MR, 212.121411, 212.121412, 212.12143, 213.121411, 213.121412, 213.12143 • Experimental study







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2002 by the Radiological Society of North America.