Technical Developments |
1 From the Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn, Germany (P.M., S.F., F.T., H.H.S.); and Philips Medical Systems, Best, the Netherlands (J.S.B., J.G.). Received June 27, 2001; revision requested August 16; revision received October 24; accepted December 10. P.M. supported by a BONFOR grant from the Medical Department of the University of Bonn. Address correspondence to P.M. (e-mail: muertz@uni-bonn.de).
Magnetic resonance (MR) diffusion measurements of the abdomen were performed in 12 healthy volunteers by using a diffusion-weighted single-shot sequence both without and with pulse triggering for different trigger delays. Pulse triggering to the diastolic heart phase led to reduced motion artifacts on the diffusion-weighted MR images and to significantly improved accuracy and reproducibility of measurements of the apparent diffusion coefficients, or ADCs, of abdominal organs.
© RSNA, 2002
Index terms: Abdomen, MR, 70.12144, 70.121416 Magnetic resonance (MR), diffusion study, 70.12144 Magnetic resonance (MR), echo planar, 70.121416 Magnetic resonance (MR), technology, 70.121416
This article has been cited by other articles:
![]() |
J. Zhang, Y. Mazaheri Tehrani, L. Wang, N. M. Ishill, L. H. Schwartz, and H. Hricak Renal Masses: Characterization with Diffusion-weighted MR Imaging--A Preliminary Experience Radiology, May 1, 2008; 247(2): 458 - 464. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Nomori, T. Mori, K. Ikeda, K. Kawanaka, S. Shiraishi, K. Katahira, and Y. Yamashita Diffusion-weighted magnetic resonance imaging can be used in place of positron emission tomography for N staging of non-small cell lung cancer with fewer false-positive results. J. Thorac. Cardiovasc. Surg., April 1, 2008; 135(4): 816 - 822. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Inan, A. Arslan, G. Akansel, Y. Anik, H. T. Sarisoy, E. Ciftci, and A. Demirci Diffusion-Weighted Imaging in the Differential Diagnosis of Simple and Hydatid Cysts of the Liver Am. J. Roentgenol., November 1, 2007; 189(5): 1031 - 1036. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Taouli, A. J. Tolia, M. Losada, J. S. Babb, E. S. Chan, M. A. Bannan, and H. Tobias Diffusion-Weighted MRI for Quantification of Liver Fibrosis: Preliminary Experience Am. J. Roentgenol., October 1, 2007; 189(4): 799 - 806. [Abstract] [Full Text] [PDF] |
||||
![]() |
D.-M. Koh and D. J. Collins Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology Am. J. Roentgenol., June 1, 2007; 188(6): 1622 - 1635. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yoshikawa, H. Kawamitsu, D. G. Mitchell, Y. Ohno, Y. Ku, Y. Seo, M. Fujii, and K. Sugimura ADC measurement of abdominal organs and lesions using parallel imaging technique. Am. J. Roentgenol., December 1, 2006; 187(6): 1521 - 1530. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. C. Thoeny, F. De Keyzer, R. H. Oyen, and R. R. Peeters Diffusion-weighted MR Imaging of Kidneys in Healthy Volunteers and Patients with Parenchymal Diseases: Initial Experience Radiology, June 1, 2005; 235(3): 911 - 917. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Taouli, A. J. Martin, A. Qayyum, R. B. Merriman, D. Vigneron, B. M. Yeh, and F. V. Coakley Parallel Imaging and Diffusion Tensor Imaging for Diffusion-Weighted MRI of the Liver: Preliminary Experience in Healthy Volunteers Am. J. Roentgenol., September 1, 2004; 183(3): 677 - 680. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |