Technical Developments |
1 From the University Clinic for Radiology, Department of Angiography and Interventional Radiology (R.A.B., J.L.), and the University Clinic for Internal Medicine II, Department of Angiology (M.R., I.K., R.A., E.M.), Vienna General Hospital, Währinger Gürtel 18-20, A-1090 Vienna, Austria. Received August 16, 2001; revision requested September 13; final revision received March 20, 2002; accepted March 26. Address correspondence to R.A.B. (e-mail: robert.bucek@akh-wien.ac.at).
In this prospective pilot trial, B-flow ultrasonographic (US) imaging was compared with color duplex flow US in the evaluation of internal carotid arterial stenosis. Despite almost excellent interobserver variability, none of the investigated B-flow imaging parameters correlated with those of duplex US. In conclusion, the investigated B-flow imaging parameters cannot be used in evaluating internal carotid arterial stenosis.
© RSNA, 2002
Index terms: Arteriosclerosis, 172.7211 Carotid arteries, angiography, 172.1248, 908.122 Carotid arteries, stenosis or obstruction, 172.721, 908.721 Carotid arteries, US, 172.12983, 172.12984, 172.12989 Ultrasound (US), Doppler studies, 172.12983, 172.12984, 172.12989
This article has been cited by other articles:
![]() |
L. Brunese, A. Romeo, S. Iorio, G. Napolitano, S. Fucili, P. Zeppa, G. Vallone, G. Lombardi, A. Bellastella, B. Biondi, et al. Thyroid B-flow twinkling sign: a new feature of papillary cancer Eur. J. Endocrinol., October 1, 2008; 159(4): 447 - 451. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Magnoni, S. Coli, M. M. Marrocco-Trischitta, G. Melisurgo, D. De Dominicis, D. Cianflone, R. Chiesa, S. B. Feinstein, and A. Maseri Contrast-enhanced ultrasound imaging of periadventitial vasa vasorum in human carotid arteries Eur J Echocardiogr, August 29, 2008; (2008) jen221v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Reiter, R. Horvat, S. Puchner, W. Rinner, P. Polterauer, J. Lammer, E. Minar, and R.A Bucek Plaque Imaging of the Internal Carotid Artery--Correlation of B-Flow Imaging with Histopathology AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 122 - 126. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.O. Oktar, C. Yucel, D. Karaosmanoglu, K. Akkan, H. Ozdemir, N. Tokgoz, and T. Tali Blood-Flow Volume Quantification in Internal Carotid and Vertebral Arteries: Comparison of 3 Different Ultrasound Techniques with Phase-Contrast MR Imaging. AJNR Am. J. Neuroradiol., February 1, 2006; 27(2): 363 - 369. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Yurdakul, M. Tola, and T. Cumhur B-flow Imaging for Assessment of 70% to 99% Internal Carotid Artery Stenosis Based on Residual Lumen Diameter J. Ultrasound Med., February 1, 2006; 25(2): 211 - 215. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tola, M. Yurdakul, and T. Cumhur B-Flow Imaging in Low Cervical Internal Carotid Artery Dissection J. Ultrasound Med., November 1, 2005; 24(11): 1497 - 1502. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Yucel, S. O. Oktar, Y. Erten, A. Bursali, and H. Ozdemir B-Flow Sonographic Evaluation of Hemodialysis Fistulas: A Comparison With Low- and High-Pulse Repetition Frequency Color and Power Doppler Sonography J. Ultrasound Med., November 1, 2005; 24(11): 1503 - 1508. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |