Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2252011512
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Krombach, G. A.
Right arrow Articles by Saeed, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Krombach, G. A.
Right arrow Articles by Saeed, M.
(Radiology 2002;225:479-486.)
© RSNA, 2002


Experimental Studies

MR Imaging of Spatial Extent of Microvascular Injury in Reperfused Ischemically Injured Rat Myocardium: Value of Blood Pool Ultrasmall Superparamagnetic Particles of Iron Oxide1

Gabriele A. Krombach, MD, Michael F. Wendland, PhD, Charles B. Higgins, MD and Maythem Saeed, DVM, PhD

1 From the Department of Radiology, University of California San Francisco, 505 Parnassus Ave, L308, San Francisco, CA 94143-0628. From the 2001 RSNA scientific assembly. Received September 11, 2001; revision requested November 1; final revision received March 6, 2002; accepted March 28. Address correspondence to M.S. (e-mail: maythem.saeed@radiology.ucsf.edu).

PURPOSE: To (a) assess the value of a blood pool magnetic resonance (MR) imaging contrast agent (Clariscan) for characterizing microvascular injury in ischemically injured rat myocardium and (b) compare the extent of microvascular injury at Clariscan-enhanced MR imaging with infarction and areas at risk seen with histochemical staining.

MATERIALS AND METHODS: Twenty rats underwent 45 minutes of coronary artery occlusion and 3 hours of reperfusion. Sequential T1-weighted spin-echo MR images were acquired in 10 rats to assess leakage of Clariscan into myocardium over time. Ten other rats underwent the same duration of occlusion and reperfusion (3 hours) so that the extent of microvascular injury in the entire heart could be measured and correlated with infarction and area at risk at necropsy. The Student t test and Bland-Altman method were used for data analysis.

RESULTS: Clariscan improved visualization of regions with transmural and nontransmural microvascular injury. Accumulation of Clariscan was best reflected by the mean ratios of signal intensity in injured myocardium to that in normal myocardium measured before (0.98 ± 0.01 [standard error of the mean]) and after (1.34 ± 0.04) injection. At 15 minutes after injection, the size of the enhanced region remained constant over the course of observation. The mean size of the hyperenhanced region (44% of the left ventricle ± 2) was significantly (P < .001) larger than the mean size of true infarction at necropsy (29% ± 3) but smaller than the mean size of the area at risk (50% ± 2).

CONCLUSION: Clariscan has potential for estimating the spatial extent of microvascular injury in ischemically injured myocardium and may be useful as a marker of microvascular injury after thrombolytic therapy.

© RSNA, 2002

Index terms: Animals • Iron • Magnetic resonance (MR), contrast media • Magnetic resonance (MR), experimental studies • Myocardium, infarction, 511.814




This article has been cited by other articles:


Home page
CirculationHome page
D. E. Sosnovik, M. Nahrendorf, and R. Weissleder
Molecular Magnetic Resonance Imaging in Cardiovascular Medicine
Circulation, April 17, 2007; 115(15): 2076 - 2086.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Saeed, O. Weber, R. Lee, L. Do, A. Martin, D. Saloner, P. Ursell, P. Robert, C. Corot, and C. B. Higgins
Discrimination of Myocardial Acute and Chronic (Scar) Infarctions on Delayed Contrast Enhanced Magnetic Resonance Imaging With Intravascular Magnetic Resonance Contrast Media
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 1961 - 1968.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
C. Jackowski, A. Christe, M. Sonnenschein, E. Aghayev, and M. J. Thali
Postmortem unenhanced magnetic resonance imaging of myocardial infarction in correlation to histological infarction age characterization
Eur. Heart J., October 2, 2006; 27(20): 2459 - 2467.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. A. Krombach, C. B. Higgins, M. Chujo, and M. Saeed
Gadomer-enhanced MR Imaging in the Detection of Microvascular Obstruction: Alleviation with Nicorandil Therapy
Radiology, August 1, 2005; 236(2): 510 - 518.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. R. Edelman
Contrast-enhanced MR Imaging of the Heart: Overview of the Literature
Radiology, September 1, 2004; 232(3): 653 - 668.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
T. Fujiwara, K. Togashi, T. Yamaoka, A. Nakai, A. Kido, S. Nishio, T. Yamamoto, H. Kitagaki, and S. Fujii
Kinematics of the Uterus: Cine Mode MR Imaging
RadioGraphics, January 1, 2004; 24(1): e19 - e19.
[Abstract] [Full Text]