Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2253011376
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Armato, S. G.
Right arrow Articles by Doi, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Armato, S. G., III
Right arrow Articles by Doi, K.
(Radiology 2002;225:685-692.)
© RSNA, 2002


Thoracic Imaging

Lung Cancer: Performance of Automated Lung Nodule Detection Applied to Cancers Missed in a CT Screening Program1

Samuel G. Armato, III, PhD, Feng Li, MD, Maryellen L. Giger, PhD, Heber MacMahon, MD, Shusuke Sone, MD and Kunio Doi, PhD

1 From the Kurt Rossmann Laboratories for Radiologic Image Research, Department of Radiology, University of Chicago, 5841 S Maryland Ave, MC 2026, Chicago, IL 60637 (S.G.A., F.L., M.L.G., H.M., K.D.); and Department of Radiology, Azumi General Hospital, Nagano, Japan (S.S.). From the 2001 RSNA scientific assembly. Received August 13, 2001; revision requested October 10; revision received March 8, 2002; accepted May 7. Supported in part by United States Public Health Service grants CA83908, CA64370, and CA62525, funding from the University of Chicago Cancer Research Center, and a grant from the Grant Healthcare Foundation through the Medical Imaging and Research Foundation of the University of Chicago. Address correspondence to S.G.A. (e-mail: s-armato@uchicago.edu).

PURPOSE: To evaluate the performance of a fully automated computerized method for the detection of lung nodules in computed tomographic (CT) scans in the identification of lung cancers that may be missed during visual interpretation.

MATERIALS AND METHODS: A database of 38 low-dose CT scans with 50 lung nodules was obtained from a lung cancer screening program. Thirty-eight of the nodules represented biopsy-confirmed lung cancers that had not been reported during initial clinical interpretation. A computer detection method that involved the use of gray-level thresholding techniques to identify three-dimensionally contiguous structures within the lungs was applied to the CT data. Computer-extracted volume was used to determine whether a structure became a nodule candidate. A rule-based scheme and a cascaded automated classifier were applied to the set of nodule candidates to distinguish actual nodules from areas of normal anatomy. Overall performance of the computer detection method was evaluated with free-response receiver operating characteristic (FROC) analysis.

RESULTS: At a specific operating point on the FROC curve, the method achieved a sensitivity of 80% (40 of 50 nodules), with an average of 1.0 false-positive detection per section. Missed cancers were detected by the computerized method with a sensitivity of 84% (32 of 38 nodules) and a false-positive rate of 1.0 per section.

CONCLUSION: With an automated lung nodule detection method, a large fraction (84%, 32 of 38) of missed cancers in a database of low-dose CT scans were detected correctly.

© RSNA, 2002

Index terms: Cancer screening • Computed tomography (CT), image processing • Computers, diagnostic aid • Lung neoplasms, CT, 60.12115, 60.30




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. Beigelman-Aubry, P. Raffy, W. Yang, R. A. Castellino, and P. A. Grenier
Computer-Aided Detection of Solid Lung Nodules on Follow-Up MDCT Screening: Evaluation of Detection, Tracking, and Reading Time
Am. J. Roentgenol., October 1, 2007; 189(4): 948 - 955.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Peloschek, J. Sailer, M. Weber, C. J. Herold, M. Prokop, and C. Schaefer-Prokop
Pulmonary Nodules: Sensitivity of Maximum Intensity Projection versus That of Volume Rendering of 3D Multidetector CT Data
Radiology, May 1, 2007; 243(2): 561 - 569.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. J. Jeong, C. A. Yi, and K. S. Lee
Solitary Pulmonary Nodules: Detection, Characterization, and Guidance for Further Diagnostic Workup and Treatment
Am. J. Roentgenol., January 1, 2007; 188(1): 57 - 68.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Das, G. Muhlenbruch, A. H. Mahnken, T. G. Flohr, L. Gundel, S. Stanzel, T. Kraus, R. W. Gunther, and J. E. Wildberger
Small Pulmonary Nodules: Effect of Two Computer-aided Detection Systems on Radiologist Performance.
Radiology, November 1, 2006; 241(2): 564 - 571.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
C. C. Jaffe
Measures of Response: RECIST, WHO, and New Alternatives
J. Clin. Oncol., July 10, 2006; 24(20): 3245 - 3251.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Yuan, P. M. Vos, and P. L. Cooperberg
Computer-Aided Detection in Screening CT for Pulmonary Nodules.
Am. J. Roentgenol., May 1, 2006; 186(5): 1280 - 1287.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Awai, K. Murao, A. Ozawa, Y. Nakayama, T. Nakaura, D. Liu, K. Kawanaka, Y. Funama, S. Morishita, and Y. Yamashita
Pulmonary Nodules: Estimation of Malignancy at Thin-Section Helical CT--Effect of Computer-aided Diagnosis on Performance of Radiologists
Radiology, April 1, 2006; 239(1): 276 - 284.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Gur
Lung Cancer Screening: Radiology's Opportunity Here and Now
Radiology, February 1, 2006; 238(2): 395 - 397.
[Full Text] [PDF]


Home page
RadiologyHome page
F. Li, H. Arimura, K. Suzuki, J. Shiraishi, Q. Li, H. Abe, R. Engelmann, S. Sone, H. MacMahon, and K. Doi
Computer-aided Detection of Peripheral Lung Cancers Missed at CT: ROC Analyses without and with Localization
Radiology, November 1, 2005; 237(2): 684 - 690.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. G. Kim, J. M. Goo, J. H. Kim, H. J. Lee, B. G. Min, K. T. Bae, and J.-G. Im
Computer-aided Diagnosis of Localized Ground-Glass Opacity in the Lung at CT: Initial Experience
Radiology, November 1, 2005; 237(2): 657 - 661.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. K. Leader, T. E. Warfel, C. R. Fuhrman, S. K. Golla, J. L. Weissfeld, R. S. Avila, W. D. Turner, and B. Zheng
Pulmonary Nodule Detection with Low-Dose CT of the Lung: Agreement Among Radiologists
Am. J. Roentgenol., October 1, 2005; 185(4): 973 - 978.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K. Peldschus, P. Herzog, S. A. Wood, J. I. Cheema, P. Costello, and U. J. Schoepf
Computer-Aided Diagnosis as a Second Reader: Spectrum of Findings in CT Studies of the Chest Interpreted as Normal
Chest, September 1, 2005; 128(3): 1517 - 1523.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. Goo, T. Tongdee, R. Tongdee, K. Yeo, C. F. Hildebolt, and K. T. Bae
Volumetric Measurement of Synthetic Lung Nodules with Multi-Detector Row CT: Effect of Various Image Reconstruction Parameters and Segmentation Thresholds on Measurement Accuracy
Radiology, June 1, 2005; 235(3): 850 - 856.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K Doi
Current status and future potential of computer-aided diagnosis in medical imaging
Br. J. Radiol., January 1, 2005; 78(suppl_1): S3 - s19.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. D. Rubin, J. K. Lyo, D. S. Paik, A. J. Sherbondy, L. C. Chow, A. N. Leung, R. Mindelzun, P. K. Schraedley-Desmond, S. E. Zinck, D. P. Naidich, et al.
Pulmonary Nodules on Multi-Detector Row CT Scans: Performance Comparison of Radiologists and Computer-aided Detection
Radiology, January 1, 2005; 234(1): 274 - 283.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
E. F. Patz Jr, S. J. Swensen, and J. E. Herndon II
Estimate of Lung Cancer Mortality From Low-Dose Spiral Computed Tomography Screening Trials: Implications for Current Mass Screening Recommendations
J. Clin. Oncol., June 1, 2004; 22(11): 2202 - 2206.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. N. Bryan
The Digital rEvolution: The Millennial Change in Medical Imaging
Radiology, November 1, 2003; 229(2): 299 - 304.
[Full Text] [PDF]


Home page
RadiologyHome page
C. D. Johnson
Hard- versus Soft-Copy Interpretation
Radiology, June 1, 2003; 227(3): 629 - 630.
[Full Text] [PDF]


Home page
RadiologyHome page
F. Li, S. Sone, H. Abe, H. MacMahon, S. G. Armato III, and K. Doi
Lung Cancers Missed at Low-Dose Helical CT Screening in a General Population: Comparison of Clinical, Histopathologic, and Imaging Findings
Radiology, December 1, 2002; 225(3): 673 - 683.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2002 by the Radiological Society of North America.