Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2253011806
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Greenfield, A. L.
Right arrow Articles by Kahn, M. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Greenfield, A. L.
Right arrow Articles by Kahn, M. B.
(Radiology 2002;225:845-851.)
© RSNA, 2002


Ultrasonography

Application of Duplex US for Characterization of Endoleaks in Abdominal Aortic Stent-Grafts: Report of Five Cases1

Antje L. Greenfield, MD, Ethan J. Halpern, MD, Joseph Bonn, MD, Richard J. Wechsler, MD and Mark B. Kahn, MD

1 From the Departments of Radiology (A.L.G., E.J.H., J.B., R.J.W.) and Surgery (M.B.K.), Thomas Jefferson University Hospital, Philadelphia, Pa. Received November 8, 2001; revision requested December 27; revision received April 12, 2002; accepted May 24. Address correspondence to A.L.G., 923 Mill Creek Rd, Gladwyne, PA 19035 (e-mail: antje.greenfield@mail.tju.edu).

Endoleaks were detected with helical computed tomographic (CT) angiography in five patients after placement of an aortobiliac stent-graft. The leaks were subsequently evaluated with duplex ultrasonography (US) and, in four patients, with conventional aortography as well. CT angiography revealed a total of seven endoleaks, all of which were prospectively classified as reconstitution (type II) leaks. Duplex US demonstrated six of the seven endoleaks. At duplex US, two of the leaks were characterized as attachment-site (type I) leaks; these two diagnoses were confirmed during subsequent angiography and profoundly altered clinical care. As an adjunct to CT angiography in evaluating endoleaks, duplex US provides hemodynamic information that enables further characterization of the type of endoleak and facilitates appropriate clinical care.

© RSNA, 2002

Index terms: Aneurysm, aortic, 943.73 • Aorta, grafts and prostheses, 943.1268 • Computed tomography (CT), angiography, 943.12912 • Ultrasound (US), Doppler studies, 943.12984




This article has been cited by other articles:


Home page
RadiologyHome page
S. W. Stavropoulos and S. R. Charagundla
Imaging Techniques for Detection and Management of Endoleaks after Endovascular Aortic Aneurysm Repair
Radiology, June 1, 2007; 243(3): 641 - 655.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. Napoli, I. Bargellini, S. G. Sardella, P. Petruzzi, R. Cioni, C. Vignali, M. Ferrari, and C. Bartolozzi
Abdominal Aortic Aneurysm: Contrast-enhanced US for Missed Endoleaks after Endoluminal Repair
Radiology, October 1, 2004; 233(1): 217 - 225.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2002 by the Radiological Society of North America.