Nuclear Medicine |
1 From the Departments of Surgery, Division of Trauma Surgery (M.S., O.T.) and Medical Radiology, Division of Nuclear Medicine (K.D.M.S., G.K.v.S.), University Hospital, Rämistrasse 100, CH-8091 Zurich, Switzerland; and Department of Surgery, Division of Trauma Surgery, Monash University, Alfred Hospital, Melbourne, Australia (T.K.). From the 2001 RSNA scientific assembly. Received November 27, 2001; revision requested February 11, 2002; final revision received June 18; accepted June 27. Address correspondence to G.K.v.S. (e-mail: vonschulthess@dmr.usz.ch).
PURPOSE: To prospectively evaluate the value of positron emission tomography (PET) with fluorine 18 fluorodeoxyglucose (FDG) in the detection of metallic implantassociated infections in patients with trauma.
MATERIALS AND METHODS: Twenty-nine partial-body FDG PET scans in 22 patients suspected of having metallic implantassociated infections were obtained prior to surgery. In two of the 22 patients, data were acquired with a combined PET-CT in-line system. Soft-tissue and bone infections were evaluated. PET scans were analyzed by two experienced nuclear medicine physicians first separately and then in consensus. Disease status was defined on the basis of the results of microbiologic evaluation of surgical specimens together with intraoperative findings. Sensitivities, specificities, accuracies, interobserver variability (determination of
values), and receiver operating characteristic curves were obtained.
RESULTS: Of 29 PET scans, 14 were true-positive, 14 were true-negative, and one was false-positive. Sensitivity, specificity, and accuracy were 100%, 93.3%, and 97%, respectively, for all PET data; 100%, 100%, and 100%, respectively, for the central skeleton; and 100%, 87.5%, and 95%, respectively, for the peripheral skeleton. The degree of overall interobserver concordance was high (
= 0.96).
CONCLUSION: FDG PET appears to be a sensitive and specific method for the detection of infectious foci due to metallic implants in patients with trauma.
© RSNA, 2003
Index terms: Bones, infection, 30.21, 30.453, 40.21, 40.453 Computed tomography (CT), helical, 30.12115, 40.12115 Dual-modality imaging, PET/CT Metallic devices, 30.453, 40.453 Positron emission tomography (PET), 30.12163, 30.12165, 40.12163, 40.12165
This article has been cited by other articles:
![]() |
G. K. von Schulthess, H. C. Steinert, and T. F. Hany Integrated PET/CT: Current Applications and Future Directions Radiology, February 1, 2006; 238(2): 405 - 422. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.F. Termaat, P.G.H.M. Raijmakers, H.J. Scholten, F.C. Bakker, P. Patka, and H.J.T.M. Haarman The Accuracy of Diagnostic Imaging for the Assessment of Chronic Osteomyelitis: A Systematic Review and Meta-Analysis J. Bone Joint Surg. Am., November 1, 2005; 87(11): 2464 - 2471. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. D. M. Stumpe, H. P. Notzli, M. Zanetti, E. M. Kamel, T. F. Hany, G. W. Gorres, G. K. von Schulthess, and J. Hodler FDG PET for Differentiation of Infection and Aseptic Loosening in Total Hip Replacements: Comparison with Conventional Radiography and Three-Phase Bone Scintigraphy Radiology, May 1, 2004; 231(2): 333 - 341. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Wahl Why Nearly All PET of Abdominal and Pelvic Cancers Will Be Performed as PET/CT J. Nucl. Med., January 1, 2004; 45(90010): 82S - 95. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |