Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2262011593
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hussain, H. K.
Right arrow Articles by Chenevert, T. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hussain, H. K.
Right arrow Articles by Chenevert, T. L.
(Radiology 2003;226:558-566.)
© RSNA, 2003


Technical Developments

Hepatic Arterial Phase MR Imaging with Automated Bolus-Detection Three-dimensional Fast Gradient-Recalled-Echo Sequence: Comparison with Test-Bolus Method1

Hero K. Hussain, MD, Frank J. Londy, RT, Isaac R. Francis, MD, Hanh V. Nghiem, MD, William J. Weadock, MD, Achamyeleh Gebremariam, MSc and Thomas L. Chenevert, PhD

1 From the Department of Radiology, University of Michigan Health System, 1500 E Medical Center Dr, UH B2B311-MRI, Ann Arbor, MI 48109-0030. Received September 27, 2001; revision requested December 10; final revision received May 8, 2002; accepted May 15. Address correspondence to H.K.H. (e-mail: hhussain@umich.edu).

Sixty-two patients underwent magnetic resonance (MR) imaging of the liver with the automated contrast material bolus–detection technique. Arterial phase MR images were assessed quantitatively and qualitatively. In 23 patients, a test bolus of contrast material was injected intravenously before dynamic MR imaging. There was good correlation and agreement between delay times estimated with both timing methods. Eighty-three percent of arterial phase images obtained with automated contrast material bolus detection were optimal. There was good correlation and agreement between delay times estimated with both timing methods. Optimal hepatic arterial phase MR images can be obtained routinely with automated detection of a contrast material bolus.

© RSNA, 2003

Index terms: Liver, cirrhosis, 761.794 • Liver, MR, 761.121411, 761.121412 • Liver neoplasms, MR, 761.121411, 761.121412 • Magnetic resonance (MR), contrast enhancement, 761.121411, 761.121412 • Magnetic resonance (MR), vascular studies




This article has been cited by other articles:


Home page
RadiologyHome page
J. M. Willatt, H. K. Hussain, S. Adusumilli, and J. A. Marrero
MR Imaging of Hepatocellular Carcinoma in the Cirrhotic Liver: Challenges and Controversies
Radiology, May 1, 2008; 247(2): 311 - 330.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. L. Chu, B. N. Joe, A. C. A. Westphalen, E. M. Webb, F. V. Coakley, and B. M. Yeh
Patient-specific Time to Peak Abdominal Organ Enhancement Varies with Time to Peak Aortic Enhancement at MR Imaging
Radiology, December 1, 2007; 245(3): 779 - 787.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
S. N. Gandhi, M. A. Brown, J. G. Wong, D. A. Aguirre, and C. B. Sirlin
MR Contrast Agents for Liver Imaging: What, When, How
RadioGraphics, November 1, 2006; 26(6): 1621 - 1636.
[Abstract] [Full Text] [PDF]