|
|
||||||||
Genitourinary Imaging |
1 From the Institute of Diagnostic Radiology (T.M.K., S.C.A.M., G.E., K.T., B.M., R.A.K.H.) and Department of Obstetrics (A.R., R.H.), University Hospital, Zurich, Switzerland; and Department of Biostatistics, University of Zurich, Switzerland (B.S.). Received October 10, 2001; revision requested December 20; final revision received August 22, 2002; accepted August 27. Supported in part by a grant from the EMDO-Foundation, Switzerland. Address correspondence to R.A.K.H., Department of Radiology, Kantonsspital Baden, CH-5404 Baden, Switzerland (e-mail: rahel.kubik@ksb.ch).
PURPOSE: To establish obstetric magnetic resonance (MR) pelvimetric reference values in a large study population and stratify them according to delivery modality and to determine the intra- and interobserver error and intraindividual variability of MR pelvimetric assessment in volunteers.
MATERIALS AND METHODS: MR pelvimetric data were retrospectively reviewed in 781 women (mean age, 28.9 years ± 5.2 [SD]) clinically referred, and the data were correlated to obstetric history to derive normative values. Five observers assessed results of multiple MR pelvimetric examinations in 10 female volunteers (mean age, 34.7 years ± 6.0; eight nullipara, two primipara) to provide data for measurement error analysis.
RESULTS: All values were higher in the spontaneous vaginal delivery subgroup (n = 100) and lower in the cesarean section or vacuum extraction subgroup (n = 130; intersubgroup difference, P < .001, Mann-Whitney U test). Pelvimetric parameters in the group undergoing spontaneous vaginal delivery were as follows: obstetric conjugate, 121.7 mm ± 8.6; interspinous distance, 112.3 mm ± 7.9; intertuberous distance, 120.6 mm ± 11.3; transverse diameter, 129.5 mm ± 8.7; and sagittal outlet, 115.8 mm ± 9.9. In the volunteer study, intraobserver, interobserver, and intraindividual reliabilities were high for the obstetric conjugate (0.940.96), interspinous distance (0.920.95), and transverse diameter (0.950.98) but low for intertuberous distance (0.640.87) and sagittal outlet (0.660.85).
CONCLUSION: Pelvimetric dimensions are smaller in women undergoing cesarean section or vacuum extraction than they are in those delivering vaginally. The pelvimetric parameters associated with the largest measurement errors are intertuberous distance and sagittal outlet.
© RSNA, 2003
Index terms: Pelvis, measurement, 44.92 Pelvis, MR, 44.121411, 44.121412, 44.121416, 44.92 Pregnancy, MR, 44.121411, 44.121412, 44.121416, 44.92
This article has been cited by other articles:
![]() |
M. E. Lockhart, J. R. Fielding, H. E. Richter, L. Brubaker, C. G. Salomon, W. Ye, C. M. Hakim, C. Y. Wai, A. H. Stolpen, and A. M. Weber Reproducibility of Dynamic MR Imaging Pelvic Measurements: A Multi-institutional Study Radiology, September 16, 2008; (2008) 2492072009. [Abstract] [Full Text] |
||||
![]() |
V. L. Handa, H. K. Pannu, S. Siddique, R. Gutman, J. VanRooyen, and G. Cundiff Architectural Differences in the Bony Pelvis of Women With and Without Pelvic Floor Disorders Obstet. Gynecol., December 1, 2003; 102(6): 1283 - 1290. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |