Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2273020299
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nakamoto, Y.
Right arrow Articles by Wahl, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nakamoto, Y.
Right arrow Articles by Wahl, R. L.
(Radiology 2003;227:817-824.)
© RSNA, 2003


Experimental Studies

Effects of Nonionic Intravenous Contrast Agents at PET/CT Imaging: Phantom and Canine Studies1

Yuji Nakamoto, MD, PhD, Bennett B. Chin, MD, Dara L. Kraitchman, VMD, PhD, Leo P. Lawler, MD, PhD, Laura T. Marshall, BS and Richard L. Wahl, MD

1 From the Department of Radiology, Division of Nuclear Medicine, Johns Hopkins University Hospital, 601 N Caroline St, Rm 3223, Baltimore, MD 21287-0817. Received March 27, 2002; revision requested June 10; final revision received October 11; accepted October 23. Address correspondence to R.L.W. (e-mail: rwahl@jhmi.edu).

PURPOSE: To investigate the effects of intravenous contrast agents on quantitative values obtained with a combined positron emission tomographic (PET) and computed tomographic (CT) scanner by using several phantoms and a dog.

MATERIALS AND METHODS: Fluorine 18 fluorodeoxyglucose (FDG) was mixed with different concentrations of contrast agent with the same syringe (phantom 1), and the phantom was scanned. After image reconstruction with various attenuation maps, radioactivity concentrations were compared. Then, FDG solutions with (phantom 2) or surrounded by (phantom 3) various concentrations of contrast agent were scanned repeatedly, and radioactivity concentration was compared. Finally, PET and CT with and without contrast agent were performed in a dog. PET images were reconstructed by using different attenuation maps, and radioactivity concentrations were compared. The radioactivity concentration on germanium 68 (68Ge)-based corrected images was regarded as standard, and percentage bias, defined as difference divided by measured activity of 68Ge-based corrected images, was assessed. The relationship between the concentration of contrast agent and the percentage bias was assessed with the Pearson coefficient r, and the significance of correlations was evaluated with the Fisher z test.

RESULTS: All phantom studies demonstrated that presence of a contrast agent resulted in overestimation of emission data. CT numbers showed a strong positive correlation with the percentage bias in phantoms 2 (r = 0.999) and 3 (r = 0.987); the maximum percentage bias at 1,360 HU reached approximately 45%. These effects were independent of FDG concentration. In a canine model, presence of a contrast agent also increased emission activity, but the percentage bias was less than 15% in the liver and smaller in all other organs except the kidney (26%).

CONCLUSION: High concentrations of a contrast agent caused considerable overestimation of apparent tracer activity in phantom studies; however, the emission bias was relatively modest in vivo, except in areas with very high contrast agent concentrations.

© RSNA, 2003

Index terms: Animals • Computed tomography (CT), contrast media, **.12111, **.12112, **.121142 • Contrast media, effects • Phantoms • Positron emission tomography (PET), **.12163, **.12166




This article has been cited by other articles:


Home page
JNMHome page
L.-F. de Geus-Oei, D. Vriens, H. W.M. van Laarhoven, W. T.A. van der Graaf, and W. J.G. Oyen
Monitoring and Predicting Response to Therapy with 18F-FDG PET in Colorectal Cancer: A Systematic Review
J. Nucl. Med., May 1, 2009; 50(Suppl_1): 43S - 54S.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Martinez-Moller, M. Souvatzoglou, G. Delso, R. A. Bundschuh, C. Chefd'hotel, S. I. Ziegler, N. Navab, M. Schwaiger, and S. G. Nekolla
Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data
J. Nucl. Med., April 1, 2009; 50(4): 520 - 526.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
M. Allen-Auerbach and W. A. Weber
Measuring Response with FDG-PET: Methodological Aspects
Oncologist, April 1, 2009; 14(4): 369 - 377.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. J. Gollub, R. Hong, D. M. Sarasohn, and T. Akhurst
Limitations of CT During PET/CT
J. Nucl. Med., October 1, 2007; 48(10): 1583 - 1591.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. A. Weber and R. Figlin
Monitoring Cancer Treatment with PET/CT: Does It Make a Difference?
J. Nucl. Med., January 1, 2007; 48(1_suppl): 36S - 44S.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Kuehl, P. Veit, S. J. Rosenbaum, A. Bockisch, and G. Antoch
Can PET/CT Replace Separate Diagnostic CT for Cancer Imaging? Optimizing CT Protocols for Imaging Cancers of the Chest and Abdomen
J. Nucl. Med., January 1, 2007; 48(1_suppl): 45S - 57S.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
B. Rodriguez-Vigil, N. Gomez-Leon, I. Pinilla, D. Hernandez-Maraver, J. Coya, L. Martin-Curto, and R. Madero
PET/CT in Lymphoma: Prospective Study of Enhanced Full-Dose PET/CT Versus Unenhanced Low-Dose PET/CT
J. Nucl. Med., October 1, 2006; 47(10): 1643 - 1648.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. A. Blake, A. Singh, B. N. Setty, J. Slattery, M. Kalra, M. M. Maher, D. V. Sahani, A. J. Fischman, and P. R. Mueller
Pearls and Pitfalls in Interpretation of Abdominal and Pelvic PET-CT
RadioGraphics, September 1, 2006; 26(5): 1335 - 1353.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
D. Delbeke, R. E. Coleman, M. J. Guiberteau, M. L. Brown, H. D. Royal, B. A. Siegel, D. W. Townsend, L. L. Berland, J. A. Parker, G. Zubal, et al.
Procedure Guideline for SPECT/CT Imaging 1.0
J. Nucl. Med., July 1, 2006; 47(7): 1227 - 1234.
[Full Text] [PDF]


Home page
JNMHome page
D. Delbeke, R. E. Coleman, M. J. Guiberteau, M. L. Brown, H. D. Royal, B. A. Siegel, D. W. Townsend, L. L. Berland, J. A. Parker, K. Hubner, et al.
Procedure Guideline for Tumor Imaging with 18F-FDG PET/CT 1.0
J. Nucl. Med., May 1, 2006; 47(5): 885 - 895.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
O. Mawlawi, J. J. Erasmus, R. F. Munden, T. Pan, A. E. Knight, H. A. Macapinlac, D. A. Podoloff, and M. Chasen
Quantifying the Effect of IV Contrast Media on Integrated PET/CT: Clinical Evaluation
Am. J. Roentgenol., February 1, 2006; 186(2): 308 - 319.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Ames, T. Blodgett, and C. Meltzer
18F-FDG Uptake in an Ovary Containing a Hemorrhagic Corpus Luteal Cyst: False-Positive PET/CT in a Patient with Cervical Carcinoma
Am. J. Roentgenol., October 1, 2005; 185(4): 1057 - 1059.
[Full Text] [PDF]


Home page
JNMHome page
R. E. Coleman, D. Delbeke, M. J. Guiberteau, P. S. Conti, H. D. Royal, J. C. Weinreb, B. A. Siegel, M. F. Federle, D. W. Townsend, and L. L. Berland
Concurrent PET/CT with an Integrated Imaging System: Intersociety Dialogue from the Joint Working Group of the American College of Radiology, the Society of Nuclear Medicine, and the Society of Computed Body Tomography and Magnetic Resonance
J. Nucl. Med., July 1, 2005; 46(7): 1225 - 1239.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. F. Branstetter IV, T. M. Blodgett, L. A. Zimmer, C. H. Snyderman, J. T. Johnson, S. Raman, and C. C. Meltzer
Head and Neck Malignancy: Is PET/CT More Accurate than PET or CT Alone?
Radiology, May 1, 2005; 235(2): 580 - 586.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
Y.-Y. Yau, W.-S. Chan, Y.-M. Tam, P. Vernon, S. Wong, M. Coel, and S. K.-F. Chu
Application of Intravenous Contrast in PET/CT: Does It Really Introduce Significant Attenuation Correction Error?
J. Nucl. Med., February 1, 2005; 46(2): 283 - 291.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Gutzeit, G. Antoch, H. Kuhl, T. Egelhof, M. Fischer, E. Hauth, S. Goehde, A. Bockisch, J. Debatin, and L. Freudenberg
Unknown Primary Tumors: Detection with Dual-Modality PET/CT--Initial Experience
Radiology, January 1, 2005; 234(1): 227 - 234.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
G. Antoch, L. S. Freudenberg, T. Beyer, A. Bockisch, and J. F. Debatin
To Enhance or Not to Enhance? 18F-FDG and CT Contrast Agents in Dual-Modality 18F-FDG PET/CT
J. Nucl. Med., January 1, 2004; 45(90010): 56S - 65.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. L. Wahl
Why Nearly All PET of Abdominal and Pelvic Cancers Will Be Performed as PET/CT
J. Nucl. Med., January 1, 2004; 45(90010): 82S - 95.
[Abstract] [Full Text] [PDF]