Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print May 8, 2003, 10.1148/radiol.2281020693
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2281020693v1
228/1/251    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kalra, M. K.
Right arrow Articles by Saini, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kalra, M. K.
Right arrow Articles by Saini, S.
(Radiology 2003;228:251-256.)
© RSNA, 2003


Technical Developments

Low-Dose CT of the Abdomen: Evaluation of Image Improvement with Use of Noise Reduction Filters—Pilot Study1

Mannudeep K. Kalra, MD, Michael M. Maher, MD, FRCR, Dushyant V. Sahani, MD, Michael A. Blake, MRCP, FFR (RCSI), FRCR, Peter F. Hahn, MD, PhD, Gopal B. Avinash, PhD, Thomas L. Toth, AAS, Elkan Halpern, PhD and Sanjay Saini, MD

1 From the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, White 270-E, 55 Fruit St, Boston, MA 02114 (M.K.K., M.M.M., D.V.S., M.A.B., P.F.H., E.H., S.S.); and GE Medical Systems, Milwaukee, Wis (G.B.A., T.L.T.). Received June 10, 2002; revision requested August 20; revision received September 5; accepted October 24. Supported in part by a grant from GE Medical Systems. Address correspondence to S.S. (e-mail: ssaini@partners.org).

A prospective assessment of improvement in image quality at low–radiation-dose computed tomography (CT) of the abdomen by using noise reduction filters was performed. CT images acquired at standard and 50% reduced tube current were processed with six noise reduction filters and evaluated by three radiologists for image noise, sharpness, contrast, and overall image quality in terms of abdominal organ depiction. Quantitative image noise and contrast-to-noise ratio were measured. Baseline low-dose CT images were significantly worse than standard-dose CT images (P < .05). A statistically significant reduction of noise in low-dose images processed with three filters was noted. In conclusion, use of noise reduction filters decreased image noise at low-dose CT.

© RSNA, 2003

Index terms: Abdomen, CT, 70.12112, 76.12112 • Computed tomography (CT), image processing • Computed tomography (CT), image quality • Computed tomography (CT), radiation exposure • Radiations, exposure to patients and personnel




This article has been cited by other articles:


Home page
RadiologyHome page
D. Marin, R. C. Nelson, E. Samei, E. K. Paulson, L. M. Ho, D. T. Boll, D. M. DeLong, T. T. Yoshizumi, and S. T. Schindera
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multidetector CT during Late Hepatic Arterial Phase for Detection--Initial Clinical Experience
Radiology, June 1, 2009; 251(3): 771 - 779.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Kubo, Y. Ohno, S. Gautam, P.-J. P. Lin, H.-U. Kauczor, H. Hatabu, and iLEAD Study Group
Use of 3D Adaptive Raw-Data Filter in CT of the Lung: Effect on Radiation Dose Reduction
Am. J. Roentgenol., October 1, 2008; 191(4): W167 - W174.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.B. Smith, W.P. Dillon, R. Gould, and M. Wintermark
Radiation Dose-Reduction Strategies for Neuroradiology CT Protocols
AJNR Am. J. Neuroradiol., October 1, 2007; 28(9): 1628 - 1632.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
A J Van Der Molen, W J H Veldkamp, and J Geleijns
16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys
Br. J. Radiol., April 1, 2007; 80(952): 248 - 255.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Nakayama, K. Awai, Y. Funama, M. Hatemura, M. Imuta, T. Nakaura, D. Ryu, S. Morishita, S. Sultana, N. Sato, et al.
Abdominal CT with Low Tube Voltage: Preliminary Observations about Radiation Dose, Contrast Enhancement, Image Quality, and Noise
Radiology, December 1, 2005; 237(3): 945 - 951.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. M. R. Rizzo, M. K. Kalra, B. Schmidt, R. Raupach, M. M. Maher, M. A. Blake, and S. Saini
CT Images of Abdomen and Pelvis: Effect of Nonlinear Three-dimensional Optimized Reconstruction Algorithm on Image Quality and Lesion Characteristics
Radiology, October 1, 2005; 237(1): 309 - 315.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Yee, N. N. Kumar, S. Godara, J. A. Casamina, R. Hom, G. Galdino, P. Dell, and D. Liu
Extracolonic Abnormalities Discovered Incidentally at CT Colonography in a Male Population
Radiology, August 1, 2005; 236(2): 519 - 526.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, R. S. Kamath, T. Horiuchi, T. L. Toth, E. F. Halpern, and S. Saini
Sixteen-Detector Row CT of Abdomen and Pelvis: Study for Optimization of Z-Axis Modulation Technique Performed in 153 Patients
Radiology, October 1, 2004; 233(1): 241 - 249.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, M. A. Blake, B. C. Lucey, K. Karau, T. L. Toth, G. Avinash, E. F. Halpern, and S. Saini
Detection and Characterization of Lesions on Low-Radiation-Dose Abdominal CT Images Postprocessed with Noise Reduction Filters
Radiology, September 1, 2004; 232(3): 791 - 797.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, T. L. Toth, R. S. Kamath, E. F. Halpern, and S. Saini
Radiation from "Extra" Images Acquired with Abdominal and/or Pelvic CT: Effect of Automatic Tube Current Modulation
Radiology, August 1, 2004; 232(2): 409 - 414.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, T. L. Toth, L. M. Hamberg, M. A. Blake, J.-A. Shepard, and S. Saini
Strategies for CT Radiation Dose Optimization
Radiology, March 1, 2004; 230(3): 619 - 628.
[Abstract] [Full Text] [PDF]