|
|
||||||||
Technical Developments |
1 From the Department of Radiology, Founders 202, Massachusetts General Hospital and Harvard Medical School, 32 Fruit St, Boston, MA 02114 (M.K.K., C.W., M.M.M., A.S., E.H., S.S., J.S.), and GE Medical Systems, Waukesha, Wis (G.B.A., K.K., T.L.T.). Supported in part by a grant from GE Medical Systems. Received May 23, 2002; revision requested July 16; final revision received October 11; accepted October 23. Address correspondence to J.S. (e-mail: jshepard@partners.org).
Effect of noise reduction filters on chest computed tomographic (CT) images acquired with 50% radiation dose reduction was evaluated. Two sets of images were acquired with multidetector row CT at standard (220280 mA) and 50% reduced (110140 mA) tube current at the level of the carina. After postprocessing with six noise reduction filters, images were compared with baseline standard-dose images for noise, sharpness, and contrast in lungs, mediastinum, and chest wall. Quantitative image noise was measured in descending thoracic aorta. Modulation transfer functions were calculated from CT images of 50-µm wire. Noise reduction filters reduced image noise on low-radiation-dose chest CT images, with some compromise in image sharpness and contrast assessed qualitatively, and slightly altered modulation transfer function at higher spatial frequencies.
© RSNA, 2003
Index terms: Computed tomography (CT), radiation exposure Filters, radiographic Thorax, CT, 60.12112, 60.12115
This article has been cited by other articles:
![]() |
T. Kubo, Y. Ohno, S. Gautam, P.-J. P. Lin, H.-U. Kauczor, H. Hatabu, and iLEAD Study Group Use of 3D Adaptive Raw-Data Filter in CT of the Lung: Effect on Radiation Dose Reduction Am. J. Roentgenol., October 1, 2008; 191(4): W167 - W174. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kubo, P.-J. P. Lin, W. Stiller, M. Takahashi, H.-U. Kauczor, Y. Ohno, and H. Hatabu Radiation Dose Reduction in Chest CT: A Review Am. J. Roentgenol., February 1, 2008; 190(2): 335 - 343. [Abstract] [Full Text] [PDF] |
||||
![]() |
K Imai, M Ikeda, S Wada, Y Enchi, and T Niimi Analysis of streak artefacts on CT images using statistics of extremes Br. J. Radiol., November 1, 2007; 80(959): 911 - 918. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.B. Smith, W.P. Dillon, R. Gould, and M. Wintermark Radiation Dose-Reduction Strategies for Neuroradiology CT Protocols AJNR Am. J. Neuroradiol., October 1, 2007; 28(9): 1628 - 1632. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Nakayama, K. Awai, Y. Funama, M. Hatemura, M. Imuta, T. Nakaura, D. Ryu, S. Morishita, S. Sultana, N. Sato, et al. Abdominal CT with Low Tube Voltage: Preliminary Observations about Radiation Dose, Contrast Enhancement, Image Quality, and Noise Radiology, December 1, 2005; 237(3): 945 - 951. [Abstract] [Full Text] [PDF] |
||||
![]() |
M A Lewis and S Edyvean Patient dose reduction in CT Br. J. Radiol., October 1, 2005; 78(934): 880 - 883. [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, S. Rizzo, M. M. Maher, E. F. Halpern, T. L. Toth, J.-A. O. Shepard, and S. L. Aquino Chest CT Performed with Z-Axis Modulation: Scanning Protocol and Radiation Dose Radiology, October 1, 2005; 237(1): 303 - 308. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. R. Rizzo, M. K. Kalra, B. Schmidt, R. Raupach, M. M. Maher, M. A. Blake, and S. Saini CT Images of Abdomen and Pelvis: Effect of Nonlinear Three-dimensional Optimized Reconstruction Algorithm on Image Quality and Lesion Characteristics Radiology, October 1, 2005; 237(1): 309 - 315. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, M. M. Maher, R. S. Kamath, T. Horiuchi, T. L. Toth, E. F. Halpern, and S. Saini Sixteen-Detector Row CT of Abdomen and Pelvis: Study for Optimization of Z-Axis Modulation Technique Performed in 153 Patients Radiology, October 1, 2004; 233(1): 241 - 249. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, M. M. Maher, M. A. Blake, B. C. Lucey, K. Karau, T. L. Toth, G. Avinash, E. F. Halpern, and S. Saini Detection and Characterization of Lesions on Low-Radiation-Dose Abdominal CT Images Postprocessed with Noise Reduction Filters Radiology, September 1, 2004; 232(3): 791 - 797. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, M. M. Maher, T. L. Toth, R. S. Kamath, E. F. Halpern, and S. Saini Radiation from "Extra" Images Acquired with Abdominal and/or Pelvic CT: Effect of Automatic Tube Current Modulation Radiology, August 1, 2004; 232(2): 409 - 414. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Cody, D. M. Moxley, K. T. Krugh, J. C. O'Daniel, L. K. Wagner, and F. Eftekhari Strategies for Formulating Appropriate MDCT Techniques When Imaging the Chest, Abdomen, and Pelvis in Pediatric Patients Am. J. Roentgenol., April 1, 2004; 182(4): 849 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, M. M. Maher, T. L. Toth, L. M. Hamberg, M. A. Blake, J.-A. Shepard, and S. Saini Strategies for CT Radiation Dose Optimization Radiology, March 1, 2004; 230(3): 619 - 628. [Abstract] [Full Text] [PDF] |
||||