Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print May 20, 2003, 10.1148/radiol.2281020375
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2281020375v1
228/1/284    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fellner, F. A.
Right arrow Articles by Cavallaro, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fellner, F. A.
Right arrow Articles by Cavallaro, A.
(Radiology 2003;228:284-289.)
© RSNA, 2003


Technical Developments

Peripheral Vessels: MR Angiography with Dedicated Phased-Array Coil with Large–Field-of-View Adapter—Feasibility Study1

Franz A. Fellner, MD, Martin Requardt, PhD, Werner Lang, MD, Claudia Fellner, PhD, Werner Bautz, MD and Alexander Cavallaro, MD

1 From the Institute of Diagnostic Radiology (F.A.F., C.F., W.B., A.C.) and Department of Surgery (W.L.), Friedrich-Alexander-University Erlangen-Nürnberg, Maximiliansplatz 1, D-91054 Erlangen, Germany; Institute of Neuroradiology, Oberösterreichische Landesnervenklinik Wagner Jauregg, Linz, Austria (F.A.F.); and Department of Magnetic Resonance, Siemens Medical Solutions, Erlangen, Germany (M.R.). Received April 8, 2002; revision requested July 3; final revision received October 8; accepted October 14. Address correspondence to F.A.F. (e-mail: franz.fellner@gespag.at).

At magnetic resonance (MR) angiography with conventional phased-array coils, visualization of the vascular tree from the infrarenal aorta to the pedal arch is not possible in most patients. For this purpose, the authors developed a dedicated adapter with a large field of view that allows coverage of a body length of approximately 1,380 mm. Among five patients with peripheral arteriosclerotic disease, four underwent both conventional angiography and MR angiography. One hundred fourteen vascular segments from the infrarenal aorta to the feet were evaluated. Agreement between findings at conventional angiography and those at MR angiography was 94.7% (108 of 114) for all segments (96.1% [25 of 26] in the abdomen or pelvis, 97.5% [39 of 40] in the thigh, and 91.7% [44 of 48] in the calf or foot).

© RSNA, 2003

Index terms: Arteries, MR, 92.12942, 95.12942, 96.12942, 98.12942, 92.72, 95.72, 96.72, 98.72 • Arteries, peripheral, 92.12942, 95.12942, 96.12942, 98.12942, 92.72, 95.72, 96.72, 98.72 • Magnetic resonance (MR), vascular studies, 92.12942, 95.12942, 96.12942, 98.12942




This article has been cited by other articles:


Home page
RadiologyHome page
R. Janka, C. Fellner, E. Wenkel, W. Lang, W. Bautz, and F. A. Fellner
Contrast-enhanced MR Angiography of Peripheral Arteries including Pedal Vessels at 1.0 T: Feasibility Study with Dedicated Peripheral Angiography Coil
Radiology, April 1, 2005; 235(1): 319 - 326.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2003 by the Radiological Society of North America.