Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2282020471
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boone, J. M.
Right arrow Articles by Wootton-Gorges, S. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boone, J. M.
Right arrow Articles by Wootton-Gorges, S. L.
(Radiology 2003;228:352-360.)
© RSNA, 2003


Pediatric Imaging

Dose Reduction in Pediatric CT: A Rational Approach1

John M. Boone, PhD, Estella M. Geraghty, MD, MS, J. Anthony Seibert, PhD and Sandra L. Wootton-Gorges, MD

1 From the Department of Radiology, University of California Davis Medical Center, Research Imaging Center, 4701 X St, Sacramento, CA 95817. Received April 25, 2002; revision requested June 21; final revision received September 24; accepted November 5. Supported in part by grants from the California Breast Cancer Research Program (7EB-0075) and the National Cancer Institute (R01-CA89260). Address correspondence to J.M.B. (e-mail: jmboone@ucdavis.edu).

PURPOSE: To determine size-dependent technique factors for pediatric computed tomography (CT) by using physically measured objective data.

MATERIALS AND METHODS: Six phantom cylinders (10–32 cm in diameter) were scanned with a clinical multi–detector row CT scanner. CT noise was statistically characterized for CT technique factors from 80 to 140 kVp and from 10 to 300 mAs. Dose measurements were performed with each phantom. Dilute iodine and tissue contrast were determined with computer calculations validated with measured data. The dose, noise, and contrast data were computer fit, and pediatric CT technique factors (milliampere seconds) necessary to maintain the contrast-to-noise ratio (CNR) were computed.

RESULTS: As compared with that in a reference cylindric adult abdomen of 28 cm in diameter, CNR was maintained at a constant level in pediatric patients of 25, 20, and 15 cm in diameter, respectively, when milliampere second values of 0.557, 0.196, and 0.054 of the adult milliampere second values were used. The corresponding doses were reduced to 0.642, 0.287, and 0.090 of the 28-cm-diameter adult dose, respectively. CT techniques for examination of pediatric heads measuring 15 and 13 cm, respectively, can involve the use of milliampere second values of 0.572 and 0.366 of those used for examination of a standard 17-cm-diameter adult head.

CONCLUSION: CT technique charts for pediatric abdominal and head examinations were produced on the basis of physically measured data; use of these tables will enable pediatric radiation dose to be reduced while CNR is preserved.

© RSNA, 2003

Index terms: Abdomen, CT, 78.1211 • Computed tomography (CT), in infants and children • Computed tomography (CT), radiation exposure • Head, CT, 18.1211, 28.1211 • Radiations, exposure to patients and personnel




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. Herzog, D. M. Mulvihill, S. A. Nguyen, G. Savino, B. Schmidt, P. Costello, T. J. Vogl, and U. J. Schoepf
Pediatric Cardiovascular CT Angiography: Radiation Dose Reduction Using Automatic Anatomic Tube Current Modulation
Am. J. Roentgenol., May 1, 2008; 190(5): 1232 - 1240.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. G. Eichhorn, C. Jourdan, S. L. Hill, S. V. Raman, J. P. Cheatham, and F. R. Long
CT of Pediatric Vascular Stents Used to Treat Congenital Heart Disease
Am. J. Roentgenol., May 1, 2008; 190(5): 1241 - 1246.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
S. Masciari, A. D. Van den Abbeele, L. R. Diller, I. Rastarhuyeva, J. Yap, K. Schneider, L. Digianni, F. P. Li, J. F. Fraumeni Jr, S. Syngal, et al.
F18-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography Screening in Li-Fraumeni Syndrome
JAMA, March 19, 2008; 299(11): 1315 - 1319.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
M. Tubiana, S. Nagataki, L. E. Feinendegen, D. A. Dimitroyannis, D. P. Frush, M. J. Goske, M. Hernanz-Schulman, P. Soyer, H. Varnholt, D. J. Brenner, et al.
Computed Tomography and Radiation Exposure
N. Engl. J. Med., February 21, 2008; 358(8): 850 - 853.
[Full Text] [PDF]


Home page
RadiologyHome page
S. T. Schindera, R. C. Nelson, S. Mukundan Jr, E. K. Paulson, T. A. Jaffe, C. M. Miller, D. M. DeLong, K. Kawaji, T. T. Yoshizumi, and E. Samei
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multi Detector Row CT for Enhanced Detection Phantom Study
Radiology, December 1, 2007; 246(1): 125 - 132.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Bohy, V. de Maertelaer, A. Roquigny, C. Keyzer, D. Tack, and P. A. Gevenois
Multidetector CT in Patients Suspected of Having Lumbar Disk Herniation: Comparison of Standard-Dose and Simulated Low-Dose Techniques
Radiology, August 1, 2007; 244(2): 524 - 531.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
A J Van Der Molen, W J H Veldkamp, and J Geleijns
16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys
Br. J. Radiol., April 1, 2007; 80(952): 248 - 255.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P C Shrimpton, M C Hillier, M A Lewis, and M Dunn
National survey of doses from CT in the UK: 2003
Br. J. Radiol., December 1, 2006; 79(948): 968 - 980.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. C. Chan, B. N. Joe, F. V. Coakley, E. L. Prien Jr, R. G. Gould, S. Prevrhal, W. C. Barber, K. S. Kirkwood, A. Qayyum, and B. M. Yeh
Gallstone Detection at CT in Vitro: Effect of Peak Voltage Setting.
Radiology, November 1, 2006; 241(2): 546 - 553.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. H. McCollough, M. R. Bruesewitz, and J. M. Kofler Jr
CT Dose Reduction and Dose Management Tools: Overview of Available Options.
RadioGraphics, March 1, 2006; 26(2): 503 - 512.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Funama, K. Awai, Y. Nakayama, K. Kakei, N. Nagasue, M. Shimamura, N. Sato, S. Sultana, S. Morishita, and Y. Yamashita
Radiation Dose Reduction without Degradation of Low-Contrast Detectability at Abdominal Multisection CT with a Low-Tube Voltage Technique: Phantom Study
Radiology, December 1, 2005; 237(3): 905 - 910.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. H. Mulkens, P. Bellinck, M. Baeyaert, D. Ghysen, X. Van Dijck, E. Mussen, C. Venstermans, and J.-L. Termote
Use of an Automatic Exposure Control Mechanism for Dose Optimization in Multi-Detector Row CT Examinations: Clinical Evaluation
Radiology, October 1, 2005; 237(1): 213 - 223.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. Boone
What Parameters Are Most Accurate in Predicting Appropriate Technique Factors for CT Scanning?
Radiology, August 1, 2005; 236(2): 377 - 378.
[Full Text] [PDF]


Home page
RadiologyHome page
J. Menke
Comparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults
Radiology, August 1, 2005; 236(2): 565 - 571.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Ledenius, M. Gustavsson, S. Johansson, F. Stalhammar, J. Soderberg, L. M. Wiklund, and A. Thilander Klang
A method of predicting the image noise in paediatric multi-slice computed tomography images
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 313 - 316.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Irie and H. Inoue
Individual Modulation of the Tube Current-Seconds to Achieve Similar Levels of Image Noise in Contrast-Enhanced Abdominal CT
Am. J. Roentgenol., May 1, 2005; 184(5): 1514 - 1518.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
L. M. Fayad, P. Johnson, and E. K. Fishman
Multidetector CT of Musculoskeletal Disease in the Pediatric Patient: Principles, Techniques, and Clinical Applications
RadioGraphics, May 1, 2005; 25(3): 603 - 618.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. J. Siegel, B. Schmidt, D. Bradley, C. Suess, and C. Hildebolt
Radiation Dose and Image Quality in Pediatric CT: Effect of Technical Factors and Phantom Size and Shape
Radiology, November 1, 2004; 233(2): 515 - 522.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2003 by the Radiological Society of North America.