Experimental Studies |
1 From the Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Ave, Boston, MA 02215. Received June 21, 2002; revision requested August 21; final revision received January 13, 2003; accepted January 27. Address correspondence to R.G.S. (e-mail: rsheiman@bidmc.harvard.edu).
PURPOSE: To evaluate the feasibility of helical computed tomography (CT) as an imaging modality for depicting active colonic hemorrhage in a swine model.
MATERIALS AND METHODS: Controlled extravasation of contrast materialenhanced blood (CEB) from 140 to 180 HU and at varying rates (0.31.0 mL/min) was performed during a 30-second period by using a microcatheter system placed within the descending colon of 14 swine. CEB was immediately followed by extravasation of unopacified blood at the same location and rate during serial helical CT imaging of the extravasation site. Region-of-interest analysis allowed quantification of the dilution of extravasated CEB as a function of time that was then modeled mathematically based on iodine mass and volume balances. Nonlinear least squares analysis was performed to optimize fitting of the model to experimental data, with a maximum regression value (R2) of 1.0 indicating a perfect fit. This model enabled the computer simulation of CT imaging of multiple combinations of bleeding rates and CEB attenuation to determine the sensitivity of helical CT for depicting active colonic bleeding.
RESULTS: Sixteen swine examinations yielded 16 CEB dilution curves. An excellent fit of the model to each dilution curve was achieved, as indicated by a mean R2 value of 0.8402. Swine examinations alone showed that targeted CT could depict CEB as low as 111 HU extravasating at a rate of 0.3 mL/min. Simulations that were based on helical CT images with 5-mm collimation reconstructed every 3 mm and that used the model indicated bleeding rates below 0.4 mL/min are detectable, provided peak aortic enhancement reaches 100 HU.
CONCLUSION: Conservatively, helical CT has the potential to depict active colonic hemorrhage at rates of 0.5 mL/min or less.
© RSNA, 2003
Index terms: Animals Colon, CT, 75.12115 Computed tomography (CT), experimental studies Hemorrhage, CT
Related Article
Radiology 2003 228: 599-600.
This article has been cited by other articles:
![]() |
D J B Marks, A Prodromou, A Silvanto, A Cox, F Pakzad, M Train, and I C Mitchell Ileal MALT lymphoma causing massive gastrointestinal haemorrhage revealed on computed tomography angiography Postgrad. Med. J., March 1, 2009; 85(1001): 163 - 165. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. G. Sheiman and A. Sitek Feasibility of Measurement of Pancreatic Perfusion Parameters with Single-Compartment Kinetic Model Applied to Dynamic Contrast-enhanced CT Images Radiology, December 1, 2008; 249(3): 878 - 882. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. I. Zink, S. K. Ohki, B. Stein, D. A. Zambuto, R. J. Rosenberg, J. J. Choi, and D. S. Tubbs Noninvasive Evaluation of Active Lower Gastrointestinal Bleeding: Comparison Between Contrast-Enhanced MDCT and 99mTc-Labeled RBC Scintigraphy Am. J. Roentgenol., October 1, 2008; 191(4): 1107 - 1114. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Roy-Choudhury and S. Karandikar Multidetector CT of Acute Gastrointestinal Bleeding Radiology, January 1, 2008; 246(1): 336 - 336. [Full Text] [PDF] |
||||
![]() |
S. H. Roy-Choudhury, D. J. Gallacher, J. Pilmer, S. Rankin, G. Fowler, J. Steers, R. Dourado, P. Woodburn, and A. Adam Relative Threshold of Detection of Active Arterial Bleeding: In Vitro Comparison of MDCT and Digital Subtraction Angiography Am. J. Roentgenol., November 1, 2007; 189(5): W238 - W246. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Laing, T. Tobias, D. I. Rosenblum, W. L. Banker, L. Tseng, and S. W. Tamarkin Acute Gastrointestinal Bleeding: Emerging Role of Multidetector CT Angiography and Review of Current Imaging Techniques RadioGraphics, July 1, 2007; 27(4): 1055 - 1070. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Anthony and R Uberoi The current status of imaging in acute gastrointestinal haemorrhage Imaging, December 1, 2006; 18(4): 193 - 197. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Yoon, Y. Y. Jeong, S. S. Shin, H. S. Lim, S. G. Song, N. G. Jang, J. K. Kim, and H. K. Kang Acute Massive Gastrointestinal Bleeding: Detection and Localization with Arterial Phase Multi-Detector Row Helical CT Radiology, April 1, 2006; 239(1): 160 - 167. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Sitek and R. G. Sheiman Small-Bowel Perfusion Measurement: Feasibility with Single-Compartment Kinetic Model Applied to Dynamic Contrast-enhanced CT Radiology, November 1, 2005; 237(2): 670 - 674. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Summers Science to Practice: Detection of Active Colonic Hemorrhage with Use of Helical CT: Findings in a Swine Model Radiology, September 1, 2003; 228(3): 599 - 600. [Full Text] [PDF] |
||||