1 From the Departments of Radiology (H.T.W.M., S.G.J., C.A.M., Y.L., A.M.A., R.D.T.) and Radiation Oncology (R.C.M.), Indiana University School of Medicine, Indianapolis. Received July 11, 2002; revision requested August 29; final revision received February 11, 2003; accepted March 3. Address correspondence to H.T.W.M., 11224 Clarkston Rd, Zionsville, IN 46077 (e-mail: hwinermu@iupui.edu).
PURPOSE: To determine how volume measurements of simulated and clinical lung tumors at standard computed tomographic (CT) lung window and level settings vary with section width and to derive and apply compensatory equations.
MATERIALS AND METHODS: Spherical simulated tumors of varying diameters were imaged with varying CT section widths, the images were displayed on a workstation, the cross-sectional area of the tumor on each section was measured by using elliptical and perimeter methods, and the areas were integrated to compute tumor volume. The actual and measured tumor volumes for differing section widths and tumor diameters were compared, and compensatory equations were derived. The equations were applied to contemporaneous chest CT images obtained in patients with stage I lung cancer, and the difference between thick- and thin-sectionderived volumes before and after application of the equations was determined.
RESULTS: All simulated tumor volumes were overestimated 11%278%; overestimation varied directly with section width and inversely with tumor diameter. With both measurement methods, mean thin-section volumes of clinical tumors in 55 patients were significantly smaller (P < .01) than mean thick-section volumes: Mean elliptical measurements were 15,025 mm3 (thin) and 18,037 mm3 (thick), with a 20.0% difference; mean perimeter measurements were 16,164 mm3 (thin) and 20,718 mm3 (thick), with a 22.2% difference. The thin-sectiontothick-section volume difference was larger for the smallest tumors. Thin-section volumes were smaller than thick-section volumes in 53 patients with the elliptical method and in 51 patients with the perimeter method. Applying the equations decreased the difference between thick- and thin-section volumes in 37 (67%) of the 55 patients with the elliptical method and in 41 (74%) patients with the perimeter method. The mean thin-sectiontothick-section volume difference became nonsignificant with the perimeter method but remained significant with the elliptical method.
CONCLUSION: Measured lung tumor volumes vary significantly with varying CT section width; overestimation varies directly with section width and inversely with tumor size. Compensatory equations that are somewhat effective in reducing these effects can be derived.
© RSNA, 2003
Index terms: Computed tomography (CT), experimental studies, 60.12111, 60.12115 Lung neoplasms, 60.32 Lung neoplasms, CT, 60.12111, 60.12115 Thorax, CT, 60.12111, 60.12115
This article has been cited by other articles:
![]() |
B. Zhao, L. P. James, C. S. Moskowitz, P. Guo, M. S. Ginsberg, R. A. Lefkowitz, Y. Qin, G. J. Riely, M. G. Kris, and L. H. Schwartz Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non-Small Cell Lung Cancer Radiology, July 1, 2009; 252(1): 263 - 272. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. K. Park and J. Zhang Comments on "Distribution of Renal Tumor Growth Rates Determined by Using Serial Volumetric CT Measurements" Radiology, July 1, 2009; 252(1): 314 - 315. [Full Text] [PDF] |
||||
![]() |
P. J. Nietert, J. G. Ravenel, W. M. Leue, J. V. Miller, K. K. Taylor, E. S. Garrett-Mayer, and G. A. Silvestri Imprecision in Automated Volume Measurements of Pulmonary Nodules and Its Effect on the Level of Uncertainty in Volume Doubling Time Estimation Chest, June 1, 2009; 135(6): 1580 - 1587. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Gavrielides, L. M. Kinnard, K. J. Myers, and N. Petrick Noncalcified Lung Nodules: Volumetric Assessment with Thoracic CT Radiology, April 1, 2009; 251(1): 26 - 37. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Zhang, S. K. Kang, L. Wang, A. Touijer, and H. Hricak Distribution of Renal Tumor Growth Rates Determined by Using Serial Volumetric CT Measurements Radiology, January 1, 2009; 250(1): 137 - 144. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Ravenel, W. M. Leue, P. J. Nietert, J. V. Miller, K. K. Taylor, and G. A. Silvestri Pulmonary Nodule Volume: Effects of Reconstruction Parameters on Automated Measurements--A Phantom Study Radiology, May 1, 2008; 247(2): 400 - 408. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Suzuki, H. Jacobsson, T. Hatschek, M. R. Torkzad, K. Boden, Y. Eriksson-Alm, E. Berg, H. Fujii, A. Kubo, and L. Blomqvist Radiologic Measurements of Tumor Response to Treatment: Practical Approaches and Limitations RadioGraphics, March 1, 2008; 28(2): 329 - 344. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Gould, J. Fletcher, M. D. Iannettoni, W. R. Lynch, D. E. Midthun, D. P. Naidich, and D. E. Ost Evaluation of Patients With Pulmonary Nodules: When Is It Lung Cancer?: ACCP Evidence-Based Clinical Practice Guidelines (2nd Edition) Chest, September 1, 2007; 132(3_suppl): 108S - 130S. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Petrou, L. E. Quint, B. Nan, and L. H. Baker Pulmonary Nodule Volumetric Measurement Variability as a Function of CT Slice Thickness and Nodule Morphology Am. J. Roentgenol., February 1, 2007; 188(2): 306 - 312. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Jennings, H. T. Winer-Muram, M. Tann, J. Ying, and I. Dowdeswell Distribution of Stage I Lung Cancer Growth Rates Determined with Serial Volumetric CT Measurements Radiology, November 1, 2006; 241(2): 554 - 563. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. T. Winer-Muram The solitary pulmonary nodule. Radiology, April 1, 2006; 239(1): 34 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. R. Goodman, M. Gulsun, L. Washington, P. G. Nagy, and K. L. Piacsek Inherent Variability of CT Lung Nodule Measurements In Vivo Using Semiautomated Volumetric Measurements. Am. J. Roentgenol., April 1, 2006; 186(4): 989 - 994. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Tateishi, H. Uno, K. Yonemori, M. Satake, M. Takeuchi, and Y. Arai Prediction of Lung Adenocarcinoma Without Vessel Invasion: A CT Scan Volumetric Analysis Chest, November 1, 2005; 128(5): 3276 - 3283. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, T. Tongdee, R. Tongdee, K. Yeo, C. F. Hildebolt, and K. T. Bae Volumetric Measurement of Synthetic Lung Nodules with Multi-Detector Row CT: Effect of Various Image Reconstruction Parameters and Segmentation Thresholds on Measurement Accuracy Radiology, June 1, 2005; 235(3): 850 - 856. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Zhao, L. H. Schwartz, C. S. Moskowitz, L. Wang, M. S. Ginsberg, C. A. Cooper, L. Jiang, and J. P. Kalaigian Pulmonary Metastases: Effect of CT Section Thickness on Measurement--Initial Experience Radiology, March 1, 2005; 234(3): 934 - 939. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Jennings, H. T. Winer-Muram, R. D. Tarver, and M. O. Farber Lung Tumor Growth: Assessment with CT--Comparison of Diameter and Cross-sectional Area with Volume Measurements Radiology, June 1, 2004; 231(3): 866 - 871. [Abstract] [Full Text] [PDF] |
||||