Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print August 27, 2003, 10.1148/radiol.2291021151
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2291021151v1
229/1/99    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Taylor, S. A.
Right arrow Articles by Bartram, C. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Taylor, S. A.
Right arrow Articles by Bartram, C. I.
(Radiology 2003;229:99-108.)
© RSNA, 2003


Gastrointestinal Imaging

Optimizing Colonic Distention for Multi–Detector Row CT Colonography: Effect of Hyoscine Butylbromide and Rectal Balloon Catheter1

Stuart A. Taylor, BSc, MRCP, FRCR, Steve Halligan, MD, MRCP, FRCR, Vicky Goh, MRCP, FRCR, Simon Morley, MRCP, Paul Bassett, BSc, Wendy Atkin, PhD and Clive I. Bartram, FRCP, FRCS, FRCR

1 From the Intestinal Imaging Centre (S.A.T., S.H., V.G., S.M., P.B., C.I.B.) and Cancer Research UK Colorectal Cancer Unit (S.H., W.A.), Level 4V, St Mark’s Hospital, Watford Rd, Northwick Park, Harrow, Middlesex HA1 3UJ, England. Received September 20, 2002; revision requested November 26; final revision received February 5, 2003; accepted March 10. S.A.T. supported by a research fellowship from the Royal College of Radiologists and by GE Medical Systems, Slough, England. Address correspondence to S.H. (e-mail: s.halligan@ic.ac.uk).

PURPOSE: To investigate the effects of hyoscine butylbromide and an inflatable rectal balloon catheter on luminal distention during computed tomographic (CT) colonography.

MATERIALS AND METHODS: One hundred thirty-six subjects undergoing CT colonography were randomized to receive either 20 mg or 40 mg of hyoscine butylbromide or no spasmolytic. Subjects were also independently randomized to undergo CT colonography with an inflatable rectal balloon catheter or a standard thin rectal tube. Multi–detector row CT colonography was performed with patients in prone and supine positions, with colonic segmental distention assessed by a single observer with a four-point scale. A simple assessment of whether distention was adequate for clinical interpretation was also made, and the effect of hyoscine butylbromide and catheter use was examined by using multivariate ordered logistic regression.

RESULTS: Administration of hyoscine butylbromide was associated with significantly improved cecal (P = .05), ascending (P = .001), and transverse (P < .001) colonic distention when patients were supine and improved ascending (P < .001) and descending (P < .001) colonic distention when patients were prone. Compared with control subjects, patients given a spasmolytic had odds of 6.49 for clinically adequate distention throughout all colonic segments (P = .001). There was no incremental advantage with use of a 40-mg dose. In contrast, rectal balloon catheter use was not significantly associated with improved distention.

CONCLUSION: Hyoscine butylbromide improves colonic distention during CT colonography and should be routinely administered where it is available. Use of a thin rectal tube for insufflation is adequate.

© RSNA, 2003

Index terms: Catheters and catheterization • Colon, CT, 758.1211




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
J. Sosna, J. Bar-Ziv, E. Libson, M. Eligulashvili, and A. Blachar
CT Colonography: Positioning Order and Intracolonic Pressure
Am. J. Roentgenol., October 1, 2008; 191(4): W175 - W180.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. H. Park, S. S. Lee, J. K. Kim, M.-J. Kim, H. J. Kim, S. Y. Kim, M.-Y. Kim, A. Y. Kim, and H. K. Ha
Volume Rendering with Color Coding of Tagged Stool during Endoluminal Fly-through CT Colonography: Effect on Reading Efficiency
Radiology, September 1, 2008; 248(3): 1018 - 1027.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Y. Kim, S. H. Park, E. K. Choi, S. S. Lee, K. H. Lee, J. C. Kim, C. S. Yu, H. C. Kim, A. Y. Kim, and H. K. Ha
Automated Carbon Dioxide Insufflation for CT Colonography: Effectiveness of Colonic Distention in Cancer Patients with Severe Luminal Narrowing
Am. J. Roentgenol., March 1, 2008; 190(3): 698 - 706.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. K. Deshpande, R. M. Summers, R. L. Van Uitert, M. Franaszek, L. Brown, A. J. Dwyer, J. G. Fletcher, J. R. Choi, and P. J. Pickhardt
Quality Assessment for CT Colonography: Validation of Automated Measurement of Colonic Distention and Residual Fluid
Am. J. Roentgenol., December 1, 2007; 189(6): 1457 - 1463.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Halligan and D. G. Altman
Evidence-based Practice in Radiology: Steps 3 and 4--Appraise and Apply Systematic Reviews and Meta-Analyses
Radiology, April 1, 2007; 243(1): 13 - 27.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Jensch, R. E. van Gelder, J. Florie, M. A. T.-d. Graaf, J. V. Lobe, P. M. M. Bossuyt, S. Bipat, C. Y. Nio, and J. Stoker
Performance of Radiographers in the Evaluation of CT Colonographic Images
Am. J. Roentgenol., March 1, 2007; 188(3): W249 - W255.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
T. Mang, A. Maier, C. Plank, C. Mueller-Mang, C. Herold, and W. Schima
Pitfalls in Multi-Detector Row CT Colonography: A Systematic Approach
RadioGraphics, March 1, 2007; 27(2): 431 - 454.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
P. Veit-Haibach, C. A. Kuehle, T. Beyer, H. Stergar, H. Kuehl, J. Schmidt, G. Borsch, G. Dahmen, J. Barkhausen, A. Bockisch, et al.
Diagnostic Accuracy of Colorectal Cancer Staging With Whole-Body PET/CT Colonography
JAMA, December 6, 2006; 296(21): 2590 - 2600.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
A SLATER
Alteration in bowel habit
Imaging, December 1, 2006; 18(4): 208 - 217.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. J. Shinners, P. J. Pickhardt, A. J. Taylor, D. A. Jones, and C. H. Olsen
Patient-controlled room air insufflation versus automated carbon dioxide delivery for CT colonography.
Am. J. Roentgenol., June 1, 2006; 186(6): 1491 - 1496.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Burling, S. Halligan, A. Slater, M. J. Noakes, and S. A. Taylor
Potentially Serious Adverse Events at CT Colonography in Symptomatic Patients: National Survey of the United Kingdom
Radiology, May 1, 2006; 239(2): 464 - 471.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S A Taylor, S Halligan, A Slater, D Burling, M Marshall, and C I Bartram
Comparison of Radiologists' confidence in excluding significant colorectal neoplasia with multidetector-row CT colonography compared with double contrast barium enema.
Br. J. Radiol., March 1, 2006; 79(939): 208 - 214.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
P Veit, C Kuhle, T Beyer, H Kuehl, C U Herborn, G Borsch, H Stergar, J Barkhausen, A Bockisch, and G Antoch
Whole body positron emission tomography/computed tomography (PET/CT) tumour staging with integrated PET/CT colonography: technical feasibility and first experiences in patients with colorectal cancer
Gut, January 1, 2006; 55(1): 68 - 73.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Burling, S. A. Taylor, S. Halligan, L. Gartner, M. Paliwalla, C. Peiris, L. Singh, P. Bassett, and C. Bartram
Automated Insufflation of Carbon Dioxide for MDCT Colonography: Distension and Patient Experience Compared with Manual Insufflation
Am. J. Roentgenol., January 1, 2006; 186(1): 96 - 103.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Macari and E. J. Bini
CT Colonography: Where Have We Been and Where Are We Going?
Radiology, December 1, 2005; 237(3): 819 - 833.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Lefere, S. Gryspeerdt, J. Marrannes, M. Baekelandt, and B. Van Holsbeeck
CT Colonography After Fecal Tagging with a Reduced Cathartic Cleansing and a Reduced Volume of Barium
Am. J. Roentgenol., June 1, 2005; 184(6): 1836 - 1842.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. J. Chung, K. C. Huh, W. J. Choi, and J. K. Kim
CT Colonography Using 16-MDCT in the Evaluation of Colorectal Cancer
Am. J. Roentgenol., January 1, 2005; 184(1): 98 - 103.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. E. van Gelder, E. Birnie, J. Florie, M. P. Schutter, J. F. Bartelsman, P. Snel, J. S. Lameris, G. J. Bonsel, and J. Stoker
CT Colonography and Colonoscopy: Assessment of Patient Preference in a 5-week Follow-up Study
Radiology, November 1, 2004; 233(2): 328 - 337.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Lefere, S. Gryspeerdt, M. Baekelandt, and B. Van Holsbeeck
Laxative-Free CT Colonography
Am. J. Roentgenol., October 1, 2004; 183(4): 945 - 948.
[Full Text] [PDF]


Home page
RadiologyHome page
J. F. Bruzzi, H. M. Fenlon, S. Halligan, S. Taylor, P. Bassett, and C. Bartram
Colonic Distention in Multi-Detector Row CT Colonography [letter] * Dr Halligan and colleagues respond:
Radiology, April 1, 2004; 231(1): 282 - 283.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2003 by the Radiological Society of North America.