Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print September 25, 2003, 10.1148/radiol.2292020978
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2292020978v1
229/2/447    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burdío, F.
Right arrow Articles by Lozano, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burdío, F.
Right arrow Articles by Lozano, R.
(Radiology 2003;229:447-456.)
© RSNA, 2003


Experimental Studies

Bipolar Saline-enhanced Electrode for Radiofrequency Ablation: Results of Experimental Study of in Vivo Porcine Liver1

Fernando Burdío, MD, Antonio Güemes, MD, José M. Burdío, PhD, Ana Navarro, MD, Ramón Sousa, MD, Tomás Castiella, MD, Ignacio Cruz, MD, Olga Burzaco, MD and Ricardo Lozano, MD

1 From the Departments of Surgery A (F.B., A.G., A.N., R.S., R.L.) and Pathology (T.C.), Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain; and Departments of Electric Engineering and Communications (J.M.B.) and Animal Pathology and Surgery, Veterinary Faculty (I.C., O.B.), University of Zaragoza, Spain. Received August 5, 2002; revision requested September 24; final revision received February 26, 2003; accepted March 11. Supported by Spanish Government grant FIS 00/255 for medical research. Address correspondence to F.B., Tapis 155, 17600 Figueres (Girona), Spain (e-mail: fburdio@comll.es).

PURPOSE: To evaluate whether a bipolar saline-enhanced radiofrequency (RF) ablation system embedded in one needle is able to consistently produce homogeneous and predictable areas of coagulation necrosis with or without the Pringle maneuver of vascular inflow occlusion.

MATERIALS AND METHODS: RF ablation (480 kHz) of the liver was performed in 24 healthy pigs by means of laparotomy: group A (n = 5), 4-cm distance between electrodes 1 and 2; group B (n = 7), 4-cm distance and the Pringle maneuver; group C (n = 5), 2-cm distance; and group D (n = 7), 2-cm distance with the Pringle maneuver. Twenty percent NaCl solution was infused continuously at a rate of 100 mL/h via each electrode during the procedure. The pigs were followed up, and they were euthanized on the 7th day. Livers were removed for histologic assessment. Time, impedance, current, power output, specific voltage of the contacts, energy output, temperatures in the liver, volume of the lesion, and energy delivered per lesion volume were determined and compared among groups. Predictability of lesion volume was evaluated with the coefficient of variability. Mean values of the variables were compared among the groups by means of one-way analysis of variance or Kruskall-Wallis test.

RESULTS: Impedance at the end of the RF ablation procedure was almost twofold lower than the corresponding initial value in all groups. In Pringle groups B and D, regular ellipsoids of coagulation necrosis were created (mean lesion volume, 149.50 cm3 ± 34.26 and 69.43 cm3 ± 15.48, respectively). In non-Pringle groups A and C, the shape of coagulation necrosis was influenced by the vessels encountered, and mean lesion size was lower than that in the Pringle groups (P < .01). The coefficient of variability of lesion size was lower in the Pringle groups (23% and 22%, respectively) than that in the non-Pringle groups (75% and 30%, respectively).

CONCLUSION: The bipolar saline-enhanced RF ablation method produces homogeneous and predictable areas of coagulation necrosis between two electrodes, regardless of the distance between them, preferably with vascular inflow occlusion.

© RSNA, 2003

Index terms: Animals • Experimental study • Liver, interventional procedures, 761.1269 • Liver neoplasms, 761.1269 • Radiofrequency (RF) ablation, 761.1269




This article has been cited by other articles:


Home page
Ann. Surg. Oncol.Home page
S. Mulier, Y. Ni, L. Frich, F. Burdio, A. L. Denys, J.-F. De Wispelaere, B. Dupas, N. Habib, M. Hoey, M. C. Jansen, et al.
Experimental and Clinical Radiofrequency Ablation: Proposal for Standardized Description of Coagulation Size and Geometry
Ann. Surg. Oncol., April 1, 2007; 14(4): 1381 - 1396.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Clasen, D. Schmidt, A. Boss, K. Dietz, S. M. Krober, C. D. Claussen, and P. L. Pereira
Multipolar Radiofrequency Ablation with Internally Cooled Electrodes: Experimental Study in ex Vivo Bovine Liver with Mathematic Modeling
Radiology, March 1, 2006; 238(3): 881 - 890.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. M. Lee, J. K. Han, S. H. Kim, S. H. Choi, S. K. An, C. J. Han, and B. I. Choi
Bipolar Radiofrequency Ablation Using Wet-Cooled Electrodes: An In Vitro Experimental Study in Bovine Liver
Am. J. Roentgenol., February 1, 2005; 184(2): 391 - 397.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J M Lee, J K Han, S H Kim, J Y Lee, S H Choi, and B I Choi
Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes: a comparative study in the ex vivo bovine liver
Br. J. Radiol., November 1, 2004; 77(923): 944 - 949.
[Abstract] [Full Text] [PDF]