|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
How I Do It |
1 From the Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110. Received August 8, 2002; revision requested October 8; revision received November 20; accepted January 2, 2003; updated September 15. Address correspondence to the author (e-mail: siegelm@mir.wustl.edu).
Multidetector row computed tomography (CT) has changed the approach to imaging of thoracic anatomy and disease in the pediatric population. At the authors institution, multidetector row CT with multiplanar and three-dimensional reconstruction has become an important examination in the evaluation of systemic and pulmonary vasculature and the tracheobronchial tree. In some clinical situations, multidetector row CT with reformatted images is obviating conventional angiography, which is associated with higher radiation doses and longer sedation times. Although multidetector row CT with multiplanar and three-dimensional reconstruction is expanding the applications of CT of the thorax, its role as a diagnostic tool still needs to be better defined. The purposes of this article are to describe how to perform multidetector row CT with multiplanar and three-dimensional reconstruction in young patients, to discuss various reconstruction techniques available, and to discuss applications in the evaluation of vascular and airways diseases.
© RSNA, 2003
Index terms: Aorta, CT, 56.12111, 56.12112, 56.12117 Bronchi, CT, 671.12111, 671.12117 Computed tomography (CT), in infants and children Computed tomography (CT), multidetector row, **.121172 Radiology and radiologists, How I Do It Trachea, CT, 671.12111, 671.12117
This article has been cited by other articles:
![]() |
E. Y. Lee and P. M. Boiselle Tracheobronchomalacia in Infants and Children: Multidetector CT Evaluation Radiology, July 1, 2009; 252(1): 7 - 22. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Dillman and R. J. Hernandez Role of CT in the Evaluation of Congenital Cardiovascular Disease in Children Am. J. Roentgenol., May 1, 2009; 192(5): 1219 - 1231. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Y. Lee, P. M. Boiselle, and R. H. Cleveland Multidetector CT Evaluation of Congenital Lung Anomalies Radiology, June 1, 2008; 247(3): 632 - 648. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Eichhorn, C. Jourdan, S. L. Hill, S. V. Raman, J. P. Cheatham, and F. R. Long CT of Pediatric Vascular Stents Used to Treat Congenital Heart Disease Am. J. Roentgenol., May 1, 2008; 190(5): 1241 - 1246. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Honnef, J. E. Wildberger, G. Haras, C. Hohl, G. Staatz, R. W. Gunther, and A. H. Mahnken Prospective Evaluation of Image Quality with Use of a Patient Image Gallery for Dose Reduction in Pediatric 16-MDCT Am. J. Roentgenol., February 1, 2008; 190(2): 467 - 473. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Long High-Resolution Computed Tomography of the Lung in Children with Cystic Fibrosis: Technical Factors Proceedings of the ATS, August 1, 2007; 4(4): 306 - 309. [Abstract] [Full Text] [PDF] |
||||
![]() |
B Oguz, M Haliloglu, and M Karcaaltincaba Paediatric multidetector CT angiography: spectrum of congenital thoracic vascular anomalies Br. J. Radiol., May 1, 2007; 80(953): 376 - 383. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z A Aziz, J C Davies, E W Alton, A U Wells, D M Geddes, and D M Hansell Computed tomography and cystic fibrosis: promises and problems Thorax, February 1, 2007; 62(2): 181 - 186. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Heyer, T. G. Nuesslein, D. Jung, S. A. Peters, S. P. Lemburg, C. H. L. Rieger, and V. Nicolas Tracheobronchial Anomalies and Stenoses: Detection with Low-Dose Multidetector CT with Virtual Tracheobronchoscopy--Comparison with Flexible Tracheobronchoscopy Radiology, February 1, 2007; 242(2): 542 - 549. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. M. Chan, W. C. W. Chu, K. L. Cheung, A. A. Arifi, and W. W. M. Lam Angiography and Dynamic Airway Evaluation with MDCT in the Diagnosis of Double Aortic Arch Associated with Tracheomalacia Am. J. Roentgenol., November 1, 2005; 185(5): 1248 - 1251. [Full Text] [PDF] |
||||
![]() |
M. J. Siegel, B. Schmidt, D. Bradley, C. Suess, and C. Hildebolt Radiation Dose and Image Quality in Pediatric CT: Effect of Technical Factors and Phantom Size and Shape Radiology, November 1, 2004; 233(2): 515 - 522. [Abstract] [Full Text] [PDF] |
||||