|
|
||||||||
Technical Developments |
1 From the Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn, Germany (W.A.W., M.B., B.S., H. J. Tschampa, C.K., H.U., H. J. Textor, H.H.S.); and Philips Medical Systems, Best, the Netherlands (J.G.). Received June 27, 2002; revision requested August 23; final revision received March 15, 2003; accepted March 20. Address correspondence to W.A.W. (e-mail: willinek@uni-bonn.de).
Intracranial three-dimensional time-of-flight (TOF) magnetic resonance (MR) angiography was performed in seven healthy volunteers and eight patients with both 1.5-T and 3.0-T MR systems with standard and high spatial resolutions (true voxel sizes, 0.48 x 0.75 x 2.00 mm and 0.30 x 0.44 x 1.00 mm, respectively). Superior image quality and significantly better depiction of small vessel segments and vascular disease were observed at high-spatial-resolution 3.0-T TOF MR angiography but not at standard 1.5-T or standard 3.0-T TOF MR angiography (P < .01, respectively). Intracranial high-spatial-resolution TOF MR angiography at 3.0-T imaging provides diagnostic improvement in studies of cerebrovascular disease.
© RSNA, 2003
Index terms: Brain, MR, 17.12142 Magnetic resonance (MR), vascular studies, 17.12142
This article has been cited by other articles:
![]() |
A. Tomasian, N. Salamon, D. G. Lohan, M. Jalili, J. P. Villablanca, and J. P. Finn Supraaortic Arteries: Contrast Material Dose Reduction at 3.0-T High-Spatial-Resolution MR Angiography--Feasibility Study Radiology, December 1, 2008; 249(3): 980 - 990. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. P. Naehle, C. Meyer, D. Thomas, S. Remerie, C. Krautmacher, H. Litt, R. Luechinger, R. Fimmers, H. Schild, and T. Sommer Safety of Brain 3-T MR Imaging with Transmit-Receive Head Coil in Patients with Cardiac Pacemakers: Pilot Prospective Study with 51 Examinations Radiology, December 1, 2008; 249(3): 991 - 1001. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Chang, I. R. Kamel, K. J. Macura, and D. A. Bluemke 3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T RadioGraphics, November 1, 2008; 28(7): 1983 - 1998. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Anzalone, F. Scomazzoni, M. Cirillo, C. Righi, F. Simionato, M. Cadioli, A. Iadanza, M.A. Kirchin, and G. Scotti Follow-Up of Coiled Cerebral Aneurysms at 3T: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography AJNR Am. J. Neuroradiol., September 1, 2008; 29(8): 1530 - 1536. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Habibi, M. S. Krishnam, D. G. Lohan, F. Barkhordarian, M. Jalili, R. S. Saleh, S. G. Ruehm, and J. P. Finn High-Spatial-Resolution Lower Extremity MR Angiography at 3.0 T: Contrast Agent Dose Comparison Study Radiology, August 1, 2008; 248(2): 680 - 692. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Wang, V. L. Yarnykh, J. A. Molitor, R. A. Nash, B. Chu, G. J. Wilson, J. Fleming, S. M. Schwartz, and C. Yuan Micro magnetic resonance angiography of the finger in systemic sclerosis Rheumatology, August 1, 2008; 47(8): 1239 - 1243. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Nelles, J. Gieseke, S. Flacke, L. Lachenmayer, H.H. Schild, and H. Urbach Diffusion Tensor Pyramidal Tractography in Patients With Anterior Choroidal Artery Infarcts AJNR Am. J. Neuroradiol., March 1, 2008; 29(3): 488 - 493. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. K. Kuhl, F. Traber, and H. H. Schild Whole-Body High-Field-Strength (3.0-T) MR Imaging in Clinical Practice * Part I. Technical Considerations and Clinical Applications Radiology, March 1, 2008; 246(3): 675 - 696. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Y. Kim, C. A Yi, K. S. Lee, M. J. Chung, Y. K. Kim, B. K. Choi, H. Kim, and O J. Kwon Nodal Metastasis in Non Small Cell Lung Cancer: Accuracy of 3.0-T MR Imaging Radiology, December 4, 2007; (2007) 2461061907. [Abstract] [Full Text] |
||||
![]() |
C.G. Choi, D.H. Lee, J.H. Lee, H.W. Pyun, D.W. Kang, S.U. Kwon, J.K. Kim, S.J. Kim, and D.C. Suh Detection of Intracranial Atherosclerotic Steno-Occlusive Disease with 3D Time-of-Flight Magnetic Resonance Angiography with Sensitivity Encoding at 3T AJNR Am. J. Neuroradiol., March 1, 2007; 28(3): 439 - 446. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nael, M. Fenchel, M. Krishnam, G. Laub, J. P. Finn, and S. G. Ruehm High-Spatial-Resolution Whole-Body MR Angiography with High-Acceleration Parallel Acquisition and 32-Channel 3.0-T Unit: Initial Experience Radiology, March 1, 2007; 242(3): 865 - 872. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nael, J. P. Villablanca, W. B. Pope, T. O. McNamara, G. Laub, and J. P. Finn Supraaortic Arteries: Contrast-enhanced MR Angiography at 3.0 T--Highly Accelerated Parallel Acquisition for Improved Spatial Resolution over an Extended Field of View Radiology, February 1, 2007; 242(2): 600 - 609. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Morakkabati-Spitz, H. H. Schild, C. K. Kuhl, G. Lutterbey, M. von Falkenhausen, F. Traber, and J. Gieseke Female Pelvis: MR Imaging at 3.0 T with Sensitivity Encoding and Flip-Angle Sweep Technique Radiology, November 1, 2006; 241(2): 538 - 545. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. von Falkenhausen, G. Lutterbey, N. Morakkabati-Spitz, O. Walter, J. Gieseke, R. Blomer, W. A. Willinek, H. H. Schild, and C. K. Kuhl High-Field-Strength MR Imaging of the Liver at 3.0 T: Intraindividual Comparative Study with MR Imaging at 1.5 T Radiology, October 1, 2006; 241(1): 156 - 166. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nael, H. J. Michaely, U. Kramer, M. H. Lee, J. Goldin, G. Laub, and J. P. Finn Pulmonary Circulation: Contrast-enhanced 3.0-T MR Angiography--Initial Results Radiology, September 1, 2006; 240(3): 858 - 868. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nael, R. Saleh, M. Lee, T. McNamara, S. R. Godinez, G. Laub, J. P. Finn, and S. G. Ruehm High-spatial-resolution contrast-enhanced MR angiography of abdominal arteries with parallel acquisition at 3.0 T: initial experience in 32 patients. Am. J. Roentgenol., July 1, 2006; 187(1): W77 - W85. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Fushimi, Y. Miki, K.-i. Kikuta, T. Okada, M. Kanagaki, A. Yamamoto, K. Nozaki, N. Hashimoto, T. Hanakawa, H. Fukuyama, et al. Comparison of 3.0- and 1.5-T Three-dimensional Time-of-Flight MR Angiography in Moyamoya Disease: Preliminary Experience Radiology, April 1, 2006; 239(1): 232 - 237. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Okada, Y. Miki, Y. Fushimi, T. Hanakawa, M. Kanagaki, A. Yamamoto, S.-i. Urayama, H. Fukuyama, M. Hiraoka, and K. Togashi Diffusion-Tensor Fiber Tractography: Intraindividual Comparison of 3.0-T and 1.5-T MR Imaging Radiology, February 1, 2006; 238(2): 668 - 678. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L. Schmitz, A. J. Aschoff, M. H.K. Hoffmann, and G. Gron Advantages and Pitfalls in 3T MR Brain Imaging: A Pictorial Review AJNR Am. J. Neuroradiol., October 1, 2005; 26(9): 2229 - 2237. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |