|
|
||||||||
Technical Developments |
1 From the Department of Diagnostic and Interventional Radiology, University Hospital Essen, Hufelandstrasse 55, 45122 Essen, Germany. Received November 21, 2002; revision requested January 21, 2003; final revision received June 10; accepted July 8. Address correspondence to C.U.H. (e-mail: christoph.herborn@uni-essen.de).
Five volunteers and 10 patients suspected of having peripheral vascular disease underwent multistation contrast materialenhanced three-dimensional whole-body magnetic resonance (MR) angiography. The first examination, based on standard protocol, lasted 72 seconds, while the following two examinations, performed with a high-spatial-resolution T1-weighted gradient-recalled-echo sequence for the last two stations (lower extremities) lasted 170 seconds. In the second high-resolution examination, midfemoral venous compression was used. Intraindividual comparison showed the high-resolution protocol with venous compression resulted in the best qualitative and quantitative image quality through higher signal-to-noise and contrast-to-noise ratios in the calf arteries. Despite prolonged acquisition times, there was no venous contamination. The data suggest that midfemoral venous compression should be incorporated in multistation protocols of the lower extremities to improve depiction of calf arteries without disturbing venous overlap.
© RSNA, 2004
Index terms: Arteries, extremities Arteries, MR, 90.129412, 90.12942, 90.12943 Arteries, stenosis or obstruction, 90.721 Magnetic resonance (MR), high resolution Magnetic resonance (MR), vascular studies, 90.129412, 90.12942, 90.12943 Veins, femoral
This article has been cited by other articles:
![]() |
K. Lin, Z.-Q. Zhang, J.-Y. Sun, Z.-M. Fan, and B. Lu Low Injection Rate for 3D Moving-Table Bolus-Chase MR Angiography: Initial Experience with 3-T Imaging to Allay Venous Contamination in the Calf Am. J. Roentgenol., December 1, 2008; 191(6): 1734 - 1739. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. R. Hadizadeh, J. Gieseke, S. H. Lohmaier, K. Wilhelm, J. Boschewitz, F. Verrel, H. H. Schild, and W. A. Willinek Peripheral MR Angiography with Blood Pool Contrast Agent: Prospective Intraindividual Comparative Study of High-Spatial-Resolution Steady-State MR Angiography versus Standard-Resolution First-Pass MR Angiography and DSA Radiology, November 1, 2008; 249(2): 701 - 711. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nael, S. G. Ruehm, H. J. Michaely, R. Saleh, M. Lee, G. Laub, and J. P. Finn Multistation Whole-Body High-Spatial-Resolution MR Angiography Using a 32-Channel MR System Am. J. Roentgenol., February 1, 2007; 188(2): 529 - 539. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Gluecker, G. Bongartz, H. P. Ledermann, and D. Bilecen MR Angiography of the Hand with Subsystolic Cuff-Compression Optimization of Injection Parameters Am. J. Roentgenol., October 1, 2006; 187(4): 905 - 910. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. S. Pereles, J. D. Collins, J. C. Carr, C. Francois, M. D. Morasch, R. M. McCarthy, E. A. Krupinski, G. M. Butler, and J. P. Finn Accuracy of Stepping-Table Lower Extremity MR Angiography with Dual-Level Bolus Timing and Separate Calf Acquisition: Hybrid Peripheral MR Angiography Radiology, July 1, 2006; 240(1): 283 - 290. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. L. Zhang, N. M. Khilnani, M. R. Prince, P. A. Winchester, P. Golia, P. Veit, R. Watts, and Y. Wang Diagnostic Accuracy of Time-Resolved 2D Projection MR Angiography for Symptomatic Infrapopliteal Arterial Occlusive Disease Am. J. Roentgenol., March 1, 2005; 184(3): 938 - 947. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Bilecen, A. C. Schulte, M. Aschwanden, K. Jaeger, G. Bongartz, C. U. Herborn, and J. F. Debatin MR Angiography with Venous Compression * Drs Herborn and Debatin respond: Radiology, November 1, 2004; 233(2): 617 - 619. [Full Text] [PDF] |
||||