Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2303021527
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Herborn, C. U.
Right arrow Articles by Debatin, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Herborn, C. U.
Right arrow Articles by Debatin, J. F.
(Radiology 2004;230:872-878.)
© RSNA, 2004


Technical Developments

Peripheral Vasculature: Whole-Body MR Angiography with Midfemoral Venous Compression—Initial Experience1

Christoph U. Herborn, MD, Waleed Ajaj, MD, Mathias Goyen, MD, Sandra Massing, RT, Stefan G. Ruehm, MD and Jörg F. Debatin, MD, MBA

1 From the Department of Diagnostic and Interventional Radiology, University Hospital Essen, Hufelandstrasse 55, 45122 Essen, Germany. Received November 21, 2002; revision requested January 21, 2003; final revision received June 10; accepted July 8. Address correspondence to C.U.H. (e-mail: christoph.herborn@uni-essen.de).

Five volunteers and 10 patients suspected of having peripheral vascular disease underwent multistation contrast material–enhanced three-dimensional whole-body magnetic resonance (MR) angiography. The first examination, based on standard protocol, lasted 72 seconds, while the following two examinations, performed with a high-spatial-resolution T1-weighted gradient-recalled-echo sequence for the last two stations (lower extremities) lasted 170 seconds. In the second high-resolution examination, midfemoral venous compression was used. Intraindividual comparison showed the high-resolution protocol with venous compression resulted in the best qualitative and quantitative image quality through higher signal-to-noise and contrast-to-noise ratios in the calf arteries. Despite prolonged acquisition times, there was no venous contamination. The data suggest that midfemoral venous compression should be incorporated in multistation protocols of the lower extremities to improve depiction of calf arteries without disturbing venous overlap.

© RSNA, 2004

Index terms: Arteries, extremities • Arteries, MR, 90.129412, 90.12942, 90.12943 • Arteries, stenosis or obstruction, 90.721 • Magnetic resonance (MR), high resolution • Magnetic resonance (MR), vascular studies, 90.129412, 90.12942, 90.12943 • Veins, femoral




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. Lin, Z.-Q. Zhang, J.-Y. Sun, Z.-M. Fan, and B. Lu
Low Injection Rate for 3D Moving-Table Bolus-Chase MR Angiography: Initial Experience with 3-T Imaging to Allay Venous Contamination in the Calf
Am. J. Roentgenol., December 1, 2008; 191(6): 1734 - 1739.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. R. Hadizadeh, J. Gieseke, S. H. Lohmaier, K. Wilhelm, J. Boschewitz, F. Verrel, H. H. Schild, and W. A. Willinek
Peripheral MR Angiography with Blood Pool Contrast Agent: Prospective Intraindividual Comparative Study of High-Spatial-Resolution Steady-State MR Angiography versus Standard-Resolution First-Pass MR Angiography and DSA
Radiology, November 1, 2008; 249(2): 701 - 711.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Nael, S. G. Ruehm, H. J. Michaely, R. Saleh, M. Lee, G. Laub, and J. P. Finn
Multistation Whole-Body High-Spatial-Resolution MR Angiography Using a 32-Channel MR System
Am. J. Roentgenol., February 1, 2007; 188(2): 529 - 539.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. M. Gluecker, G. Bongartz, H. P. Ledermann, and D. Bilecen
MR Angiography of the Hand with Subsystolic Cuff-Compression Optimization of Injection Parameters
Am. J. Roentgenol., October 1, 2006; 187(4): 905 - 910.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. S. Pereles, J. D. Collins, J. C. Carr, C. Francois, M. D. Morasch, R. M. McCarthy, E. A. Krupinski, G. M. Butler, and J. P. Finn
Accuracy of Stepping-Table Lower Extremity MR Angiography with Dual-Level Bolus Timing and Separate Calf Acquisition: Hybrid Peripheral MR Angiography
Radiology, July 1, 2006; 240(1): 283 - 290.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. L. Zhang, N. M. Khilnani, M. R. Prince, P. A. Winchester, P. Golia, P. Veit, R. Watts, and Y. Wang
Diagnostic Accuracy of Time-Resolved 2D Projection MR Angiography for Symptomatic Infrapopliteal Arterial Occlusive Disease
Am. J. Roentgenol., March 1, 2005; 184(3): 938 - 947.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Bilecen, A. C. Schulte, M. Aschwanden, K. Jaeger, G. Bongartz, C. U. Herborn, and J. F. Debatin
MR Angiography with Venous Compression * Drs Herborn and Debatin respond:
Radiology, November 1, 2004; 233(2): 617 - 619.
[Full Text] [PDF]