Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2312030553
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kostis, W. J.
Right arrow Articles by Henschke, C. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kostis, W. J.
Right arrow Articles by Henschke, C. I.
(Radiology 2004;231:446-452.)
© RSNA, 2004


Thoracic Imaging

Small Pulmonary Nodules: Reproducibility of Three-dimensional Volumetric Measurement and Estimation of Time to Follow-up CT1

William J. Kostis, PhD, David F. Yankelevitz, MD, Anthony P. Reeves, PhD, Simina C. Fluture, MS and Claudia I. Henschke, PhD, MD

1 From the Department of Radiology, Weill Medical College of Cornell University, 525 E 68th St, New York, NY 10021 (W.J.K., D.F.Y., S.C.F., C.I.H.); and School of Electrical and Computer Engineering, Cornell University, Ithaca, NY (A.P.R.). Received April 8, 2003; revision requested June 20; revision received August 17; accepted September 29. Supported in part by National Institutes of Health grant R01-CA78905. Address correspondence to C.I.H. (e-mail: chensch@med.cornell.edu).

PURPOSE: To determine reproducibility of volume measurements of small pulmonary nodules on computed tomographic (CT) scans and to estimate critical time to follow-up CT.

MATERIALS AND METHODS: One hundred fifteen pulmonary nodules for which two thin-section small–field-of-view CT scans were obtained and which were stable during 2-year observation were evaluated. A standard group of 94 nodules (with no or minimal artifact) and an expanded group of 105 nodules (including those with moderate artifacts) were examined. Percentage volume change (PVC) and monthly volumetric growth index (MVGI) were computed for each nodule pair. By using estimates of the variation in PVC in stable nodules as a function of initial diameter, critical time to follow-up CT was estimated; this time is the earliest point at which growth in a nodule of a given size can be reliably identified with repeat CT.

RESULTS: The SD of PVC decreased with increasing nodule size from 18.5% in 2–5-mm nodules to 10.6% in 5–8-mm nodules and to 7.47% in 8–10-mm nodules. Inclusion of cases with moderate motion artifacts increased the SD of PVC to 27.4% in 2–5-mm nodules, to 17.1% in 5–8-mm nodules, and to 19.3% in 8–10-mm nodules. Critical time to follow-up CT for nodules detected at baseline screening was 12, 5, and 3 months and 1 month for those with initial sizes of 2, 5, 8, and 10 mm, respectively. For nodules detected at annual repeat screening, it was 4 and 3 months and 1 month for nodules that were 3, 4, and 5 mm or larger in size, respectively. Mean MVGI in 94 standard cases was 0.06%, and standard error was 0.21%.

CONCLUSION: Factors that affect reproducibility of nodule volume measurements and critical time to follow-up CT include nodule size at detection, type of scan (baseline or annual repeat) on which the nodule is detected, and presence of patient-induced artifacts.

© RSNA, 2004

Index terms: Cancer screening • Computed tomography (CT), artifact, 60.93 • Computed tomography (CT), thin-section, 60.12118 • Computed tomography (CT), three-dimensional, 60.12117 • Computed tomography (CT), volume rendering • Lung, nodule, 60.332 • Lung neoplasms, screening




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. Girvin and J. P. Ko
Pulmonary Nodules: Detection, Assessment, and CAD
Am. J. Roentgenol., October 1, 2008; 191(4): 1057 - 1069.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Wang, R. J. van Klaveren, H. J. van der Zaag-Loonen, G. H. de Bock, H. A. Gietema, D. M. Xu, A. L. M. Leusveld, H. J. de Koning, E. T. Scholten, J. Verschakelen, et al.
Effect of Nodule Characteristics on Variability of Semiautomated Volume Measurements in Pulmonary Nodules Detected in a Lung Cancer Screening Program
Radiology, August 1, 2008; 248(2): 625 - 631.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Jeudy, C. S. White, R. F. Munden, and P. M. Boiselle
Management of Small (3-5-mm) Pulmonary Nodules at Chest CT: Global Survey of Thoracic Radiologists
Radiology, June 1, 2008; 247(3): 847 - 853.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. G. Ravenel, W. M. Leue, P. J. Nietert, J. V. Miller, K. K. Taylor, and G. A. Silvestri
Pulmonary Nodule Volume: Effects of Reconstruction Parameters on Automated Measurements--A Phantom Study
Radiology, May 1, 2008; 247(2): 400 - 408.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
C. I. Henschke and D. F. Yankelevitz
CT Screening for Lung Cancer: Update 2007
Oncologist, January 1, 2008; 13(1): 65 - 78.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. A. Gietema, C. M. Schaefer-Prokop, W. P. T. M. Mali, G. Groenewegen, and M. Prokop
Pulmonary Nodules: Interscan Variability of Semiautomated Volume Measurements with Multisection CT Influence of Inspiration Level, Nodule Size, and Segmentation Performance
Radiology, December 1, 2007; 245(3): 888 - 894.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. S. Gierada, T. K. Pilgram, M. Ford, R. M. Fagerstrom, T. R. Church, H. Nath, K. Garg, and D. C. Strollo
Lung Cancer: Interobserver Agreement on Interpretation of Pulmonary Findings at Low-Dose CT Screening
Radiology, December 1, 2007; 246(1): 265 - 272.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
J. Aisner
CT Screening for Lung Cancer: Are We Ready for Wide-Scale Application?
Clin. Cancer Res., September 1, 2007; 13(17): 4951 - 4953.
[Full Text] [PDF]


Home page
RadiologyHome page
New York Early Lung Cancer Action Project Investig
CT Screening for Lung Cancer: Diagnoses Resulting from the New York Early Lung Cancer Action Project
Radiology, April 1, 2007; 243(1): 239 - 249.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Petrou, L. E. Quint, B. Nan, and L. H. Baker
Pulmonary Nodule Volumetric Measurement Variability as a Function of CT Slice Thickness and Nodule Morphology
Am. J. Roentgenol., February 1, 2007; 188(2): 306 - 312.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Jennings, H. T. Winer-Muram, M. Tann, J. Ying, and I. Dowdeswell
Distribution of Stage I Lung Cancer Growth Rates Determined with Serial Volumetric CT Measurements
Radiology, November 1, 2006; 241(2): 554 - 563.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
The International Early Lung Cancer Action Program
Survival of Patients with Stage I Lung Cancer Detected on CT Screening
N. Engl. J. Med., October 26, 2006; 355(17): 1763 - 1771.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. A. Gietema, Y. Wang, D. Xu, R. J. van Klaveren, H. de Koning, E. Scholten, J. Verschakelen, G. Kohl, M. Oudkerk, and M. Prokop
Pulmonary Nodules Detected at Lung Cancer Screening: Interobserver Variability of Semiautomated Volume Measurements
Radiology, October 1, 2006; 241(1): 251 - 257.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Plathow, M. Schoebinger, C. Fink, H. Hof, J. Debus, H.-P. Meinzer, and H.-U. Kauczor
Quantification of Lung Tumor Volume and Rotation at 3D Dynamic Parallel MR Imaging with View Sharing: Preliminary Results
Radiology, August 1, 2006; 240(2): 537 - 545.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. J. Pickhardt, V. T. Lehman, T. C. Winter, and A. J. Taylor
Polyp volume versus linear size measurements at CT colonography: implications for noninvasive surveillance of unresected colorectal lesions.
Am. J. Roentgenol., June 1, 2006; 186(6): 1605 - 1610.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Ko, R. Marcus, E. Bomsztyk, J. S. Babb, C. Stefanescu, M. Kaur, D. P. Naidich, and H. Rusinek
Effect of blood vessels on measurement of nodule volume in a chest phantom.
Radiology, April 1, 2006; 239(1): 79 - 85.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Awai, K. Murao, A. Ozawa, Y. Nakayama, T. Nakaura, D. Liu, K. Kawanaka, Y. Funama, S. Morishita, and Y. Yamashita
Pulmonary Nodules: Estimation of Malignancy at Thin-Section Helical CT--Effect of Computer-aided Diagnosis on Performance of Radiologists
Radiology, April 1, 2006; 239(1): 276 - 284.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. MacMahon, J. H. M. Austin, G. Gamsu, C. J. Herold, J. R. Jett, D. P. Naidich, E. F. Patz Jr, and S. J. Swensen
Guidelines for Management of Small Pulmonary Nodules Detected on CT Scans: A Statement from the Fleischner Society
Radiology, November 1, 2005; 237(2): 395 - 400.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Ko, J. Chang, E. Bomsztyk, J. S. Babb, D. P. Naidich, and H. Rusinek
Effect of CT Image Compression on Computer-assisted Lung Nodule Volume Measurement
Radiology, October 1, 2005; 237(1): 83 - 88.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
J. L. Mulshine
Clinical Issues in the Management of Early Lung Cancer
Clin. Cancer Res., July 1, 2005; 11(13): 4993s - 4998s.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.