Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print March 18, 2004, 10.1148/radiol.2312030594
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2312030594v1
231/2/491    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nijsen, J. F. W.
Right arrow Articles by van het Schip, A. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nijsen, J. F. W.
Right arrow Articles by van het Schip, A. D.
(Radiology 2004;231:491-499.)
© RSNA, 2004


Experimental Studies

Liver Tumors: MR Imaging of Radioactive Holmium Microspheres—Phantom and Rabbit Study1

Johannes F. W. Nijsen, PhD, Jan-Henry Seppenwoolde, MSc, Thomas Havenith, MSc, Clemens Bos, PhD, Chris J. G. Bakker, PhD and Alfred D. van het Schip, PhD

1 From the Department of Nuclear Medicine, University Medical Centre, Heidelberglaan 100, Room E02.222, 3584 CX, Utrecht, the Netherlands (J.F.W.N., T.H., A.D.v.h.S.); and Image Sciences Institute, University Medical Centre, Utrecht, the Netherlands (J.H.S., C.B., C.J.G.B.). Received April 15, 2003; revision requested July 1; revision received August 22; accepted October 8. Address correspondence to J.F.W.N. (e-mail: f.nijsen@azu.nl).

PURPOSE: To investigate the use of magnetic resonance (MR) imaging in the administration and biodistribution of holmium-loaded poly(L-lactic acid) microspheres (Ho-PLLA-MS) in liver tumors.

MATERIALS AND METHODS: MR imaging measurements were obtained in phantoms, three ex vivo rabbit livers, and four livers in living rabbits. When applicable, measurements were compared with those on scintigraphic images. The transverse relaxivity R2* of the Ho-PLLA-MS was determined in a phantom study. The in vivo animal experiments were performed by using rabbits with an implanted VX2 tumor. Detection of passing Ho-PLLA-MS to estimate lung shunting was performed in a scaled model of the vena cava.

RESULTS: In the ex vivo liver experiments, the feasibility of real-time MR imaging during administration of microspheres was demonstrated. The in vivo rabbit experiments demonstrated that MR imaging can depict radioactive, nonradioactive, and decayed Ho-PLLA-MS after treatment for as long as they remain in the body. Furthermore, this study showed the ability of dynamic MR imaging to detect single doses of passing Ho-PLLA-MS.

CONCLUSION: Ho-PLLA-MS used for internal radionuclide therapy can be imaged clearly in vivo with MR imaging.

© RSNA, 2004

Index terms: Animals • Liver neoplasms, therapy, 761.12166, 761.1264, 761.1269 • Magnetic resonance (MR), experimental studies • Microspheres • Phantoms




This article has been cited by other articles:


Home page
RadiologyHome page
T. Gupta, S. Virmani, T. M. Neidt, B. Szolc-Kowalska, K. T. Sato, R. K. Ryu, R. J. Lewandowski, V. L. Gates, G. E. Woloschak, R. Salem, et al.
MR Tracking of Iron-labeled Glass Radioembolization Microspheres during Transcatheter Delivery to Rabbit VX2 Liver Tumors: Feasibility Study
Radiology, December 1, 2008; 249(3): 845 - 854.