Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print May 20, 2004, 10.1148/radiol.2321030666
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2321030666v1
232/1/229    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Quigley, M. F.
Right arrow Articles by Haughton, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Quigley, M. F.
Right arrow Articles by Haughton, V.
(Radiology 2004;232:229-236.)
© RSNA, 2004


Neuroradiology

Cerebrospinal Fluid Flow in Foramen Magnum: Temporal and Spatial Patterns at MR Imaging in Volunteers and in Patients with Chiari I Malformation1

Mark F. Quigley, PhD, Bermans Iskandar, MD, Michelle A. Quigley, PhD, Mark Nicosia, PhD and Victor Haughton, MD

1 From the Departments of Radiology and Medical Physics, University of Wisconsin, 600 Highland Ave, Madison WI 53792. Received May 12, 2003; revision requested July 2; revision received October 10; accepted November 17. Address correspondence to V.H. (e-mail: vmhaughton@wisc.edu).

PURPOSE: To measure spatial and temporal variations in cerebrospinal fluid (CSF) flow through the cardiac cycle and throughout the subarachnoid space at magnetic resonance (MR) imaging in volunteer subjects with no known neurologic or spinal problems and in patients with Chiari I malformation.

MATERIALS AND METHODS: A cardiac-gated phase-contrast MR technique was used to acquire images at 14 time points evenly spaced through the cardiac cycle in 10 volunteers and eight patients with Chiari I malformation. Instantaneous CSF velocities were displayed as temporal and spatial plots and examined for homogeneity, differences between flow anterior and flow posterior to the spinal cord, synchronous bidirectional flow, and equivalence of the caudad flow and craniad flow in each voxel. Indexes for flow homogeneity, synchronous bidirectional flow, and preferential flow direction were calculated, and differences between the patient and volunteer groups were tested for significance with a t test of the means.

RESULTS: In volunteers, diastolic velocity peaked in two regions in the anterior paramedial subarachnoid space. Patients had greater inhomogeneity of flow than volunteers. They had substantially increased flow (jets) in the anterior paramedial locations. Synchronous bidirectional flow was seen in six of the patients and in none of the volunteers. Cephalad flow in the jets or nodes (P = .05), proportion of cephalad and caudad flow in the anterior compartment (P < .005 for both), and the fraction of voxels with flow directionality (P = .03) differed significantly between patients and volunteers.

CONCLUSION: CSF flow in symptomatic patients with Chiari I malformation, unlike that in volunteer subjects, is characterized by flow jets, regions with a preponderance of flow in one direction, and synchronous bidirectional flow.

© RSNA, 2004

Index terms: Brain, abnormalities, 152.1473, 1538.1473 • Brain, MR, 127.12144, 1532.12144 • Cerebrospinal fluid, flow dynamics, 167.12144 • Cerebrospinal fluid, MR, 167.12144




This article has been cited by other articles:


Home page
RadiologyHome page
S. K. Hofkes, B. J. Iskandar, P. A. Turski, L. R. Gentry, J. B. McCue, and V. M. Haughton
Differentiation between Symptomatic Chiari I Malformation and Asymptomatic Tonsilar Ectopia by Using Cerebrospinal Fluid Flow Imaging: Initial Estimate of Imaging Accuracy
Radiology, November 1, 2007; 245(2): 532 - 540.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Ley, C. Fink, M. Puderbach, J. Zaporozhan, C. Plathow, M. Eichinger, W. Hosch, K.-F. Kreitner, and H.-U. Kauczor
MRI Measurement of the hemodynamics of the pulmonary and systemic arterial circulation: influence of breathing maneuvers.