Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2322030184
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pereira, P. L.
Right arrow Articles by Claussen, C. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pereira, P. L.
Right arrow Articles by Claussen, C. D.
(Radiology 2004;232:482-490.)
© RSNA, 2004


Experimental Studies

Radiofrequency Ablation: In Vivo Comparison of Four Commercially Available Devices in Pig Livers1

Philippe L. Pereira, MD, Jochen Trübenbach, MD, Martin Schenk, PhD, Jörg Subke, MD, Stephan Kroeber, MD, Ines Schaefer, MD, Christopher T. Remy, MD, Diethard Schmidt, MD, Jens Brieger, PhD and Claus D. Claussen, MD

1 From the Department of Diagnostic Radiology (P.L.P., J.T., I.S., C.T.R., D.S., C.D.S.), Section of Experimental Radiology (J.B.), and Departments of General Surgery (M.S.), Forensic Medicine (J.S.), and Pathology (S.K.), Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076 Tübingen, Germany. From the 2002 RSNA scientific assembly. Received February 13, 2003; revision requested May 1; final revision received October 31; accepted January 2, 2004. Address correspondence to P.L.P. (e-mail: philippe.pereira@med.uni-tuebingen.de).

PURPOSE: To compare in vivo coagulation necrosis obtained with four radiofrequency (RF) ablation devices, to determine shape and reproducibility of induced coagulation by means of three-dimensional measurements of the ablation zone, and to achieve representations of the coagulated areas in three-dimensional spaces.

MATERIALS AND METHODS: Four commercially available RF devices (perfusion, internally cooled cluster, and nine- and 12-tine expandable electrodes) that represent the most widely used systems on the market were tested. Sixteen in vivo ablation procedures were performed in porcine livers (four ablations for each RF system). After macroscopic and histopathologic analyses of 3-mm-thick liver sections, morphometric and volumetric findings in the central zone of white coagulation necrosis were assessed. Coagulation volume, diameter, length, and shape were determined digitally. After analysis of variance, measurements with each system were tested with the Tukey post hoc test.

RESULTS: Mean coagulation volumes were 31.5 cm3 ± 15.8 (SD) for the perfusion electrode, 20.5 cm3 ± 2.6 for the cluster electrode, 16.2 cm3 ± 7.3 for the 12-tine electrode, and 9.8 cm3 ± 3.2 for the nine-tine electrode (P < .05, perfusion vs nine-tine electrode). No significant differences were observed regarding the mean short axis perpendicular to the needle shaft: 2.30 cm ± 0.94, 3.04 cm ± 0.26, 3.44 cm ± 0.21, and 2.70 cm ± 0.76, respectively. Variation coefficients were 0.50, 0.13, 0.45, and 0.33, respectively.

CONCLUSION: Larger coagulation volumes were obtained with the perfusion and internally cooled cluster devices. More spherical volumes of ablation were achieved with the 12-tine and cluster electrodes. The former proved superior with regard to the short axis perpendicular to the needle shaft. The cluster and nine-tine electrode produced better reproducibility, which is suggestive of improved predictability of the extent of coagulation with these systems.

© RSNA, 2004

Index terms: Animals • Experimental study, 761.1269 • Liver, interventional procedures, 761.1269 • Radiofrequency (RF) ablation, 761.1269




This article has been cited by other articles:


Home page
RadiologyHome page
O. Seror, G. N'Kontchou, M. Ibraheem, Y. Ajavon, C. Barrucand, N. Ganne, E. Coderc, J. Claude Trinchet, M. Beaugrand, and N. Sellier
Large (>=5.0-cm) HCCs: Multipolar RF Ablation with Three Internally Cooled Bipolar Electrodes--Initial Experience in 26 Patients
Radiology, May 15, 2008; (2008) 2481071101.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
H. C. Fernando
Radiofrequency Ablation to Treat Non-Small Cell Lung Cancer and Pulmonary Metastases
Ann. Thorac. Surg., February 1, 2008; 85(2): S780 - S784.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. F. Laeseke, T. M. Frey, C. L. Brace, L. A. Sampson, T. C. Winter III, J. R. Ketzler, and F. T. Lee Jr.
Multiple-Electrode Radiofrequency Ablation of Hepatic Malignancies: Initial Clinical Experience
Am. J. Roentgenol., June 1, 2007; 188(6): 1485 - 1494.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
S. Mulier, Y. Ni, L. Frich, F. Burdio, A. L. Denys, J.-F. De Wispelaere, B. Dupas, N. Habib, M. Hoey, M. C. Jansen, et al.
Experimental and Clinical Radiofrequency Ablation: Proposal for Standardized Description of Coagulation Size and Geometry
Ann. Surg. Oncol., April 1, 2007; 14(4): 1381 - 1396.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. F. Laeseke, L. A. Sampson, D. Haemmerich, C. L. Brace, J. P. Fine, T. M. Frey, T. C. Winter III, and F. T. Lee Jr
Multiple-Electrode Radiofrequency Ablation Creates Confluent Areas of Necrosis: In Vivo Porcine Liver Results
Radiology, October 1, 2006; 241(1): 116 - 124.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J M Lee, J K Han, J M Chang, S Y Chung, S H Kim, J Y Lee, and B I Choi
Radiofrequency ablation in pig lungs: in vivo comparison of internally cooled, perfusion and multitined expandable electrodes.
Br. J. Radiol., July 1, 2006; 79(943): 562 - 571.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. U. Hines-Peralta, N. Pirani, P. Clegg, N. Cronin, T. P. Ryan, Z. Liu, and S. N. Goldberg
Microwave Ablation: Results with a 2.45-GHz Applicator in ex Vivo Bovine and in Vivo Porcine Liver
Radiology, April 1, 2006; 239(1): 94 - 102.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Clasen, D. Schmidt, A. Boss, K. Dietz, S. M. Krober, C. D. Claussen, and P. L. Pereira
Multipolar Radiofrequency Ablation with Internally Cooled Electrodes: Experimental Study in ex Vivo Bovine Liver with Mathematic Modeling
Radiology, March 1, 2006; 238(3): 881 - 890.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Shibata, T. Shibata, Y. Maetani, H. Isoda, and M. Hiraoka
Radiofrequency Ablation for Small Hepatocellular Carcinoma: Prospective Comparison of Internally Cooled Electrode and Expandable Electrode
Radiology, January 1, 2006; 238(1): 346 - 353.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Boss, S. Clasen, M. Kuczyk, A. Anastasiadis, D. Schmidt, C. D. Claussen, F. Schick, and P. L. Pereira
Thermal Damage of the Genitofemoral Nerve Due to Radiofrequency Ablation of Renal Cell Carcinoma: A Potentially Avoidable Complication
Am. J. Roentgenol., December 1, 2005; 185(6): 1627 - 1631.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. M. Lee, J. K. Han, S. H. Kim, S. H. Choi, S. K. An, C. J. Han, and B. I. Choi
Bipolar Radiofrequency Ablation Using Wet-Cooled Electrodes: An In Vitro Experimental Study in Bovine Liver
Am. J. Roentgenol., February 1, 2005; 184(2): 391 - 397.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.