Breast Imaging |
1 From The Elizabeth Wende Breast Clinic, 170 Sawgrass Dr, Rochester, NY 14620. From the 2001 RSNA scientific assembly. Received January 15, 2003; revision requested March 26; final revision received November 12; accepted January 5, 2004. Address correspondence to K.M.W. (e-mail: kmw@ewbc.com) or S.V.D. (e-mail: sdestounis@ewbc.com).
PURPOSE: To retrospectively evaluate the role of computer-aided detection (CAD) in reducing the rate of false-negative (FN) findings on screening mammograms considered normal at initial double reading.
MATERIALS AND METHODS: At the authors institution, independent prospective double readings in which the second reader is not blinded to results of the first reading are performed routinely for all mammograms. When cancer is diagnosed, prior mammograms also are reviewed with double reading to determine cancer visibility. Findings are categorized as (a) no evidence of cancer on any prior screening mammogram and patient presents more than 1 year after prior screening, (b) no evidence of cancer on any prior screening mammogram and patient presents with symptoms within 1 year after prior screening (year-interval occult false-negative), or (c) cancer visible. The clinical director separately evaluates each case in the same way. In 2000, 519 histologically proved breast cancers were diagnosed, including 132 for which patients sought a second opinion and FN findings were not tracked. Prior screening mammograms were available in 318 of the other 387 cases. Five radiologists in two reading sessions independently reviewed current and prior mammograms to categorize visible cancers as either threshold or actionable FN findings. Visible cancers deemed actionable by at least three of five readers were analyzed with a commercially available CAD system. FN rates were calculated prior to and after CAD analysis.
RESULTS: Twenty-seven occult and 71 visible cancers were found (total FN findings, 98). Three of five readers considered 52 (73%) of 71 visible cancers actionable. The CAD system correctly marked 37 (71%) of these 52 on prior screening mammograms (19 [65%] of 29 masses, seven [88%] of eight microcalcifications, seven [78%] of nine architectural distortions, and four [67%] of six masses with microcalcifications). The FN rate was 98 (31%) of 318 before CAD and 61 (19%) of 318 after CAD.
CONCLUSION: In this retrospective review of this small subset of cancers, it appears that CAD has the potential to decrease the FN rate at double reading by more than one-third (from 31% to 19%). The CAD system correctly marked 37 (71%) of 52 actionable findings read as negative in previous screening years.
© RSNA, 2004
Index terms: Breast neoplasms, radiography, 08.11 Breast radiography, quality assurance Computers, diagnostic aid
This article has been cited by other articles:
![]() |
M. Gromet Comparison of Computer-Aided Detection to Double Reading of Screening Mammograms: Review of 231,221 Mammograms Am. J. Roentgenol., April 1, 2008; 190(4): 854 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kakeda, Y. Korogi, H. Arimura, T. Hirai, S. Katsuragawa, T. Aoki, and K. Doi Diagnostic Accuracy and Reading Time to Detect Intracranial Aneurysms on MR Angiography Using a Computer-Aided Diagnosis System Am. J. Roentgenol., February 1, 2008; 190(2): 459 - 465. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Georgian-Smith, R. H. Moore, E. Halpern, E. D. Yeh, E. A. Rafferty, H. A. D'Alessandro, M. Staffa, D. A. Hall, K. A. McCarthy, and D. B. Kopans Blinded Comparison of Computer-Aided Detection with Human Second Reading in Screening Mammography Am. J. Roentgenol., November 1, 2007; 189(5): 1135 - 1141. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. F. Brem Blinded Comparison of Computer-Aided Detection with Human Second Reading in Screening Mammography: The Importance of the Question and the Critical Numbers Game Am. J. Roentgenol., November 1, 2007; 189(5): 1142 - 1144. [Full Text] [PDF] |
||||
![]() |
R. L. Ellis, A. A. Meade, M. A. Mathiason, K. M. Willison, and W. Logan-Young Evaluation of Computer-aided Detection Systems in the Detection of Small Invasive Breast Carcinoma Radiology, October 1, 2007; 245(1): 88 - 94. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Skaane, A. Kshirsagar, S. Stapleton, K. Young, and R. A. Castellino Effect of Computer-Aided Detection on Independent Double Reading of Paired Screen-Film and Full-Field Digital Screening Mammograms Am. J. Roentgenol., February 1, 2007; 188(2): 377 - 384. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Taplin, C. M. Rutter, and C. D. Lehman Testing the effect of computer-assisted detection on interpretive performance in screening mammography. Am. J. Roentgenol., December 1, 2006; 187(6): 1475 - 1482. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Ko, M. J. Nicholas, J. B. Mendel, and P. J. Slanetz Prospective assessment of computer-aided detection in interpretation of screening mammography. Am. J. Roentgenol., December 1, 2006; 187(6): 1483 - 1491. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. R. Pai, N. E. Gregory, A. E. Swinford, and M. Rebner Ductal Carcinoma in Situ: Computer-aided Detection in Screening Mammography Radiology, December 1, 2006; 241(3): 689 - 694. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. J. Gilbert, S. M. Astley, M. A. McGee, M. G. C. Gillan, C. R. M. Boggis, P. M. Griffiths, and S. W. Duffy Single Reading with Computer-aided Detection and Double Reading of Screening Mammograms in the United Kingdom National Breast Screening Program Radiology, October 1, 2006; 241(1): 47 - 53. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. S. Dua, C. M. Isacke, and G. P.H. Gui The Intraductal Approach to Breast Cancer Biomarker Discovery J. Clin. Oncol., March 1, 2006; 24(7): 1209 - 1216. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Mouchawar, S. Taplin, L. Ichikawa, W. E. Barlow, A. M. Geiger, S. Weinmann, J. Gilbert, M. M. Manos, and M. U. Yood Late-Stage Breast Cancer Among Women With Recent Negative Screening Mammography: Do Clinical Encounters Offer Opportunity for Earlier Detection? J Natl Cancer Inst Monographs, November 1, 2005; 2005(35): 39 - 46. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Hirai, Y. Korogi, H. Arimura, S. Katsuragawa, M. Kitajima, M. Yamura, Y. Yamashita, and K. Doi Intracranial Aneurysms at MR Angiography: Effect of Computer-aided Diagnosis on Radiologists' Detection Performance Radiology, November 1, 2005; 237(2): 605 - 610. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. V. Ghate, M. S. Soo, J. A. Baker, R. Walsh, E. I. Gimenez, and E. L. Rosen Comparison of Recall and Cancer Detection Rates for Immediate versus Batch Interpretation of Screening Mammograms Radiology, April 1, 2005; 235(1): 31 - 35. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |