Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2323030359
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tanigaki, S.
Right arrow Articles by Yoshimura, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tanigaki, S.
Right arrow Articles by Yoshimura, Y.
(Radiology 2004;232:767-772.)
© RSNA, 2004


Obstetric Imaging

Pulmonary Hypoplasia: Prediction with Use of Ratio of MR Imaging–measured Fetal Lung Volume to US-estimated Fetal Body Weight1

Shinji Tanigaki, MD, Kei Miyakoshi, MD, Mamoru Tanaka, MD, Yoshihisa Hattori, MD, Tadashi Matsumoto, MD, Kazunori Ueno, MD, Katsuhiko Uehara, MD, Osamu Nishimura, MD, Kazuhiro Minegishi, MD, Hitoshi Ishimoto, MD, Hiroshi Shinmoto, MD, Kazushige Ikeda, MD and Yasunori Yoshimura, MD

1 From Depts of Obstetrics and Gynecology (S.T., M.T., Y.H., T.M., K. Ueno, K. Uehara, O.N., K. Miyakoshi, K. Minegishi, H.I., Y.Y.), Diagnostic Radiology (H.S.), and Pediatrics (K.I.), School of Medicine, Keio University, Tokyo, Japan. Received Mar 6, 2003; revision requested May 23; final revision received Nov 17; accepted Jan 5, 2004. Address correspondence to K. Miyakoshi, Div of Reproductive Sciences, Oregon National Primate Research Center, 505 NW 185th Ave, Beaverton, OR 97006 (e-mail: miyakosh@ohsu.edu).

PURPOSE: To determine the ratio of fetal lung volume (FLV) to fetal body weight (FBW) by using ultrasonography (US) and magnetic resonance (MR) imaging and to evaluate the usefulness of this ratio in predicting pulmonary hypoplasia (PH) in fetuses at high risk.

MATERIALS AND METHODS: MR imaging lung volumetry and US biometry were performed in 90 fetuses at 25–39 weeks gestation. In the control group of 73 fetuses, normal lung development was confirmed at neonatal follow-up and the normative ratio of MR imaging–measured FLV to US-estimated FBW (FLV/FBW) was determined. The high-risk group included 17 fetuses at risk for PH. The FLV/FBW was compared between the control and high-risk groups and with US parameters for predicting the development of PH in the high-risk group. Measurements 2 or more standard deviations below the mean control group measurement were considered abnormal. Comparisons of the FLV/FBW between groups were made by using the Student t test. The association between development of PH and measurement of each parameter was analyzed by using the Fisher exact probability test.

RESULTS: In the control group, the FLV/FBW decreased with gestational age during the third trimester and had a normal distribution (mean ratio, 0.028 mL/g; range, 0.015–0.444 mL/g). The mean FLV/FBW for the nine fetuses with PH (0.012 mL/g ± 0.008) was significantly lower (P < .001) than that for the control group (0.028 mL/g ± 0.007). Fetuses with abnormal FLV/FBW values were at significantly greater risk (P < .05) for PH development. Abnormal FLV/FBW values had higher diagnostic accuracy than abnormal US parameters. Sensitivity of the FLV/FBW was 89% (eight of nine fetuses); specificity, 88% (seven of eight fetuses); positive predictive value, 89% (eight of nine fetuses); negative predictive value, 88% (seven of eight fetuses); and accuracy, 88% (15 of 17 fetuses).

CONCLUSION: The FLV/FBW reflects the adequacy of intrauterine lung growth and can help predict PH.

© RSNA, 2004

Index terms: Fetus, growth and development • Fetus, MR, 60.121411, 60.121412, 60.121416 • Fetus, respiratory system • Fetus, US, 60.12981, 60.12989 • Lung, congenital malformation, 60.14




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
R. Ruano, M.-C. Aubry, Y. Dumez, M. Zugaib, and A. Benachi
Predicting Neonatal Deaths and Pulmonary Hypoplasia in Isolated Congenital Diaphragmatic Hernia Using the Sonographic Fetal Lung Volume-Body Weight Ratio
Am. J. Roentgenol., May 1, 2008; 190(5): 1216 - 1219.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. L. Ward, M. Nishino, H. Hatabu, J. A. Estroff, C. E. Barnewolt, H. A. Feldman, and D. Levine
Fetal Lung Volume Measurements: Determination with MR Imaging--Effect of Various Factors.
Radiology, July 1, 2006; 240(1): 187 - 193.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
C. F. A. Peralta, J. F. Kazan-Tannus, V. Bunduki, E. M. Santos, C. C. de Castro, G. G. Cerri, and M. Zugaib
Evaluation of the Agreement Between 3-Dimensional Ultrasonography and Magnetic Resonance Imaging for Fetal Lung Volume Measurement
J. Ultrasound Med., April 1, 2006; 25(4): 461 - 467.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
L. F. Goncalves, W. Lee, J. Espinoza, and R. Romero
Three- and 4-Dimensional Ultrasound in Obstetric Practice: Does It Help?
J. Ultrasound Med., December 1, 2005; 24(12): 1599 - 1624.
[Abstract] [Full Text] [PDF]