Experimental Studies |
1 From the Departments of Diagnostic Radiology (A.C.L., S.G., A.B., W.S.R.), Pathology (S.v.G., R.M.B.), and Cardiology/Angiology (F.R.M.), Justus-Liebig-University, Langhansstrasse 10, D-35392 Giessen, Germany; and Department of Internal Medicine/Angiology, University of Bochum, Bochum, Germany (B.L.). From the 2003 RSNA scientific assembly. Received August 21, 2003; revision requested October 21; final revision received March 17, 2004; accepted April 1. Address correspondence to R.M.B. (e-mail: rainer.bohle@patho.med.uni-giessen.de).
PURPOSE: To evaluate the feasibility of microcomputed tomography (CT) for analysis of the lung fine structure and its alterations during endotoxin-induced lung injury.
MATERIALS AND METHODS: Intravital perfusion-fixed rat lungs with (n = 5) and without (n = 5) endotoxin perfusion were scanned with micro-CT. Three imaging modalities (conventional histology, intravital microscopy, and electron microscopy) were used to document the effect of endotoxin and the in vivo application of contrast agent (a mixture of barium sulfate, gelatin, and thymol). The effect of endotoxin on structural changes of the lung was evaluated with analysis of variance.
RESULTS: Intravital microscopy, conventional histology, and electron microscopy demonstrated capillary perfusion of contrast agent, inflated alveoli, and no extravasation of barium sulfate in the extravascular space. Systemic application of endotoxin led to a significant increase in the soft-tissue volume of the lungs (ie, tissue edema) (58.09 µm3± 4.6 [standard error of the mean] vs 8.31 µm3± 1.63, P < .001) and significant thickening of the alveolar walls (34.01 µm ± 4.5 vs 14.83 µm ± 2.5, P < .001) at micro-CT. Simultaneously, endotoxin-treated rat lungs showed a significant reduction in total air space (49.74 µm3± 1.72 vs 100.99 µm3± 1.16, P < .001).
CONCLUSION: These findings indicate that micro-CT is feasible for structural evaluation of the lung fine structure and its alterations during endotoxin-induced lung injury.
© RSNA, 2004
Index terms: Animals Computed tomography (CT), contrast enhancement Computed tomography (CT), technology Computed tomography (CT), tissue characterization, 60.1211 Experimental study Lung, CT, 60.1211
This article has been cited by other articles:
![]() |
N. L. Ford, E. L. Martin, J. F. Lewis, R. A. W. Veldhuizen, M. Drangova, and D. W. Holdsworth In vivo characterization of lung morphology and function in anesthetized free-breathing mice using micro-computed tomography J Appl Physiol, May 1, 2007; 102(5): 2046 - 2055. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Ying and T. M. Monticello Modern Imaging Technologies in Toxicologic Pathology: An Overview Toxicol Pathol, December 1, 2006; 34(7): 815 - 826. [Abstract] [Full Text] [PDF] |
||||