Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2331031505
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kalra, M. K.
Right arrow Articles by Saini, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kalra, M. K.
Right arrow Articles by Saini, S.
(Radiology 2004;233:241-249.)
© RSNA, 2004


Gastrointestinal Imaging

Sixteen–Detector Row CT of Abdomen and Pelvis: Study for Optimization of Z-Axis Modulation Technique Performed in 153 Patients1

Mannudeep K. Kalra, MD, DNB, Michael M. Maher, MD, FFR (RCSI), FRCR, Ravi S. Kamath, MD, PhD, Tetsuya Horiuchi, PhD, Thomas L. Toth, DSc, Elkan F. Halpern, PhD and Sanjay Saini, MD

1 From the Department of Radiology, Division of Abdominal Imaging and Intervention, Massachusetts General Hospital and Harvard Medical School, White 270-E, 55 Fruit St, Boston, MA 02114 (M.K.K., M.M.M., R.S.K., E.F.H., S.S.); GE Yokogawa Medical Systems, Tokyo, Japan (T.H.); and GE Medical Systems, Waukesha, Wis (T.L.T.). From the 2003 RSNA scientific assembly. Received September 17, 2003; revision requested December 2; revision received January 6, 2004; accepted February 2. Address correspondence to M.K.K. (e-mail: mannudeep_k_kalra@yahoo.com).

PURPOSE: To retrospectively determine the optimal noise indexes required to obtain diagnostically acceptable computed tomographic (CT) images of the abdomen and pelvis with z-axis modulation.

MATERIALS AND METHODS: Ninety-five patients underwent 16-section multi–detector row CT of the abdomen and pelvis with z-axis modulation at noise indexes of 10.5, 11.0, 11.5, and 12.0 HU with 10–380 mA. Subsequently, 58 patients were scanned at noise indexes of 12.5 and 15.0 HU with 75–380 mA. The weights of all subjects were recorded, and transverse and anteroposterior diameters were measured. The CT images were evaluated for abnormalities and graded for image quality in terms of noise and diagnostic acceptability by using a five-point scale. Objective noise in the liver parenchyma was measured, and the tube current was recorded at each section in all 153 patients. Statistical analyses were performed to determine the appropriate noise index and to assess the effect of patient weight and abdominal diameters on image noise and diagnostic acceptability at different noise indexes. Tube current–time products (in milliampere seconds) at various noise indexes were compared with those at CT previously performed without z-axis modulation.

RESULTS: No significant difference in subjective image noise or diagnostic acceptability was found at noise indexes of 10.5–15.0 HU (P = .14), and objective noise was significantly inferior only at a noise index of 15.0 HU (P = .009). Compared with CT scanning at a 10.5-HU noise index, CT scanning at 12.5- and 15.0-HU noise indexes yielded, respectively, 10.0% and 41.3% reductions in radiation exposure. Patient weight and abdominal diameters affected subjective image quality.

CONCLUSION: Use of a 15.0-HU noise index at 75–380 mA results in acceptable subjective image noise and diagnostic acceptability but significantly greater objective image noise at routine abdominal-pelvic CT. For greater image quality demands, a noise index of 12.5 HU results in acceptable image quality and a 19.6% reduction in radiation exposure.

© RSNA, 2004

Index terms: Abdomen, CT, 70.12111 • Computed tomography (CT), image quality • Computed tomography (CT), radiation exposure • Pelvis, CT, 813.12111




This article has been cited by other articles:


Home page
RadiologyHome page
T. Miyoshi, M. Kanematsu, H. Kondo, S. Goshima, Y. Tsuge, A. Hatcho, Y. Shiratori, M. Onozuka, N. Moriyama, and K. T. Bae
Abdomen: Angiography with 16-Detector CT--Comparison of Image Quality and Radiation Dose between Studies with 0.625-mm and those with 1.25-mm Collimation
Radiology, October 1, 2008; 249(1): 142 - 150.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Roggenland, S. A. Peters, S. P. Lemburg, T. Holland-Letz, V. Nicolas, and C. M. Heyer
CT Angiography in Suspected Pulmonary Embolism: Impact of Patient Characteristics and Different Venous Lines on Vessel Enhancement and Image Quality
Am. J. Roentgenol., June 1, 2008; 190(6): W351 - W359.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Herzog, D. M. Mulvihill, S. A. Nguyen, G. Savino, B. Schmidt, P. Costello, T. J. Vogl, and U. J. Schoepf
Pediatric Cardiovascular CT Angiography: Radiation Dose Reduction Using Automatic Anatomic Tube Current Modulation
Am. J. Roentgenol., May 1, 2008; 190(5): 1232 - 1240.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. A. Jaffe, T. T. Yoshizumi, G. I. Toncheva, G. Nguyen, L. M. Hurwitz, and R. C. Nelson
Early First-Trimester Fetal Radiation Dose Estimation in 16-MDCT Without and With Automated Tube Current Modulation
Am. J. Roentgenol., April 1, 2008; 190(4): 860 - 864.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. T. Schindera, R. C. Nelson, T. L. Toth, G. T. Nguyen, G. I. Toncheva, D. M. DeLong, and T. T. Yoshizumi
Effect of Patient Size on Radiation Dose for Abdominal MDCT with Automatic Tube Current Modulation: Phantom Study
Am. J. Roentgenol., February 1, 2008; 190(2): W100 - W105.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Matsubara, K. Koshida, M. Suzuki, H. Tsujii, T. Yamamoto, and O. Matsui
Comparison between 3-D and z-axis automatic tube current modulation technique in multidetector-row CT
Radiat Prot Dosimetry, January 1, 2008; 128(1): 106 - 111.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Coursey, D. P. Frush, T. Yoshizumi, G. Toncheva, G. Nguyen, and S. B. Greenberg
Pediatric Chest MDCT Using Tube Current Modulation: Effect on Radiation Dose with Breast Shielding
Am. J. Roentgenol., January 1, 2008; 190(1): W54 - W61.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. T. Schindera, R. C. Nelson, S. Mukundan Jr, E. K. Paulson, T. A. Jaffe, C. M. Miller, D. M. DeLong, K. Kawaji, T. T. Yoshizumi, and E. Samei
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multi Detector Row CT for Enhanced Detection Phantom Study
Radiology, December 1, 2007; 246(1): 125 - 132.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
D. D. Cody and M. Mahesh
AAPM/RSNA Physics Tutorials AAPM/RSNA Physics Tutorial for Residents: Technologic Advances in Multidetector CT with a Focus on Cardiac Imaging
RadioGraphics, November 1, 2007; 27(6): 1829 - 1837.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
A J Van Der Molen, W J H Veldkamp, and J Geleijns
16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys
Br. J. Radiol., April 1, 2007; 80(952): 248 - 255.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Li, U. K. Udayasankar, T. L. Toth, J. Seamans, W. C. Small, and M. K. Kalra
Automatic Patient Centering for MDCT: Effect on Radiation Dose
Am. J. Roentgenol., February 1, 2007; 188(2): 547 - 552.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
N. C. Dalrymple, S. R. Prasad, F. M. El-Merhi, and K. N. Chintapalli
Price of Isotropy in Multidetector CT
RadioGraphics, January 1, 2007; 27(1): 49 - 62.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Namasivayam, M.K. Kalra, K.M. Pottala, S.M. Waldrop, and P.A. Hudgins
Optimization of Z-Axis Automatic Exposure Control for Multidetector Row CT Evaluation of Neck and Comparison with Fixed Tube Current Technique for Image Quality and Radiation Dose
AJNR Am. J. Neuroradiol., November 1, 2006; 27(10): 2221 - 2225.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Graser, B. J. Wintersperger, C. Suess, M. F. Reiser, and C. R. Becker
Dose reduction and image quality in MDCT colonography using tube current modulation.
Am. J. Roentgenol., September 1, 2006; 187(3): 695 - 701.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Rizzo, M. Kalra, B. Schmidt, T. Dalal, C. Suess, T. Flohr, M. Blake, and S. Saini
Comparison of Angular and Combined Automatic Tube Current Modulation Techniques with Constant Tube Current CT of the Abdomen and Pelvis.
Am. J. Roentgenol., March 1, 2006; 186(3): 673 - 679.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, S. Rizzo, M. M. Maher, E. F. Halpern, T. L. Toth, J.-A. O. Shepard, and S. L. Aquino
Chest CT Performed with Z-Axis Modulation: Scanning Protocol and Radiation Dose
Radiology, October 1, 2005; 237(1): 303 - 308.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
V. M. Chapman, M. Kalra, E. Halpern, B. Grottkau, M. Albright, and D. Jaramillo
16-MDCT of the Posttraumatic Pediatric Elbow: Optimum Parameters and Associated Radiation Dose
Am. J. Roentgenol., August 1, 2005; 185(2): 516 - 521.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, R. V. D'Souza, S. Rizzo, E. F. Halpern, M. A. Blake, and S. Saini
Detection of Urinary Tract Stones at Low-Radiation-Dose CT with Z-Axis Automatic Tube Current Modulation: Phantom and Clinical Studies
Radiology, May 1, 2005; 235(2): 523 - 529.
[Abstract] [Full Text] [PDF]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
T. J. Vrtiska, J. G. Fletcher, and C. H. McCollough
State-of-the-Art Imaging With 64-Channel Multidetector CT Angiography
Perspectives in Vascular Surgery and Endovascular Therapy, March 1, 2005; 17(1): 3 - 8.
[Abstract] [PDF]


Home page
Am. J. Roentgenol.Home page
S. M. R. Rizzo, M. K. Kalra, M. M. Maher, M. A. Blake, T. L. Toth, and S. Saini
Do Metallic Endoprostheses Increase Radiation Dose Associated with Automatic Tube-Current Modulation in Abdominal-Pelvic MDCT? A Phantom and Patient Study
Am. J. Roentgenol., February 1, 2005; 184(2): 491 - 496.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, T. L. Toth, B. Schmidt, B. L. Westerman, H. T. Morgan, and S. Saini
Techniques and Applications of Automatic Tube Current Modulation for CT
Radiology, December 1, 2004; 233(3): 649 - 657.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.