Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print September 9, 2004, 10.1148/radiol.2332031200
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2332031200v1
233/2/411    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baker, J. A.
Right arrow Articles by Floyd, C. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baker, J. A.
Right arrow Articles by Floyd, C. E.
(Radiology 2004;233:411-417.)
© RSNA, 2004


Breast Imaging

Computer-aided Detection in Screening Mammography: Variability in Cues1

Jay A. Baker, MD, Joseph Y. Lo, PhD, David M. Delong, PhD and Carey E. Floyd, PhD

1 From the Departments of Radiology and Biomedical Engineering, Duke University Medical Center, Erwin Rd, Durham, NC 27710. From the 2003 RSNA scientific assembly. Received July 28, 2003; revision requested October 6; revision received January 24, 2004; accepted March 2. Address correspondence to J.A.B. (e-mail: jay.baker@duke.edu).

PURPOSE: To evaluate the variability of true-positive and false-positive cues by using a commercially available computer-aided detection (CAD) system for analysis of 50 malignancies in a screening population.

MATERIALS AND METHODS: Fifty breast cancers detected at screening were analyzed by using a commercially available CAD system. Mean patient age was 62.2 years. Each set of mammograms (craniocaudal and mediolateral oblique views) was digitized and analyzed by the CAD system 10 times. One radiologist compared CAD output with the location of the malignancy at mammography and determined whether each lesion was marked accurately in one mammographic view, both views, or neither. Sensitivity and reproducibility of the CAD system were determined for both case- and image-based analysis.

RESULTS: Overall sensitivity of the CAD system when at least one of the two mammographic views was marked correctly (case-base sensitivity) was 82.4%. Sensitivity when each mammographic view was considered separately (image-based sensitivity) was 61.1%. For case-based analysis, variability in true-positive CAD cues was demonstrated for 14 of 50 (28%) cases. For image-based analysis, inconsistency in CAD output was observed in 33 of 100 (33%) mammographic views that contained malignancies detected at screening. However, the CAD system consistently detected 40–43 of the 50 breast cancers in each of the 10 CAD runs. Variability for false-positive marks was significantly greater than that for true-positive marks.

CONCLUSION: Inconsistency was demonstrated for CAD analysis of breast cancers detected at screening. However, the CAD system was reasonably consistent in the overall number of cancers identified from run to run. Greater variability of the CAD system was also demonstrated for false-positive marks, as compared with true-positive marks.

© RSNA, 2004

Index terms: Breast neoplasms, localization, 08.112, 08.115 • Breast radiography, quality assurance, 08.112, 08.115 • Computers, diagnostic aid




This article has been cited by other articles:


Home page
RadiologyHome page
S. J. Kim, W. K. Moon, N. Cho, J. H. Cha, S. M. Kim, and J.-G. Im
Computer-aided Detection in Full-Field Digital Mammography: Sensitivity and Reproducibility in Serial Examinations
Radiology, December 1, 2007; 246(1): 71 - 80.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. K. Yang, W. K. Moon, N. Cho, J. S. Park, J. H. Cha, S. M. Kim, S. J. Kim, and J.-G. Im
Screening Mammography-detected Cancers: Sensitivity of a Computer-aided Detection System Applied to Full-Field Digital Mammograms
Radiology, July 1, 2007; 244(1): 104 - 111.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. J. Kim, W. K. Moon, N. Cho, J. H. Cha, S. M. Kim, and J.-G. Im
Computer-aided Detection in Digital Mammography: Comparison of Craniocaudal, Mediolateral Oblique, and Mediolateral Views
Radiology, December 1, 2006; 241(3): 695 - 701.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. J. Brenner, M. J. Ulissey, and R. M. Wilt
Computer-Aided Detection as Evidence in the Courtroom: Potential Implications of an Appellate Court's Ruling
Am. J. Roentgenol., January 1, 2006; 186(1): 48 - 51.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.