Vascular and Interventional Radiology |
1 From the Department of Radiology, Hôpital Calmette, University Center of Lille, Blvd Jules Leclerc, 59037 Lille, France. Received January 9, 2004; revision requested March 11; revision received April 1; accepted May 17. Address correspondence to M.R.J. (e-mail: mremy-jardin@chru-lille.fr).
PURPOSE: To retrospectively evaluate bronchial and nonbronchial systemic arteries at multidetector row helical computed tomography (CT) compared with conventional angiography in patients undergoing endovascular treatment of hemoptysis.
MATERIALS AND METHODS: Neither institutional board approval nor informed consent was required. Forty-eight consecutive patients (39 men, nine women; mean age, 55.7 years; range, 2082 years) with hemoptysis of bronchial and nonbronchial systemic artery origin underwent multidetector row helical CT angiography of the thorax with use of a fourdetector row (n = 31) or 16detector row (n = 17) scanner prior to embolization. Findings on CT angiograms, including CT scans, maximum intensity projections, and three-dimensional volume-rendered images, were used to evaluate the depiction of bronchial and nonbronchial systemic arteries. Retrospective analysis of the ostium and the course of bronchial and/or nonbronchial systemic arteries on CT angiograms enabled evaluation of the accuracy of this technique in identification of the relevant vasculature.
RESULTS: Among the 46 patients initially treated with bronchial artery embolization, 58 bronchial arteries were identified at CT and/or angiography. In 50 (86%) cases, concordant findings were observed with both modalities. In five (9%) cases, CT could not be used to identify the ostia of bronchial arteries. In three (5%) cases, CT depicted bronchial arteries that could not be selectively catheterized. Three-dimensional images were found to be superior to transverse CT scans in depicting the ectopic origin of the bronchial arteries, which enabled the interventional radiologists to perform successful embolization after direct catherization of the ectopic vessel in every case. In five (11%) patients, the nonbronchial systemic origin of bronchial bleeding was identified on CT angiograms.
CONCLUSION: Multidetector row helical CT angiography provides more precise depiction of bronchial and nonbronchial systemic arteries than does conventional angiography.
© RSNA, 2004
Index terms: Angiography, comparative studies, 94.1211, 94.12916 Arteries, bronchial Computed tomography (CT), angiography, 94.12915, 94.12916, 94.12917 Lung, hemorrhage
This article has been cited by other articles:
![]() |
A. SIRAJUDDIN and T.-L. H. MOHAMMED A 44-year-old man with hemoptysis: a review of pertinent imaging studies and radiographic interventions. Cleveland Clinic Journal of Medicine, August 1, 2008; 75(8): 601 - 607. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Matsuura, K. Takase, H. Ota, T. Yamada, A. Sato, F. Satoh, and S. Takahashi Radiologic Anatomy of the Right Adrenal Vein: Preliminary Experience with MDCT Am. J. Roentgenol., August 1, 2008; 191(2): 402 - 408. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Sugita, T. Yamazaki, N. Fujita, T. Naitoh, M. Kobari, and S. Takahashi Cystic Artery and Cystic Duct Assessment with 64-Detector Row CT before Laparoscopic Cholecystectomy Radiology, July 1, 2008; 248(1): 124 - 131. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Khalil, A. Parrot, C. Nedelcu, M. Fartoukh, C. Marsault, and M.-F. Carette Severe Hemoptysis of Pulmonary Arterial Origin: Signs and Role of Multidetector Row CT Angiography Chest, January 1, 2008; 133(1): 212 - 219. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Poyanli, B Acunas, I Rozanes, K Guven, S Yilmaz, A Salmaslioglu, E Terzibasioglu, and R Cirpin Endovascular therapy in the management of moderate and massive haemoptysis Br. J. Radiol., May 1, 2007; 80(953): 331 - 336. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Khalil, M. Fartoukh, M. Tassart, A. Parrot, C. Marsault, and M.-F. Carette Role of MDCT in Identification of the Bleeding Site and the Vessels Causing Hemoptysis Am. J. Roentgenol., February 1, 2007; 188(2): W117 - W125. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Khalil, M Soussan, G Mangiapan, M Fartoukh, A Parrot, and M-F Carette Utility of high-resolution chest CT scan in the emergency management of haemoptysis in the intensive care unit: severity, localization and aetiology Br. J. Radiol., January 1, 2007; 80(949): 21 - 25. [Abstract] [Full Text] [PDF] |
||||
![]() |
P.-Y. Brillet, P. Dumont, N. Bouaziz, A. Duhamel, F. Laurent, J. Remy, and M. Remy-Jardin Pulmonary Arteriovenous Malformation Treated with Embolotherapy: Systemic Collateral Supply at Multidetector CT Angiography after 2-20-year Follow-up Radiology, December 1, 2006; 242(1): 267 - 276. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Coulden State-of-the-Art Imaging Techniques in Chronic Thromboembolic Pulmonary Hypertension Proceedings of the ATS, September 1, 2006; 3(7): 577 - 583. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nael, H. J. Michaely, U. Kramer, M. H. Lee, J. Goldin, G. Laub, and J. P. Finn Pulmonary Circulation: Contrast-enhanced 3.0-T MR Angiography--Initial Results Radiology, September 1, 2006; 240(3): 858 - 868. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Chung, J. H. Lee, K. S. Lee, Y. C. Yoon, O J. Kwon, and T. S. Kim Bronchial and Nonbronchial Systemic Arteries in Patients with Hemoptysis: Depiction on MDCT Angiography. Am. J. Roentgenol., March 1, 2006; 186(3): 649 - 655. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Bruzzi, M. Remy-Jardin, D. Delhaye, A. Teisseire, C. Khalil, and J. Remy Multi-Detector Row CT of Hemoptysis RadioGraphics, January 1, 2006; 26(1): 3 - 22. [Abstract] [Full Text] [PDF] |
||||