Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2342030897
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pisano, E. D.
Right arrow Articles by Yaffe, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pisano, E. D.
Right arrow Articles by Yaffe, M. J.
(Radiology 2005;234:353-362.)
© RSNA, 2005


State of the Art

Digital Mammography1

Etta D. Pisano, MD and Martin J. Yaffe, PhD

1 From the Department of Radiology and Biomedical Engineering and UNC-Lineberger Comprehensive Cancer Center, University of North Carolina, 515 Old Infirmary, CB 7510, Chapel Hill, NC 27599 (E.D.P.); and Sunnybrook and Women’s Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada (M.J.Y.) Received June 6, 2003; revision requested August 20; revision received January 30, 2004; accepted March 17. Address correspondence to E.D.P. (e-mail: etpisano@med.unc.edu).

In digital mammography, the processes of image acquisition, display, and storage are separated, which allows optimization of each. Radiation transmitted through the breast is absorbed by an electronic detector, the response of which is faithful over a wide range of intensities. Once this information is recorded, it can be displayed by using computer image-processing techniques to allow arbitrary settings of image brightness and contrast, without the need for further exposure to the patient. In this article, the current state of the art in technology for digital mammography and data from clinical trials that support the use of the technology will be reviewed. In addition, several potentially useful applications that are being developed with digital mammography will be described.

© RSNA, 2005




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. B. Krug, H. Stutzer, R. Schroder, J. Boecker, J. Poggenborg, and K. Lackner
Image Quality of Digital Direct Flat-Panel Mammography Versus an Analog Screen-Film Technique Using a Low-Contrast Phantom
Am. J. Roentgenol., September 1, 2008; 191(3): W80 - W88.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
W. E. Muhogora, A. Devetti, R. Padovani, P. Msaki, and F. Bonutti
Application of European protocol in the evaluation of contrast-to-noise ratio and mean glandular dose for two digital mammography systems
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 231 - 236.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. K. Yang, W. K. Moon, N. Cho, J. S. Park, J. H. Cha, S. M. Kim, S. J. Kim, and J.-G. Im
Screening Mammography-detected Cancers: Sensitivity of a Computer-aided Detection System Applied to Full-Field Digital Mammograms
Radiology, July 1, 2007; 244(1): 104 - 111.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. B. Krug, H. Stutzer, R. Girnus, M. Zahringer, A. Gossmann, G. Winnekendonk, and K. Lackner
Image Quality of Digital Direct Flat-Panel Mammography Versus an Analog Screen-Film Technique Using a Phantom Model
Am. J. Roentgenol., February 1, 2007; 188(2): 399 - 407.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. A. Berns, R. E. Hendrick, M. Solari, L. Barke, D. Reddy, J. Wolfman, L. Segal, P. DeLeon, S. Benjamin, and L. Willis
Digital and screen-film mammography: comparison of image acquisition and interpretation times.
Am. J. Roentgenol., July 1, 2006; 187(1): 38 - 41.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
K C YOUNG
Recent developments in digital mammography
Imaging, June 1, 2006; 18(2): 68 - 74.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
J. H. BRUSIN
Digital Mammography: An Update
Radiol. Technol., January 1, 2006; 77(3): 226M - 234M.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. B. Wolbarst and W. R. Hendee
Evolving and Experimental Technologies in Medical Imaging
Radiology, January 1, 2006; 238(1): 16 - 39.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
E. D. Pisano, C. Gatsonis, E. Hendrick, M. Yaffe, J. K. Baum, S. Acharyya, E. F. Conant, L. L. Fajardo, L. Bassett, C. D'Orsi, et al.
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
N. Engl. J. Med., October 27, 2005; 353(17): 1773 - 1783.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. D. Pisano, C. A. Gatsonis, M. J. Yaffe, R. E. Hendrick, A. N. A. Tosteson, D. G. Fryback, L. W. Bassett, J. K. Baum, E. F. Conant, R. A. Jong, et al.
American College of Radiology Imaging Network Digital Mammographic Imaging Screening Trial: Objectives and Methodology
Radiology, August 1, 2005; 236(2): 404 - 412.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.