Thoracic Imaging |
1 From the Department of Radiology and Ludwig Boltzmann-Institute for Clinical and Experimental Radiologic Research, University of Vienna, Währinger Gürtel 1820, A-1090 Vienna, Austria. Received August 14, 2003; revision requested October 28; revision received March 18, 2004; accepted May 17. Address correspondence to M.S. (e-mail: martina.scharitzer@meduniwien.ac.at).
PURPOSE: To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode-ray tube (CRT) monitor in the detection of simulated support catheters on bedside chest radiographs.
MATERIALS AND METHODS: The ethics committee did not require approval or patient informed consent when this study began. Because of a change in regulations, before images were acquired the nature of the study and procedures were explained to patients or their relatives, and consent was then obtained. A total of 131 catheter fragments (1214 per radiograph) were superimposed over 10 anteroposterior bedside chest radiographs obtained with storage phosphor technology. Images were displayed on an LCD monitor (1536 x 2048 matrix) and a CRT monitor (2048 x 2560 matrix). Five radiologists independently located the catheter fragments and rated their confidence in detection with bright and subdued ambient light. A two-way analysis of variance and the Friedman test were used for statistical analysis.
RESULTS: There was no significant difference for either display type with respect to correctly detected catheter fragments (mean sensitivity, 56.6% and 56.0% for the CRT and the LCD monitors, respectively, with bright light and 61.2% for both monitors with subdued light). With both display types, detection rate with bright light decreased significantly (P < .05). False-positive rates and confidence ratings were not significantly affected by monitor type or ambient light.
CONCLUSION: In a study with simulation of clinical conditions, performance of the LCD monitor and high-resolution CRT monitor for detection of support catheters on bedside chest radiographs was equivalent. With both displays, detection performance was equally reduced with bright ambient light.
© RSNA, 2004
This article has been cited by other articles:
![]() |
N Buls, W Shabana, P Verbeek, P Pevenage, and J De Mey Influence of display quality on radiologists' performance in the detection of lung nodules on radiographs Br. J. Radiol., September 1, 2007; 80(957): 738 - 743. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. C. Brennan, M. McEntee, M. Evanoff, P. Phillips, W. T. O'Connor, and D. J. Manning Ambient Lighting: Effect of Illumination on Soft-Copy Viewing of Radiographs of the Wrist Am. J. Roentgenol., February 1, 2007; 188(2): W177 - W180. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. P. McAdams, E. Samei, J. Dobbins III, G. D. Tourassi, and C. E. Ravin Recent Advances in Chest Radiography Radiology, December 1, 2006; 241(3): 663 - 683. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |