Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print January 28, 2005, 10.1148/radiol.2343040020
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2343040020v1
234/3/934    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhao, B.
Right arrow Articles by Kalaigian, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhao, B.
Right arrow Articles by Kalaigian, J. P.
(Radiology 2005;234:934-939.)
© RSNA, 2005


Thoracic Imaging

Pulmonary Metastases: Effect of CT Section Thickness on Measurement—Initial Experience1

Binsheng Zhao, DSc, Lawrence H. Schwartz, MD, Chaya S. Moskowitz, PhD, Liang Wang, MD, Michelle S. Ginsberg, MD, Cathleen A. Cooper, BS, Li Jiang, MS and John P. Kalaigian, BS

1 From the Departments of Radiology (B.Z., L.H.S., L.W., M.S.G., C.A.C., L.J., J.P.K.) and Epidemiology and Biostatistics (C.S.M.), Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10021. Received January 7, 2004; revision requested March 9; revision received May 3; accepted June 2. Supported in part by grants from William H. Goodwin and Alice Goodwin and the Commonwealth Foundation for Cancer Research and The Experimental Therapeutics Center of Memorial Sloan-Kettering Cancer Center. Address correspondence to B.Z. (e-mail: zhaob@mskcc.org).

PURPOSE: To assess the effect of commonly used computed tomographic (CT) section thicknesses on metastatic tumor measurements calculated with unidimensional, bidimensional, area, and volumetric methods.

MATERIALS AND METHODS: Analysis and data collection were approved by the Institutional Review Board, with waived informed patient consent. Forty-two pulmonary metastases in 10 patients (three men and seven women; age range, 43–83 years; mean age, 65.4 years) were analyzed on CT scans obtained with 3.75-, 5.0-, and 7.5-mm section thicknesses. The lesions were automatically delineated by using a three-dimensional multicriteria segmentation algorithm. Unidimensional (the largest diameter), bidimensional (the product of the two maximal perpendicular diameters), maximal cross-sectional area, and volumetric measurements were automatically obtained for each pulmonary lesion on each section thickness. Means and variances were calculated, and the differences across the three section thicknesses for each of the four measurements were studied by using linear mixed-effects models. The Levene test was used to study the equality of variances.

RESULTS: Differences in the means for unidimensional, bidimensional, and area measurements were significant between a section thickness of 3.75 and 5.0 mm (unidimensional, P = .05; bidimensional, P = .05; area, P = .01) and 3.75 and 7.5 mm (unidimensional, P = .06; bidimensional, P = .03; area, P = .02), but not 5.0 and 7.5 mm. There was a significant difference in volumetric measurement as section thickness decreased from 7.5 to 5.0 mm (P <.001) and from 7.5 to 3.75 mm (P < .001). Although there was a slight trend for differences in the variances across section thickness for each measurement, none of the differences were significant.

CONCLUSION: Volumetric tumor measurements change with a reduction in section thickness from 7.5 to 5.0 and 3.75 mm. For unidimensional measurement, no change was found when thickness decreased from 7.5 to 5.0 mm.

© RSNA, 2005




This article has been cited by other articles:


Home page
RadiologyHome page
B. Zhao, L. P. James, C. S. Moskowitz, P. Guo, M. S. Ginsberg, R. A. Lefkowitz, Y. Qin, G. J. Riely, M. G. Kris, and L. H. Schwartz
Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non-Small Cell Lung Cancer
Radiology, July 1, 2009; 252(1): 263 - 272.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
P. J. Nietert, J. G. Ravenel, W. M. Leue, J. V. Miller, K. K. Taylor, E. S. Garrett-Mayer, and G. A. Silvestri
Imprecision in Automated Volume Measurements of Pulmonary Nodules and Its Effect on the Level of Uncertainty in Volume Doubling Time Estimation
Chest, June 1, 2009; 135(6): 1580 - 1587.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. A. Gavrielides, L. M. Kinnard, K. J. Myers, and N. Petrick
Noncalcified Lung Nodules: Volumetric Assessment with Thoracic CT
Radiology, April 1, 2009; 251(1): 26 - 37.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. G. Ravenel, W. M. Leue, P. J. Nietert, J. V. Miller, K. K. Taylor, and G. A. Silvestri
Pulmonary Nodule Volume: Effects of Reconstruction Parameters on Automated Measurements--A Phantom Study
Radiology, May 1, 2008; 247(2): 400 - 408.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Petrou, L. E. Quint, B. Nan, and L. H. Baker
Pulmonary Nodule Volumetric Measurement Variability as a Function of CT Slice Thickness and Nodule Morphology
Am. J. Roentgenol., February 1, 2007; 188(2): 306 - 312.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Zhao, L. H. Schwartz, C. S. Moskowitz, M. S. Ginsberg, N. A. Rizvi, and M. G. Kris
Lung Cancer: Computerized Quantification of Tumor Response--Initial Results
Radiology, December 1, 2006; 241(3): 892 - 898.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
C. C. Jaffe
Measures of Response: RECIST, WHO, and New Alternatives
J. Clin. Oncol., July 10, 2006; 24(20): 3245 - 3251.
[Abstract] [Full Text] [PDF]