Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2361040231
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zalis, M. E.
Right arrow Articles by Hahn, P. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zalis, M. E.
Right arrow Articles by Hahn, P. F.
(Radiology 2005;236:118-124.)
© RSNA, 2005


Experimental Studies

Polyp Size at CT Colonography after Electronic Subtraction Cleansing in an Anthropomorphic Colon Phantom1

Michael E. Zalis, MD, James J. Perumpillichira, MD, John Y. Kim, MD, MPH, Chiara Del Frate, MD2, Cordula Magee, PhD and Peter F. Hahn, MD, PhD

1 From the Division of Abdominal Imaging and Intervention, Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114. Received February 16, 2004; revision requested April 21; final revision received August 3; accepted September 20. Address correspondence to M.E.Z. (e-mail: mzalis{at}partners.org).

PURPOSE: To evaluate the effect of various bowel contrast material concentrations and subtraction software on size measurements of well-defined polyp lesions in a colon phantom at CT colonography.

MATERIALS AND METHODS: Repeated scanning and a precise reference standard required the use of a colon phantom in which 21 polyps were randomly distributed. Two readers who had each reviewed computed tomographic (CT) colonographic images from more than 100 cases evaluated polyp size on images obtained when the phantom was partially filled with varying concentrations of contrast material, scanned by using CT colonography, and subjected to electronic subtraction cleansing. The single largest dimension was recorded for each reader for a randomized series of polyps. These measurements were compared with a reference standard that was based on a combination of the manufacturer's polyp size specifications and the subsequent verification of these sizes by an independent consensus panel. Six weeks after initial observations, readers evaluated images of the phantom scanned without the presence of contrast material. Polyp size estimations for the two readers for each series were compared with the reference standard to obtain a mean absolute measurement error for each reader for each series. Data for each reader were compared by using a nonparametric Kruskal-Wallis analysis of variance test. A pair-wise comparison of the experimental and control series was then performed by using the Dunn post hoc test.

RESULTS: Contrast material dilutions resulting in an average attenuation of less than 500 HU resulted in complete subtraction and the absence of streak artifacts. There was no statistically significant difference between the average measurement error for contrast attenuations between 300 and 500 HU when compared with that of control. Streak artifact was noticeable for the highest dilution (mean, 840 HU). No statistically significant differences were observed for series in which cleansing software was used in the absence of bowel contrast material.

CONCLUSION: The combination of electronic cleansing and bowel contrast enhancement in the range of 300–500 HU results in no substantial change in readers' estimations of polyp size at CT colonography.

© RSNA, 2005




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
A. H. de Vries, H. W. Venema, J. Florie, C. Y. Nio, and J. Stoker
Influence of Tagged Fecal Material on Detectability of Colorectal Polyps at CT: Phantom Study
Am. J. Roentgenol., October 1, 2008; 191(4): W181 - W189.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Slater, S. A. Taylor, D. Burling, L. Gartner, J. Scarth, and S. Halligan
Colonic polyps: effect of attenuation of tagged fluid and viewing window on conspicuity and measurement--in vitro experiment with porcine colonic specimen.
Radiology, July 1, 2006; 240(1): 101 - 109.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. E. Zalis, J. J. Perumpillichira, C. Magee, G. Kohlberg, and P. F. Hahn
Tagging-based, Electronically Cleansed CT Colonography: Evaluation of Patient Comfort and Image Readability.
Radiology, April 1, 2006; 239(1): 149 - 159.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.