Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print June 13, 2005, 10.1148/radiol.2353040601
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2353040601v1
236/1/57    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Papavassiliu, T.
Right arrow Articles by van Rossum, A. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Papavassiliu, T.
Right arrow Articles by van Rossum, A. C.
(Radiology 2005;236:57-64.)
© RSNA, 2005


Cardiac Imaging

Effect of Endocardial Trabeculae on Left Ventricular Measurements and Measurement Reproducibility at Cardiovascular MR Imaging1

Theano Papavassiliu, MD, Harald P. Kühl, MD, Meike Schröder, MD, Tim Süselbeck, MD, Olga Bondarenko, MD, Christoph K. Böhm, MD, Aernout Beek, MD, Mark M. B. Hofman, PhD and Albert C. van Rossum, MD, PhD

1 From Medical Clinic I (T.P., T.S.) and Dept of Radiology (M.S., C.K.B.), Univ Hosp of Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany; and Dept of Cardiology, VU Univ Medical Ctr, Amsterdam, the Netherlands (H.P.K., O.B., A.B., M.M.B.H., A.C.v.R.). Received Apr 8, 2004; revision requested Jun 18; revision received Jul 30; accepted Aug 25. T.P. supported by a grant from the Medical Faculty of the Univ of Mannheim. H.P.K. supported in part by grants from the Medical Faculty of the Rheinisch-Wesfälische Technische Hochschule, Aachen, Germany, and the Grimmke-Stiftung, Düsseldorf, Germany. O.B. supported by grant 2001.158 from the Netherlands Heart Foundation. Address correspondence to T.P. (e-mail: theano.papavassilliu{at}med.ma.uni-heidelberg.de).

PURPOSE: To prospectively assess the effect of including or excluding endocardial trabeculae in left ventricular (LV) measurements and the reproducibility of these measurements at cine cardiovascular magnetic resonance (MR) imaging with true fast imaging with steady-state precession (FISP).

MATERIALS AND METHODS: The study was approved by the local ethics committee, and each subject gave informed consent before participating. Twenty healthy subjects and 20 consecutive patients underwent 1.5-T cardiovascular MR imaging. Seven to 12 short-axis views encompassing the entire LV were acquired by using true FISP. Endocardial and epicardial contours were traced manually. The data sets in each patient were analyzed twice: with inclusion of endocardial trabeculae in the LV cavity volume and with exclusion of endocardial trabeculae from the cavity volume. On the basis of these two contour sets, the end-diastolic (ED) and end-systolic (ES) LV volumes, ejection fraction (EF), and LV mass were calculated. Additionally, interobserver and interexamination reproducibility was assessed by using Bland-Altman analysis.

RESULTS: Compared with exclusion of trabeculae, inclusion of trabeculae in the LV cavity volume resulted in significantly larger ED and ES LV volumes (mean differences, 21 mL ± 11 [standard deviation] and 19 mL ± 33, respectively; P < .001) and lower EFs (mean difference, –2% ± 2; P < .001). The calculated LV mass was significantly smaller with inclusion than with exclusion of trabeculae (mean difference, –21 g ± 12; P < .001). All interobserver and interexamination limits of agreement based on inclusion of trabeculae, except those for EF measurements, were superior to those based on exclusion of trabeculae. At measurement reproducibility comparisons, differences in interobserver ED LV volume and LV mass and interexamination LV mass were statistically significant, favoring the inclusion of trabeculae in the LV cavity volume.

CONCLUSION: Trabeculae significantly affect quantifications of LV volume and mass. The superior reproducibility of LV measurements with the inclusion of endocardial trabeculae in the cavity volume favors this tracing algorithm for clinical use.

© RSNA, 2005




This article has been cited by other articles:


Home page
RadiologyHome page
S. Uribe, T. Tangchaoren, V. Parish, I. Wolf, R. Razavi, G. Greil, and T. Schaeffter
Volumetric Cardiac Quantification by Using 3D Dual-Phase Whole-Heart MR Imaging
Radiology, August 1, 2008; 248(2): 606 - 614.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
V. Mor-Avi, C. Jenkins, H. P. Kuhl, H.-J. Nesser, T. Marwick, A. Franke, C. Ebner, B. H. Freed, R. Steringer-Mascherbauer, H. Pollard, et al.
Real-Time 3-Dimensional Echocardiographic Quantification of Left Ventricular Volumes: Multicenter Study for Validation With Magnetic Resonance Imaging and Investigation of Sources of Error
J. Am. Coll. Cardiol. Img., July 1, 2008; 1(4): 413 - 423.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
M. Kankaanpaa, H.-R. Lehto, J. P. Parkka, M. Komu, A. Viljanen, E. Ferrannini, J. Knuuti, P. Nuutila, R. Parkkola, and P. Iozzo
Myocardial Triglyceride Content and Epicardial Fat Mass in Human Obesity: Relationship to Left Ventricular Function and Serum Free Fatty Acid Levels
J. Clin. Endocrinol. Metab., November 1, 2006; 91(11): 4689 - 4695.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.