Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2371041397
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van Laarhoven, H. W. M.
Right arrow Articles by Heerschap, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van Laarhoven, H. W. M.
Right arrow Articles by Heerschap, A.
(Radiology 2005;237:181-188.)
© RSNA, 2005


Gastrointestinal Imaging

Gadopentetate Dimeglumine and FDG Uptake in Liver Metastases of Colorectal Carcinoma as Determined with MR Imaging and PET1

Hanneke W. M. van Laarhoven, MD, MA, Lioe-Fee de Geus-Oei, MD, Bastiaan Wiering, MD, Jasper Lok, BSc, Mark Rijpkema, PhD2, Johannes H. A. M. Kaanders, MD, PhD, Paul F. M. Krabbe, PhD, Theo Ruers, MD, PhD, Cornelis J. A. Punt, MD, PhD, Albert J. van der Kogel, PhD, Wim J. G. Oyen, MD, PhD and Arend Heerschap, PhD

1 From the Departments of Medical Oncology (H.W.M.v.L., C.J.A.P.), Nuclear Medicine (L.F.d.G., W.J.G.O.), Surgery (B.W., T.R.), Radiation Oncology (J.L., J.H.A.M.K., A.J.v.d.K.), Radiology (M.R., A.H.), and Medical Technology Assessment (P.F.M.K.), University Medical Center Nijmegen, Geert Grooteplein 8, 6500 HB Nijmegen, the Netherlands. Received August 11, 2004; revision requested October 14; revision received December 1; accepted January 14, 2005. Supported by the Dutch Cancer Society, grant KUN 2000-2307. Address correspondence to H.W.M.v.L. (e-mail: h.vanlaarhoven{at}onco.umcn.nl).

PURPOSE: To examine the in vivo relationship between fluorine 18 fluorodeoxyglucose (FDG) uptake, as measured with positron emission tomography (PET), and functional tumor vasculature, as measured with dynamic contrast material–enhanced magnetic resonance (MR) imaging, in patients with liver metastases of colorectal cancer.

MATERIALS AND METHODS: All patients provided written informed consent, and the study was approved by the institutional review board. A total of 26 patients (12 men and 14 women; mean age, 59 years) who were suspected of having liver metastases of histologically proved colorectal cancer and underwent work-up for liver metastasectomy were included. Patients underwent whole-body FDG PET, and tumor-to-nontumor ratio of FDG uptake in metastases was calculated. Dynamic contrast-enhanced MR imaging was performed, and the rate constant kep (s–1) of gadopentetate dimeglumine uptake in metastases was determined. Pimonidazole was used to determine tumor hypoxia and vascular density of metastases. To assess the relationship between FDG uptake, rate constant kep of gadopentetate dimeglumine uptake, hypoxic fraction, and vascular density, the Pearson correlation coefficient was calculated.

RESULTS: Negative correlation between tumor-to-nontumor ratio of FDG uptake and rate constant kep was observed (r = –0.421, P = .082). No correlation between tumor hypoxia and tumor-to-nontumor ratio of FDG uptake or rate constant kep was found. A positive correlation was observed between vascular density and rate constant kep (r = 0.458, P = .034) but not between tumor-to-nontumor ratio of FDG uptake.

CONCLUSION: Negative correlation between tumor-to-nontumor ratio of FDG uptake and rate constant kep suggests that lower values of gadopentetate dimeglumine uptake imply an acutely reduced supply of oxygen, which necessitates a higher uptake of glucose to maintain tumor energy levels. The positive correlation of vascular density with rate constant kep, but not with tumor-to-nontumor ratio of FDG uptake, emphasizes the potential of dynamic contrast-enhanced MR imaging to enable measurement of tumor vascularity in vivo and its additional value compared with ex vivo methods.

© RSNA, 2005




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
S. Bisdas, K. Spicer, and Z. Rumboldt
Whole-Tumor Perfusion CT Parameters and Glucose Metabolism Measurements in Head and Neck Squamous Cell Carcinomas: A Pilot Study Using Combined Positron-Emission Tomography/CT Imaging
AJNR Am. J. Neuroradiol., August 1, 2008; 29(7): 1376 - 1381.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Miles, C. Keith, H. W. M. van Laarhoven, L.-F. de Geus-Oei, B. Wiering, J. Lok, M. Rijpkema, J. H. A. M. Kaanders, P. F. M. Krabbe, T. Ruers, et al.
Gadopentetate Dimeglumine and FDG Uptake in Liver Metastases
Radiology, October 1, 2006; 241(1): 319 - 320.
[Full Text] [PDF]


Home page
RadiologyHome page
A. H. Khandani and R. C. Semelka
Can the Relation between Gadopentetate Dimeglumine and FDG Uptake in Colorectal Liver Metastases Be Used Clinically?
Radiology, October 1, 2005; 237(1): 1 - 2.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.