Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print August 26, 2005, 10.1148/radiol.2363041220
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2363041220v1
237/1/213    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mulkens, T. H.
Right arrow Articles by Termote, J.-L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mulkens, T. H.
Right arrow Articles by Termote, J.-L.
(Radiology 2005;237:213-223.)
© RSNA, 2005


Medical Physics

Use of an Automatic Exposure Control Mechanism for Dose Optimization in Multi–Detector Row CT Examinations: Clinical Evaluation1

Tom H. Mulkens, MD, Patrick Bellinck, MD, Michel Baeyaert, MD, Dirk Ghysen, MD, Xavier Van Dijck, MD, Elvier Mussen, MD, Caroline Venstermans, MD and Jean-Luc Termote, MD

1 From the Department of Radiology, Heilig Hart Hospital, Kolveniersvest 20, B-2500 Lier, Belgium. Received February 12, 2004; revision requested September 14; revision received September 29; accepted November 4. Address correspondence to T.H.M. (e-mail: tom.mulkens{at}hhzhlier.be).

PURPOSE: To prospectively compare dose reduction and image quality achieved with an automatic exposure control system that is based on both angular (x-y axis) and z-axis tube current modulation with dose reduction and image quality achieved with an angular modulation system for multi–detector row computed tomography (CT).

MATERIALS AND METHODS: The study protocol was approved by the institutional review board, and oral informed consent was obtained. In two groups of 200 patients, five anatomic regions (ie, the thorax, abdomen-pelvis, abdomen-liver, lumbar spine, and cervical spine) were examined with this modulation system and a six-section multi–detector row CT scanner. Data from these patients were compared with data from 200 patients who were examined with an angular modulation system. Dose reduction by means of reduction of the mean effective tube current in 600 examinations, image noise in 200 examinations performed with each modulation system, and subjective image quality scores in 100 examinations per-formed with each modulation system were compared with Wilcoxon signed rank tests.

RESULTS: Mean dose reduction for the angular and z-axis tube current modulation system and for the angular modulation system was as follows: thorax, 20% and 14%, respectively; abdomen-liver, 38% and 18%, respectively; abdomen-pelvis, 32% and 26%, respectively; lumbar spine, 37% and 10%, respectively; and cervical spine, 68% and 16%, respectively. These differences were statistically significant (P < .05). There was no significant difference in image noise and mean image quality scores between modulation systems, with the exception of cervical spinal examinations (P < .001 for both), where the examinations with angular modulation resulted in better scores. There is good correlation between the mean effective tube current level and the body mass index of patients with the new modulation system. Correlation was as follows: thorax, 0.77; abdomen-pelvis, 0.83; abdomen-liver, 0.84; lumbar spine, 0.8; and cervical spine, 0.6. This correlation was not observed with the angular modulation system.

CONCLUSION: An automatic exposure control mechanism that is based on real-time anatomy-dependent tube current modulation delivers good image quality with a significantly reduced radiation dose.

© RSNA, 2005




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. Matsuoka, A. R. Hunsaker, R. R. Gill, I. B. Oliva, B. Trotman-Dickenson, F. L. Jacobson, and H. Hatabu
Vascular Enhancement and Image Quality of MDCT Pulmonary Angiography in 400 Cases: Comparison of Standard and Low Kilovoltage Settings
Am. J. Roentgenol., June 1, 2009; 192(6): 1651 - 1656.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Matsubara, K. Koshida, K. Ichikawa, M. Suzuki, T. Takata, T. Yamamoto, and O. Matsui
Misoperation of CT Automatic Tube Current Modulation Systems with Inappropriate Patient Centering: Phantom Studies
Am. J. Roentgenol., April 1, 2009; 192(4): 862 - 865.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J.S.P. Tan, K.-L. Tan, J.C.L. Lee, C.-M. Wan, J.-L. Leong, and L.-L. Chan
Comparison of Eye Lens Dose on Neuroimaging Protocols between 16- and 64-Section Multidetector CT: Achieving the Lowest Possible Dose
AJNR Am. J. Neuroradiol., February 1, 2009; 30(2): 373 - 377.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. A. Leswick, M. M. Hunt, S. T. Webster, and D. A. Fladeland
Thyroid Shields versus z-Axis Automatic Tube Current Modulation for Dose Reduction at Neck CT
Radiology, November 1, 2008; 249(2): 572 - 580.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. J. Phillips, D. L. Stella, W. M. Rozen, M. Ashton, and G. I. Taylor
Abdominal Wall CT Angiography: A Detailed Account of a Newly Established Preoperative Imaging Technique
Radiology, October 1, 2008; 249(1): 32 - 44.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. H. Lee, J. M. Goo, H. J. Ye, S.-J. Ye, C. M. Park, E. J. Chun, and J.-G. Im
Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice
RadioGraphics, September 1, 2008; 28(5): 1451 - 1459.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. M. Israel, S. Herlihy, A. N. Rubinowitz, D. Cornfeld, and J. Brink
Does a Combination of Dose Modulation with Fast Gantry Rotation Time Limit CT Image Quality?
Am. J. Roentgenol., July 1, 2008; 191(1): 140 - 144.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. B. Smith, W. P. Dillon, B. C. Lau, R. Gould, F. R. Verdun, E. B. Lopez, and M. Wintermark
Radiation Dose Reduction Strategy for CT Protocols: Successful Implementation in Neuroradiology Section
Radiology, May 1, 2008; 247(2): 499 - 506.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M.T. Russell, J.R. Fink, F. Rebeles, K. Kanal, M. Ramos, and Y. Anzai
Balancing Radiation Dose and Image Quality: Clinical Applications of Neck Volume CT
AJNR Am. J. Neuroradiol., April 1, 2008; 29(4): 727 - 731.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. A. Jaffe, T. T. Yoshizumi, G. I. Toncheva, G. Nguyen, L. M. Hurwitz, and R. C. Nelson
Early First-Trimester Fetal Radiation Dose Estimation in 16-MDCT Without and With Automated Tube Current Modulation
Am. J. Roentgenol., April 1, 2008; 190(4): 860 - 864.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Kubo, P.-J. P. Lin, W. Stiller, M. Takahashi, H.-U. Kauczor, Y. Ohno, and H. Hatabu
Radiation Dose Reduction in Chest CT: A Review
Am. J. Roentgenol., February 1, 2008; 190(2): 335 - 343.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. T. Schindera, R. C. Nelson, T. L. Toth, G. T. Nguyen, G. I. Toncheva, D. M. DeLong, and T. T. Yoshizumi
Effect of Patient Size on Radiation Dose for Abdominal MDCT with Automatic Tube Current Modulation: Phantom Study
Am. J. Roentgenol., February 1, 2008; 190(2): W100 - W105.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, I. Valenta, O. Gaemperli, O. Adda, V. Treyer, C. A. Wyss, P. Veit-Haibach, F. Tatsugami, G. K. von Schulthess, and P. A. Kaufmann
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Eur. Heart J., January 2, 2008; 29(2): 191 - 197.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Matsubara, K. Koshida, M. Suzuki, H. Tsujii, T. Yamamoto, and O. Matsui
Comparison between 3-D and z-axis automatic tube current modulation technique in multidetector-row CT
Radiat Prot Dosimetry, January 1, 2008; 128(1): 106 - 111.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Coursey, D. P. Frush, T. Yoshizumi, G. Toncheva, G. Nguyen, and S. B. Greenberg
Pediatric Chest MDCT Using Tube Current Modulation: Effect on Radiation Dose with Breast Shielding
Am. J. Roentgenol., January 1, 2008; 190(1): W54 - W61.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.B. Smith, W.P. Dillon, R. Gould, and M. Wintermark
Radiation Dose-Reduction Strategies for Neuroradiology CT Protocols
AJNR Am. J. Neuroradiol., October 1, 2007; 28(9): 1628 - 1632.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
T.H. Mulkens, P. Marchal, S. Daineffe, R. Salgado, P. Bellinck, B. t. Rijdt, B. Kegelaers, and J.-L. Termote
Comparison of Low-Dose With Standard-Dose Multidetector CT in Cervical Spine Trauma
AJNR Am. J. Neuroradiol., September 1, 2007; 28(8): 1444 - 1450.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A. Deetjen, S. Mollmann, G. Conradi, A. Rolf, A. Schmermund, C. W Hamm, and T. Dill
Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography
Heart, September 1, 2007; 93(9): 1040 - 1043.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K Fujii, T Aoyama, S Koyama, and C Kawaura
Comparative evaluation of organ and effective doses for paediatric patients with those for adults in chest and abdominal CT examinations
Br. J. Radiol., August 1, 2007; 80(956): 657 - 667.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. H. Mulkens, S. Daineffe, R. De Wijngaert, P. Bellinck, A. Leonard, G. Smet, and J.-L. Termote
Urinary Stone Disease: Comparison of Standard-Dose and Low-Dose with 4D MDCT Tube Current Modulation
Am. J. Roentgenol., February 1, 2007; 188(2): 553 - 562.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Namasivayam, M.K. Kalra, K.M. Pottala, S.M. Waldrop, and P.A. Hudgins
Optimization of Z-Axis Automatic Exposure Control for Multidetector Row CT Evaluation of Neck and Comparison with Fixed Tube Current Technique for Image Quality and Radiation Dose
AJNR Am. J. Neuroradiol., November 1, 2006; 27(10): 2221 - 2225.
[Abstract] [Full Text] [PDF]